Heat & Glo LifeStyle 8000CF-OAK-IPI, 8000CFLP-OAKIPI Service Parts List, Stocked, At Depot

Page 59

C. Service Parts List

 

8000CF-OAK-IPI

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement

 

 

 

Stocked

parts for your appliance please provide model number and serial number. All parts listed

 

in this manual may be ordered from an authorized dealer.

 

 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

 

Log Set Assembly

 

LOGS-8OAK

Y

1

Log 1

 

SRV2057-720

 

2

Log 2

 

SRV2057-721

 

3

Log 3

 

SRV2057-722

 

4

Log 4

 

SRV2057-723

 

5

Log 5

 

SRV2057-724

 

6

Log 6

 

SRV2057-725

 

7

Heat Shield

 

385-290

 

8

Log Grate

 

2057-008

 

9

Burner NG

 

2057-009

Y

Burner LP

 

2057-010

Y

 

 

10

Base Refractory

 

SRV2057-123

 

11

Insulation Board / Sheetrock ledge

 

2059-117A

 

12

Glass Door Assembly

 

GLA-950TR

Y

13

Surround

 

2059-103

 

14

Surround Cover

 

2059-118

 

15

Junction Box

 

4021-013

Y

 

Battery Pack

 

593-594A

Y

 

Flue Restrictor

 

385-128

 

 

Gasket Assembly

 

 

 

 

Contains Vent, Seal Cap, Burner Neck, and Valve

 

385-402A

 

 

Plate Gaskets

 

 

 

 

 

 

 

 

 

Glass Latch Support

 

386-122A

Y

 

Ground Strap

Pre 002927628

2025-512

 

 

Post 002927628

N/A

 

 

 

 

 

Mineral Wool

 

050-721

 

 

Pilot Plate

 

2057-143

 

 

Touch Up Paint

 

TUP-GBK-12

 

 

Vermiculite Embers

 

MYSTIC-EMBERS

 

 

 

 

 

 

 

Conversion Kit NG

 

NGK-8TROAK-IPI

Y

 

Conversion Kit LP

 

LPK-8TROAK-IPI

Y

 

Regulator NG

 

NGK-DXV

Y

 

Regulator LP

 

LPK-DXV

Y

 

Pilot Orifice NG

Pre 002927628

446-505

Y

 

Post 002927628

593-528

Y

 

 

 

Pilot Orifice LP

Pre 002927628

446-517

Y

 

Post 002927628

593-527

Y

 

 

Additional service part numbers appear on following page.

Heat & Glo • 8000CF-OAK-IPI2059-900 Rev. R • 6/09

59

Image 59
Contents Hot glass will cause burns What to do if you smell gasHOT Surfaces Xxxxxxxx CongratulationsHomeowner Reference Information User Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsYour Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalGAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASAfter Fireplace is Lit Frequently Asked QuestionsIssue Solutions Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingEither cobrahead or SIT Typical Appliance System Getting StartedAny such action may cause a fire hazard Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsSelecting Appliance Location Framing and ClearancesClearances Minimum Framing DimensionsConstructing the Appliance Chase Combustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsCombustible Mantels Vent Termination Minimum Clearances Termination Locations= Vent Terminal = AIR Supply Inlet = Area Where Terminal is not PermittedUse of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyV1 Minimum H1 + H2 Maximum Vent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows V1 Minimum H1 MaximumV1 Min H1 Max V2 Min H2 Max V1 + V2 Min H1 + H2 Max Top Vent Horizontal Termination Three ElbowsVertical Top Vent ChartH1+ H2 V1+ V2 Minimum H1+ H2 Maximum Top Vent Vertical Termination Two ElbowsH1 Maximum V1 + Minimum Required Vent Clearances and FramingPipe Clearances to Combustibles Heat Shield Above First 900 ElbowNon-Combustible Wall Penetration Wall Penetration FramingCombustible Wall Penetration Pipe DVP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Attaching Sheetrock Ledges Temporary Access PanelAppliance Preparation Securing and Leveling the Appliance Installing the Fiberglass GasketChecking Pilot Plate Completing Grate Set-upAssemble Pipe Sections Installing Vent PipeAttach Vent to the Firebox Assembly Assemble Vent SectionsSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Rotate Seams for DisassemblyAssemble and Install Storm Collar Install Metal Roof FlashingHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapAnsi Z223.1 and CAN/CGA-B149 installation codes Install Horizontal Termination CapGas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntellifire Ignition System Wiring Optional Accessories RequirementsIntellifire Pilot Ignition IPI Wiring Diagram Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Ember Placement Install the Optional RefractoryInstall the Log Assembly Log Assembly LOGS-8OAKHeat & Glo 8000CF-OAK-IPI 2059-900 Rev. R 6/09 Air Shutter Settings Install the MeshInstall Trim and/or Surround Air Shutter SettingIntellifire Ignition System TroubleshootingSymptom Possible Cause Corrective Action Ues to spark, and main Location Inches Millimeters Appliance Dimension DiagramReference Materials DVP vent components Vent Components DiagramsHorizontal Termination Cap DVP-TRAPCOOL-ADD RF6M RF12MBEK DVP-BEK2 DVP-TRAPFL305 mm DVP-TB1Service Parts Log Set AssemblyAt Depot Service Parts ListStocked Valve Assembly Contact Information