Delkin Devices EI - 25-1 manual Archgard T-100 Series

Page 36

EURO 25 -1

36

INSTALLATION INSTRUCTIONS

INSTALLING THE EURO 25-1 GAS FIREPLACE INSERT HEATING APPLIANCE

INTO VENTED ZERO-CLEARANCE GAS FIREPLACE:

ARCHGARD T-100 SERIES

CAUTION: Installation must be conducted by a qualified gas appliance installer. Gas and electrical power must be disconnected from the host gas fireplace before installation can begin.

1.Remove the louvers and screens or glass door.

2.Remove the burner/sandpan assembly, valve and pilot assembly from the firebox bottom plate. Flip the plate over and leave the plate in place to support the gas insert.

3.Remove the facing cross members with an abrasive cutting disc or plasma cutter.

4.Remove the front top baffle with an abrasive cutting disc or plasma cutter.

5.Remove the flue deflector with a pair of sheet metal snips.

6.Replace the top louver.

7.The preparation of the host gas fireplace is complete. See Appendix A of the Euro-25-1 manual for further instructions. All installation requirements in the manual must also be carefully observed and followed.

8.Use Archgard BCV5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.

REMOVE CUT

ITEM 3.

ITEM 4.

CUT

ITEM 5.

Image 36
Contents Euro 25 Page Introduction Euro 25 Table of Contents Safety Installation Codes SpecificationsHigh Altitude Installation General InformationAppliance Description & Dimensions Front View Surround Sparker Removable Control CoverInstallation Instructions Clearances to CombustiblesInstallation Instructions 15 ¼ 387 mm Precautions VentingVenting GAS ConnectionsSpill Switch is Connected to the Appliance FACTORY-WIRED Attachment of Fireplace SurroundPlacement of Brick Panels Glass DoorLOG Placement LOG Placement Euro 25 PIN Hole for LOG # Euro 25 For Your SAFETY, Read Before Lighting Initial Operation Operation InstructionsSTART-UP Procedure Temporary SHUT-DOWN ProcedureComplete SHUT-DOWN Procedure Maintenance Cleaning the ApplianceTroubleshooting Symptom ActionTroubleshooting Servicing Under Warranty Adjusting Primary AIRPilot Adjustment ServicingReplacement of FAN Valve ConnectionsReplacing GAS Component Assembly Replacing Major GAS ComponentsChanging Main Burner Orifice Convertible Pilot OrificePrecautions Appendix a½ to 7 ½ 15 ¼ 387 mm Vent Gasket Connector Kit BCV4-KIT or BCV5-KIT Sample Modification Warning Plate Sample Warning LabelInstallation Instructions Canadian Heating Product Model Montigo 28 SeriesFirehearth / Monterey Model Firesong 220 Series Gasglo Model GG 28 Series Archgard T-100 Series FMI Model 850 Series Important Information Natural GASArchgard Limited Warranty Replacement Parts for Euro Item # Description QTY UnitEuro 25 Warranty Registration Beatty Drive MISSION, B.C. Canada