Heat & Glo LifeStyle 8000CF-OAK-IPI, 8000CFLP-OAKIPI owner manual Electrical Service and Repair

Page 43

D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation.

 

 

 

 

 

I

 

INTERMITTENT

PLUG-IN

 

IGNITION MODULE

 

 

PILOT

 

3 VAC

 

 

 

IGNITOR

3V TRANSFORMER

 

 

 

 

 

 

 

 

 

 

ON/OFF

 

 

 

 

S

 

 

WALL

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

FLAME SPARKER/

 

 

 

 

 

 

 

SENSOR

 

 

 

 

 

 

IGNITION

 

 

 

 

 

 

 

MODULE

 

 

 

 

 

 

 

(3V)

 

 

 

 

 

 

 

 

 

 

 

 

WHT

 

 

 

 

BATTERY

 

 

ORG

 

VALVE

LOW VOLTAGE

 

BLACK

* GROUND TO

PACK

 

 

 

SEE NOTE 1

 

 

FIREPLACE

 

 

 

 

 

 

 

 

 

 

CHASSIS

 

 

REMOTE

 

RED

 

 

NEUTRAL

GROUND

CONTROL HOT

 

 

BRN

 

 

 

 

 

BRN

 

 

 

 

 

 

 

 

 

 

WHITE WIRE

 

 

 

 

 

 

 

CAN BE

 

 

 

ORG

 

 

 

PLUGGED

 

 

 

 

 

 

INTO ANY

 

 

 

GRN

BLACK WIRE CAN BE

OF #1-#5

 

 

PIGGYBACK

PLUGGED INTO ANY OF

LOCATIONS

 

 

 

 

#1 - #5 LOCATIONS

 

ON THE

 

 

ON/OFF SWITCH

 

 

ON THE HOT SIDE

 

NEUTRAL SIDE

TRANSFORMER

 

 

 

 

 

 

 

3 VAC

 

 

 

 

 

 

PLUG IN

 

 

 

 

 

 

 

 

 

 

VALVE

 

Figure 12.1 Intellifire Pilot Ignition (IPI) Wiring Diagram

 

 

 

 

 

Heat & Glo • 8000CF-OAK-IPI2059-900 Rev. R • 6/09

43

Image 43
Contents HOT Surfaces What to do if you smell gasHot glass will cause burns Homeowner Reference Information CongratulationsXxxxxxxx User Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalGAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASIssue Solutions Frequently Asked QuestionsAfter Fireplace is Lit Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingEither cobrahead or SIT Typical Appliance System Getting StartedAny such action may cause a fire hazard Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsSelecting Appliance Location Framing and ClearancesConstructing the Appliance Chase Minimum Framing DimensionsClearances Combustible Mantels Mantel and Wall ProjectionsCombustible Mantel Legs or Wall Projections Vent Termination Minimum Clearances Termination Locations= Vent Terminal = AIR Supply Inlet = Area Where Terminal is not PermittedUse of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyV1 Minimum H1 + H2 Maximum Vent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows V1 Minimum H1 MaximumV1 Min H1 Max V2 Min H2 Max V1 + V2 Min H1 + H2 Max Top Vent Horizontal Termination Three ElbowsVertical Top Vent ChartH1 Maximum V1 + Minimum Top Vent Vertical Termination Two ElbowsH1+ H2 V1+ V2 Minimum H1+ H2 Maximum Required Vent Clearances and FramingPipe Clearances to Combustibles Heat Shield Above First 900 ElbowCombustible Wall Penetration Wall Penetration FramingNon-Combustible Wall Penetration Pipe DVP Install the Ceiling FirestopFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Temporary Access PanelAttaching Sheetrock Ledges Securing and Leveling the Appliance Installing the Fiberglass GasketChecking Pilot Plate Completing Grate Set-upAssemble Pipe Sections Installing Vent PipeAttach Vent to the Firebox Assembly Assemble Vent SectionsSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Rotate Seams for DisassemblyAssemble and Install Storm Collar Install Metal Roof FlashingHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapAnsi Z223.1 and CAN/CGA-B149 installation codes Install Horizontal Termination CapGas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntellifire Ignition System Wiring Optional Accessories RequirementsIntellifire Pilot Ignition IPI Wiring Diagram Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Ember Placement Install the Optional RefractoryInstall the Log Assembly Log Assembly LOGS-8OAKHeat & Glo 8000CF-OAK-IPI 2059-900 Rev. R 6/09 Air Shutter Settings Install the MeshInstall Trim and/or Surround Air Shutter SettingSymptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Ues to spark, and main Reference Materials Appliance Dimension DiagramLocation Inches Millimeters DVP vent components Vent Components DiagramsHorizontal Termination Cap DVP-TRAPCOOL-ADD RF6M RF12MBEK DVP-BEK2 DVP-TRAPFL305 mm DVP-TB1Service Parts Log Set AssemblyStocked Service Parts ListAt Depot Valve Assembly Contact Information