EURO 25 | 30 |
APPENDIX A
EURO
INSTALLATION INTO VENTED GAS FIREPLACES
HOST GAS FIREPLACE PREPARATION
•The following procedures must be conducted by a qualified gas appliance installer.
•Double check the minimum firebox dimensions.
•Disconnect electrical power and gas supply.
•Remove the burner or sandpan, pilot, and all parts of the gas train assembly.
•Attach the Archgard modification warning plate (see sample, page 26) to the host fireplace label.
•Attach the warning label (see sample, page 26) provided with the EURO
•Remove or trim any baffles inside the firebox that may be obstructing the direct passage to the flue connector.
•Remove or trim any decorative facing or baffles inside the firebox that may interfere with the insertion of the EURO
WARNING: Do not cut or remove the firebox. The integrity of the firebox envelope must be maintain to prevent a possibility of a fire hazard. This warning does not apply to model specific tested and approved instructions provided by Archgard Industries Ltd.
SIDE VIEW