APPENDIX A

EURO 25-1- INSTRUCTIONS FOR

INSTALLATION INTO VENTED GAS FIREPLACES

HOST GAS FIREPLACE PREPARATION

The following procedures must be conducted by a qualified gas appliance installer.

Double check the minimum firebox dimensions.

Disconnect electrical power and gas supply.

Remove the burner or sandpan, pilot, and all parts of the gas train assembly.

Attach the Archgard modification warning plate (see sample, page 26) to the host fireplace label.

Attach the warning label (see sample, page 26) provided with the EURO 25-1 insert to the back of the firebox.

Remove or trim any baffles inside the firebox that may be obstructing the direct passage to the flue connector.

Remove or trim any decorative facing or baffles inside the firebox that may interfere with the insertion of the EURO 25-1 insert.

WARNING: Do not cut or remove the firebox. The integrity of the firebox envelope must be maintain to prevent a possibility of a fire hazard. This warning does not apply to model specific tested and approved instructions provided by Archgard Industries Ltd.

SIDE VIEW

4 ½” to 7 ½

15 ¼” (387 mm)

Image 30
Contents Euro 25 Page Introduction Euro 25 Table of Contents Safety High Altitude Installation Installation CodesSpecifications General InformationAppliance Description & Dimensions Front View Surround Sparker Removable Control CoverInstallation Instructions Clearances to CombustiblesInstallation Instructions 15 ¼ 387 mm Precautions VentingVenting GAS ConnectionsSpill Switch is Connected to the Appliance FACTORY-WIRED Attachment of Fireplace SurroundPlacement of Brick Panels Glass DoorLOG Placement LOG Placement Euro 25 PIN Hole for LOG # Euro 25 For Your SAFETY, Read Before Lighting Initial Operation Operation InstructionsSTART-UP Procedure Temporary SHUT-DOWN ProcedureComplete SHUT-DOWN Procedure Maintenance Cleaning the ApplianceTroubleshooting Symptom ActionTroubleshooting Pilot Adjustment Servicing Under WarrantyAdjusting Primary AIR ServicingReplacement of FAN Valve ConnectionsChanging Main Burner Orifice Replacing GAS Component AssemblyReplacing Major GAS Components Convertible Pilot OrificePrecautions Appendix a½ to 7 ½ 15 ¼ 387 mm Vent Gasket Connector Kit BCV4-KIT or BCV5-KIT Sample Modification Warning Plate Sample Warning LabelInstallation Instructions Canadian Heating Product Model Montigo 28 SeriesFirehearth / Monterey Model Firesong 220 Series Gasglo Model GG 28 Series Archgard T-100 Series FMI Model 850 Series Important Information Natural GASArchgard Limited Warranty Replacement Parts for Euro Item # Description QTY UnitEuro 25 Warranty Registration Beatty Drive MISSION, B.C. Canada