Delkin Devices EI - 25-1 manual Replacing Major GAS Components, Replacing GAS Component Assembly

Page 28

EURO 25 -1

28

SERVICING - Continued

REPLACING MAJOR GAS COMPONENTS

If any of the major gas components need to be replaced, such as the pilot or the gas valve, we recommend replacing the complete gas component assembly. The assembly is designed to be quickly and easily replaced with minimal inconvenience to the customer. Once replaced, the service technician can repair the defective assembly safely and comfortably in his shop and with the right tools and test equipment.

REPLACING GAS COMPONENT ASSEMBLY

Disconnect electricity to the appliance.

Remove the glass door and the logs. (see installation section)

Remove the burner tray by loosening and removing the two mounting screws located next to the two back log locating tabs.

Shut of the gas to the appliance and disconnect the gas line to the appliance.

If the appliance has a remote switch or thermostat, disconnect their wires at the front of the valve. Mark the wires for reassembly.

Remove the firebox back, see “REPLACEMENT OF FAN” (Page 26)

Remove the four screws holding the gas component assembly plate to the appliance. Gently slide the assembly forward out of the firebox. Replacing the assembly is the reverse of the above instructions.

CHANGING MAIN BURNER ORIFICE

Remove the glass door, log set and the burner.

Use a ½” wrench to loosen the orifice.

Change the orifice.

Attach the new orifice.

Replace the burner and the log set.

Test fire the appliance with the glass door off and check for gas leaks.

Replace the glass door.

CONVERTIBLE PILOT ORIFICE

7/16”

(11 mm)

WRENCH

(HERE)

Image 28
Contents Euro 25 Page Introduction Euro 25 Table of Contents Safety Installation Codes SpecificationsHigh Altitude Installation General InformationAppliance Description & Dimensions Front View Surround Sparker Removable Control CoverInstallation Instructions Clearances to CombustiblesInstallation Instructions 15 ¼ 387 mm Precautions VentingVenting GAS ConnectionsSpill Switch is Connected to the Appliance FACTORY-WIRED Attachment of Fireplace SurroundPlacement of Brick Panels Glass DoorLOG Placement LOG Placement Euro 25 PIN Hole for LOG # Euro 25 For Your SAFETY, Read Before Lighting Initial Operation Operation InstructionsTemporary SHUT-DOWN Procedure START-UP ProcedureComplete SHUT-DOWN Procedure Maintenance Cleaning the ApplianceTroubleshooting Symptom ActionTroubleshooting Servicing Under Warranty Adjusting Primary AIRPilot Adjustment ServicingReplacement of FAN Valve ConnectionsReplacing GAS Component Assembly Replacing Major GAS ComponentsChanging Main Burner Orifice Convertible Pilot OrificePrecautions Appendix a½ to 7 ½ 15 ¼ 387 mm Vent Gasket Connector Kit BCV4-KIT or BCV5-KIT Sample Modification Warning Plate Sample Warning LabelInstallation Instructions Canadian Heating Product Model Montigo 28 SeriesFirehearth / Monterey Model Firesong 220 Series Gasglo Model GG 28 Series Archgard T-100 Series FMI Model 850 Series Important Information Natural GASArchgard Limited Warranty Replacement Parts for Euro Item # Description QTY UnitEuro 25 Warranty Registration Beatty Drive MISSION, B.C. Canada