Roberts Gorden HE40UT, HE20ST, HE50DL, HE45UT, HE30DL, HE50ST Standard Burner Specifications

Page 79

SECTION 18: SPECIFICATIONS

18.9 Burner Specifications

Figure 35: BLACKHEAT® HE Linear and U-tube Specifications

Reflector

End View

Side View

Fan

 

 

100 mm

 

Swirler*

 

 

 

 

241 mm

 

 

 

 

 

 

Burner Tube

 

 

348 mm

499 mm

Tube Length

 

 

 

 

 

 

 

Plan View

 

 

Damper

 

 

 

 

 

 

Tube Length

 

 

 

 

100 mm

 

 

Fan

 

Burner Tube

 

457 mm

 

 

 

Damper

 

Internal Swirler*

Fan Tube

U-Tube

 

 

*Swirler must always be located in Fan Tube.

 

 

18.9.1 Standard Burner Specifications

Models

 

HE15

HE20

HE25

HE30

HE35

HE40

HE45

HE50

 

 

 

 

 

 

 

 

 

 

Burner Airplate ID Number

 

515

505

513

502

500

501

500

506

 

 

 

 

 

 

 

 

 

 

Jet Numbers - Natural G20 & 25

 

#31

#28

5/32

#17

#12

#8

#3

#1

 

 

 

 

 

 

 

 

 

 

Jet Numbers - Propane/Butane

 

#47

#43

#39

#33

#31

3.2 mm

#29

#28

 

 

 

 

 

 

 

 

 

Gas Consumption**Natural G20 (m3/h)

1.43

1.91

2.38

2.86

3.36

3.81

4.29

4.77

 

 

 

 

 

 

 

 

 

 

Natural G25

(m3/h)

1.66

2.22

2.77

3.32

3.88

4.43

4.99

5.54

 

 

 

 

 

 

 

 

 

 

Propane

(m3/h)

0.56

0.75

0.94

1.13

1.32

1.51

1.69

1.88

 

[kgh]

[1.07]

[1.43]

[1.79]

[2.15]

[2.50]

[2.86]

[3.22]

[3.58]

 

 

 

 

 

 

 

 

 

 

Butane

(m3/h)

0.43

0.57

0.72

0.86

1.00

1.15

1.29

1.43

 

 

 

 

 

 

 

 

 

 

Governor Pressure Butane

(mbar)

20.4

20.4

19.7

19.7

19.7

19.7

20

20.9

 

 

 

 

 

 

 

 

 

 

Butane

(in wg)

8.1

8.2

7.9

7.9

7.9

7.9

8.0

8.4

 

 

 

 

 

 

 

 

 

 

Propane

(mbar)

28.4

27.1

26.9

26.6

26.9

26.9

27.4

26.9

 

 

 

 

 

 

 

 

 

 

Propane

(in wg)

11.4

10.9

10.8

10.7

10.8

10.8

11.0

10.8

 

 

 

 

 

 

 

 

 

Governor Pressure Natural G20 (mbar)

10.0

9.5

9.5

9.5

9.2

9.5

8.7

8.7

 

 

 

 

 

 

 

 

 

Natural G20 (in wg)

4.0

3.8

3.8

3.8

3.7

3.8

3.5

3.5

 

 

 

 

 

 

 

 

 

Natural G25 (mbar)

15.4

14.9

15.2

14.9

14.2

14.9

13.7

13.2

 

 

 

 

 

 

 

 

 

Natural G25 (in wg)

6.2

6.0

6.1

6.0

5.7

6.0

5.5

5.3

 

 

 

 

 

 

 

 

 

 

**Based on Gross Caloric Value.

73 of 73

Image 79
Contents Owner If you smell gasPage Roberts-Gordon Europe Limited Table of ContentsPage Table of Figures Bottom and Back Panel Label PlacementPage Product Approval Heater Safety Control Side Label Placement Low Level User Instructions Installer ResponsibilityNational Standards and Applicable Codes Clearances to Combustibles Model Clearances Data Linear and Double LinearHE40ST HE45ST HE50ST HE45ST HE50ST HE15ST HE30DLHE30UT HE15UTHE20UT HE25UTTUBE, Protective Grille TUBE, Opposite 45 TiltMajor Component Descriptions General Suspension Details Typical Suspension Details Linear Standard Parts List Linear & Double Linear Heater InstallationDescription Linear General Assembly Overview HE35ST HE40ST f HE15ST f HE20ST HE25ST fHE45ST HE50ST f Double Linear Standard Parts List Double Linear General Assembly Overview HE60DL HE70DL f HE30DL fClosed Burner Tube InstallationCoupling and Tube Assembly Open2 Coupling and Tube Assembly 1 Coupling and Tube AssemblyTighten slide bar as shown below Tube Clamp Package Installation Hanger Option a Option BFan Tube Weld Spot Coupling Tee Tube Standard Parts List Tube Heater InstallationLockwasher 6mm Blackheat HE Tube Assembly OverviewHE30UT HE35UT g HE15UT g HE20UT gHE45UT g Burner Tube and Fan Tube Installation U-tube Hanger PlacementU-tube Support Bracket Assembly Installation 1 Tube Clamp Package InstallationTube, Standard Tube, Opposite Orient coupling so that Impact block is U-tube Installation Tube InstallationReflector 02750303 Reflector Support Strap 03050000 Screw #8 x 3/4 Multiburner Configuration & Installation Typical Manifold Layout Linear and U-Tube Configuration Burner Installation Burner & FAN InstallationStandard Fan Assembly Linear & U-tube Fan Installation IP55 Fan Assembly1 Double Linear Fan Installation Double Linear Fan InstallationNon-Return Valve Condensate Drain AssemblyOptional Heater Accessories 2 Side Reflector Installation Reflector Side Extension Installation 1 Bracket InstallationStep Tube Cover InstallationDistance a Extension 2 Frame Shield Installation3 Grille Installation 2 Grille End Cap Installation3 Mesh Guard Connection Sports Hall Guard Installation2 Fastener Installation 1 Grille InstallationUndershield Installation Undershield Installation 10.6.1 Hanger InstallationAdjust Undershield Height Wall Mounting Hardware InstallationVenting and Fresh AIR Supply Air Supply Requirements Outside Combustion Air SupplyCommon Duct Air Supply with Flue ConfigurationsGAS Piping Correct Positions Incorrect Positions Wrong InstallationTypical External Wiring Diagram Linear or U-Tube WiringTypical External Wiring Diagram Multiburner Typical External Wiring Diagram Double Linear OptionInternal Wiring Diagram Tubing may still be hot Heater Lockout Indicator by ConnectorOperation and service OperationSystem Checks Heater Lockout Indicator by Volt Free ConnectorTesting Commissioning MultiburnerServicing Instructions Automatic Flame Control Unit Pressure SwitchMaintenance Checklist ElectrodeGas Line Vent PipeOutside Air Inlet TubesTroubleshooting U-Tube Troubleshooting Flow Chart Linear, Double LinearTroubleshooting Flow Chart Linear, Double Linear and U-Tube Troubleshooting Flow Chart MultiburnerTroubleshooting Flow Chart Multiburner Manometer 4 3 2 1 0 1 2 3 4 5 Manifold Gas Pressure SettingReplacement Parts V2 W3 Description Quantity Viewer Window Replacement Package P/NDoor Gasket Replacement Package P/N Gas Valve Replacement Package P/NSpecifications Double Linear Heater Linear HeaterTube Heater Standard Burner Specifications Burner SpecificationsModels HE15 HE20 HE25 HE30 HE35 HE40 HE45 HE50 Page Page Maintain Clearance Side Clearance below