Roberts Gorden HE20UT, HE20ST, HE50DL, HE45UT, HE30DL, HE50ST Double Linear Heater, Tube Heater

Page 78

BLACKHEAT® HE INSTALLATION OPERATION AND SERVICE MANUAL

18.6 Linear Heater

HE15ST

HE20ST

HE25ST

HE30ST

HE35ST

HE40ST

HE45ST

HE50ST

Input - Gross (kW)

15

20

25

30

35

40

45

50/51

Input - Net (kW)

13.5

18

22.5

27

31.5

36

40.5

45/46

 

 

 

 

 

 

 

 

 

Tube Length (mm)

6096

9144

9144

12192

12192

12192

15240

15240

 

 

 

 

 

 

 

 

 

Overall Heater Length (mm)

6887

9935

9935

12983

12983

13028

16076

16076

 

 

 

 

 

 

 

 

 

Weight (kg)

41

55

55

68

68

68

81

81

 

 

 

 

 

 

 

 

Heated Area (m2)

20-160

30-210

40-265

50-315

55-370 65-420

70-475

80-525

 

 

 

 

 

 

 

 

 

Minimum Installation Height (mm)

3500

3500

3500

3500

4600

5000

5000

5000

 

 

 

 

 

 

 

 

 

Recommended Installation Height

3500

3600

3900

4200

4800

5500

6700

7600

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18.7 Double Linear Heater

HE30DL

HE40DL

HE50DL

HE60DL

HE70DL

Input - Gross (kW)

30

40

50

60

70

Input - Net (kW)

27.5

36

45

54

63

 

 

 

 

 

 

Tube Length (mm)

12802

18898

18898

24994

24994

 

 

 

 

 

 

Overall Heater Length (mm)

13914

20010

20010

26106

26106

 

 

 

 

 

 

Weight (kg)

82

110

110

136

136

 

 

 

 

 

 

Heated Area (m2)

50-315

65-420

80-525

100-630

110-740

 

 

 

 

 

 

Minimum Installation Height (mm)

3500

3500

3500

3500

4600

 

 

 

 

 

 

Recommended Installation Height (mm)

3500

3600

3900

4200

4800

 

 

 

 

 

 

18.8 U-tube Heater

HE15UT

HE20UT

HE25UT

HE30UT

HE35UT

HE40UT

HE45UT

HE50UT

Input - Gross (kW)

15

20

25

30

35

40

45

50

Input - Net (kW)

13.5

18

22.5

27

31.5

36

40.5

45

 

 

 

 

 

 

 

 

 

Tube Length (mm)

3531

5055

5055

6579

6579

6579

8103

8103

 

 

 

 

 

 

 

 

 

Overall Heater Length (mm)

4048

5572

5572

7096

7096

7096

8620

8620

 

 

 

 

 

 

 

 

 

Weight (kg)

39

54

54

65

65

66

96

96

 

 

 

 

 

 

 

 

 

Heated Area (m2)

20-160

30-210

40-265

50-315

55-370

65-420

70-475

80-525

 

 

 

 

 

 

 

 

 

Minimum Installation Height (mm)

3500

3500

4000

4700

5000

5000

5000

5000

 

 

 

 

 

 

 

 

 

Recommended Installation Height (mm)

3500

3600

4000

4700

5000

5500

6700

7600

 

 

 

 

 

 

 

 

 

72 of 73

Image 78
Contents If you smell gas OwnerPage Table of Contents Roberts-Gordon Europe LimitedPage Bottom and Back Panel Label Placement Table of FiguresPage Product Approval Heater Safety Control Side Label Placement Installer Responsibility Low Level User InstructionsNational Standards and Applicable Codes Clearances to Combustibles Clearances Data Linear and Double Linear ModelHE40ST HE45ST HE50ST HE15ST HE30DL HE45ST HE50STHE25UT HE15UTHE20UT HE30UTTUBE, Opposite 45 Tilt TUBE, Protective GrilleMajor Component Descriptions General Suspension Details Typical Suspension Details Linear & Double Linear Heater Installation Linear Standard Parts ListDescription Linear General Assembly Overview HE15ST f HE20ST HE25ST f HE35ST HE40ST fHE45ST HE50ST f Double Linear Standard Parts List Double Linear General Assembly Overview HE30DL f HE60DL HE70DL fOpen Burner Tube InstallationCoupling and Tube Assembly Closed1 Coupling and Tube Assembly 2 Coupling and Tube AssemblyTighten slide bar as shown below Tube Clamp Package Installation Hanger Option B Option aFan Tube Weld Spot Coupling Tee Tube Heater Installation Tube Standard Parts ListLockwasher 6mm Tube Assembly Overview Blackheat HEHE15UT g HE20UT g HE30UT HE35UT gHE45UT g U-tube Hanger Placement Burner Tube and Fan Tube Installation1 Tube Clamp Package Installation U-tube Support Bracket Assembly InstallationTube, Standard Tube, Opposite Orient coupling so that Impact block is Tube Installation U-tube InstallationReflector 02750303 Reflector Support Strap 03050000 Screw #8 x 3/4 Multiburner Configuration & Installation Typical Manifold Layout Linear and U-Tube Configuration Burner & FAN Installation Burner InstallationStandard Fan Assembly IP55 Fan Assembly Linear & U-tube Fan InstallationDouble Linear Fan Installation 1 Double Linear Fan InstallationCondensate Drain Assembly Non-Return ValveOptional Heater Accessories Reflector Side Extension Installation 1 Bracket Installation 2 Side Reflector InstallationTube Cover Installation Step2 Frame Shield Installation Distance a Extension2 Grille End Cap Installation 3 Grille Installation1 Grille Installation Sports Hall Guard Installation2 Fastener Installation 3 Mesh Guard ConnectionUndershield Installation 10.6.1 Hanger Installation Undershield InstallationAdjust Undershield Height Hardware Installation Wall MountingVenting and Fresh AIR Supply Outside Combustion Air Supply Air Supply RequirementsAir Supply with Flue Configurations Common DuctGAS Piping Incorrect Positions Wrong Installation Correct PositionsWiring Typical External Wiring Diagram Linear or U-TubeTypical External Wiring Diagram Double Linear Option Typical External Wiring Diagram MultiburnerInternal Wiring Diagram Operation Heater Lockout Indicator by ConnectorOperation and service Tubing may still be hotCommissioning Multiburner Heater Lockout Indicator by Volt Free ConnectorTesting System ChecksServicing Instructions Electrode Pressure SwitchMaintenance Checklist Automatic Flame Control UnitTubes Vent PipeOutside Air Inlet Gas LineTroubleshooting Troubleshooting Flow Chart Linear, Double Linear U-TubeTroubleshooting Flow Chart Linear, Double Linear and U-Tube Chart Multiburner Troubleshooting FlowTroubleshooting Flow Chart Multiburner Manifold Gas Pressure Setting Manometer 4 3 2 1 0 1 2 3 4 5Replacement Parts V2 W3 Gas Valve Replacement Package P/N Viewer Window Replacement Package P/NDoor Gasket Replacement Package P/N Description QuantitySpecifications Linear Heater Double Linear HeaterTube Heater Burner Specifications Standard Burner SpecificationsModels HE15 HE20 HE25 HE30 HE35 HE40 HE45 HE50 Page Page Maintain Clearance Side Clearance below