10.7 Wall Mounting
Install wall mounting brackets at the height shown in the layout drawing provided by the estimator. Space wall mounting brackets and hangers as indicated by dimensions d, e and f in the relevant Layout Overview drawing for your heater. For Linear heaters see Page 15, Figure 19, for Double Linear heaters see Page 18, Figure 21 and for
10.7.1 Hardware Installation
The wall mounting brackets must be attached to a suitable wall through all mounting holes. Screw sizes less than M8 (5/16") may not be used. In order for the wall mounting brackets to adequately carry the weight of the heater, it must be installed with best building practice.
Model | Quantity of Wall | Model | Quantity of Wall | |
Mounting Brackets | Mounting Brackets | |||
|
| |||
HE15UT | 2 | HE15ST | 3 | |
HE20UT | 3 | HE20ST | 4 | |
HE25UT | 3 | HE25ST | 4 | |
HE30UT | 3 | HE30ST | 5 | |
HE35UT | 3 | HE35ST | 5 | |
HE40UT | 3 | HE40ST | 5 | |
HE45UT | 4 | HE45ST | 6 | |
HE50UT | 4 | HE50ST | 6 |
Figure 26: U-tube (Horizontal)
Figure 27: | Figure 28: Linear |
Burner must |
be below fan |
48 of 73 |