SECTION 6: LINEAR & DOUBLE LINEAR HEATER INSTALLATION
SECTION 6: LINEAR & DOUBLE LINEAR HEATER INSTALLATION
WARNING
Cut/Pinch Hazard
Wear protective gear during installation, operation and service.
Edges are sharp.
Failure to follow these instructions can result in injury.
The figures in this section provide a general overview of component placement in a Linear and Double Linear system. The location of some components such as supports and couplings is crucial for proper installation. Assemble the heater components as shown on Page 14, Figure 18.
For optional reflector configurations for linear heaters see Page 6, Figure 3 through Page 7, Figure 9. Install appropriate suspension hardware, beam clamps, chain or rod at predetermined locations. Adjustments of chain length will provide uniform pitch.
If any step is unclear, please contact Roberts-Gordon LLC at +44 (0)121 506 7700.
6.1 Linear Standard Parts List
|
|
|
|
|
|
|
|
|
|
Part No. | Description | HE15ST | HE20ST | HE25ST | HE30ST | HE35ST | HE40ST | HE45ST | HE50ST |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
033XXXXX | Burner Assembly (Input and Fuel Varies) | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
|
|
|
|
|
|
|
|
|
|
07260001 | Fan Package XP 1 | 1 | 1 | 1 | 1 | 1 | - | - | - |
|
|
|
|
|
|
|
|
|
|
07260002 | Fan Package XP 2 (optional) | - | - | - | - | - | - | - | - |
|
|
|
|
|
|
|
|
|
|
07260003 | Fan Package XP 3 | - | - | - | - | - | 1 | 1 | 1 |
|
|
|
|
|
|
|
|
|
|
07260051 | Fan Package 1 IP55 (optional)** | 1 | 1 | 1 | 1 | 1 | - | - | - |
|
|
|
|
|
|
|
|
|
|
07260052 | Fan Package 2 IP55 (optional)** | - | - | - | - | - | - | - | - |
|
|
|
|
|
|
|
|
|
|
07260053 | Fan Package 3 IP55 (optional)** | - | - | - | - | - | 1 | 1 | 1 |
|
|
|
|
|
|
|
|
|
|
03051100 | Burner Tube, 100 mm x 3048 mm | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
|
|
|
|
|
|
|
|
|
|
91409408 | Tube, 100 mm x 3048 mm | - | 1 | 1 | 2 | 2 | 2 | 3 | 3 |
|
|
|
|
|
|
|
|
|
|
S5127W | Fan Tube, 100 mm x 3048 mm, with 3048 mm Swirler | - | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
|
|
|
|
|
|
|
|
|
|
S5134W | Fan Tube, 100 mm x 3048 mm, with 2134 mm Swirler | 1 | - | - | - | - | - | - | - |
|
|
|
|
|
|
|
|
|
|
01329600 | Standard Coupling Assembly | 1 | 2 | 2 | 3 | 3 | 3 | 4 | 4 |
|
|
|
|
|
|
|
|
|
|
01329700 | Coupling Lock | 1 | 2 | 2 | 3 | 3 | 3 | 4 | 4 |
|
|
|
|
|
|
|
|
|
|
02750303 | Reflector, Aluminium, 2439 mm | 3 | 4 | 4 | 6 | 6 | 6 | 7 | 7 |
|
|
|
|
|
|
|
|
|
|
027503SS | Reflector, Stainless Steel, 2439 mm (Optional)* | 3 | 4 | 4 | 6 | 6 | 6 | 7 | 7 |
|
|
|
|
|
|
|
|
|
|
02750800 | Reflector End Cap, Aluminium | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
|
|
|
|
|
|
|
|
|
|
027508SH | Reflector End Cap, Stainless (Optional)* | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
|
|
|
|
|
|
|
|
|
|
03090100 | Tube and Reflector Hanger | 3 | 4 | 4 | 5 | 5 | 5 | 6 | 6 |
|
|
|
|
|
|
|
|
|
|
01318901 | Tube Clamp Package (including Nut, Washer & Bolt) | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
|
|
|
|
|
|
|
|
|
|
91908004 | Wire Form | 2 | 3 | 3 | 5 | 5 | 5 | 6 | 6 |
|
|
|
|
|
|
|
|
|
|
94320812 | Screw #8 x 3/4, (Goes with 03050000) | 4 | 6 | 6 | 10 | 10 | 10 | 12 | 12 |
|
|
|
|
|
|
|
|
|
|
03050000 | Reflector Support Strap | 2 | 3 | 3 | 5 | 5 | 5 | 6 | 6 |
|
|
|
|
|
|
|
|
|
|
E0007576 | Bow Shackle*** | 3 | 4 | 4 | 5 | 5 | 5 | 6 | 6 |
|
|
|
|
|
|
|
|
|
|
91107720 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
|
|
|
|
|
|
|
|
|
|
S7199K | Damper Flange Assembly (For use on Multiburner Systems) |
|
|
| 1 Per Heater |
|
|
| |
|
|
|
|
|
|
|
|
|
|
* PVC coating must be removed prior to installation.
**If an IP55 protected fan is required, this fan replaces 07260001, 07260002, or 07260003.
***Some models may receive
13 of 73