Delkin Devices EI - 25-1 manual Firehearth / Monterey Model Firesong 220 Series

Page 34

EURO 25 -1

34

INSTALLATION INSTRUCTIONS

INSTALLING THE EURO 25-1 GAS FIREPLACE INSERT HEATING APPLIANCE

INTO VENTED ZERO-CLEARANCE GAS FIREPLACE:

FIREHEARTH / MONTEREY MODEL FIRESONG 220 SERIES

CAUTION: Installation must be conducted by a qualified gas appliance installer. Gas and electrical power must be disconnected from the host gas fireplace before installation can begin.

1.Unhook the screen rod at the center and remove screens or glass door.

2.Unscrew and remove the front trim strip at the front of the firebox bottom.

3.Remove the burner/sandpan assembly, valve and pilot assembly from the firebox bottom plate. Leave the plate in place to support the gas insert.

4.Bend the front deflector plate forward and up. Measure the height of the front opening. The opening must be 15 ¼” of higher.

5.The preparation of the host gas fireplace is complete. See Appendix A of the Euro-25-1 manual for further instructions. All installation requirements in the manual must also be carefully observed and followed.

6.Use Archgard BCV5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.

BEND

TO

15 ¼

ITEM 4.

ITEM 2.

Image 34
Contents Euro 25 Page Introduction Euro 25 Table of Contents Safety High Altitude Installation Installation CodesSpecifications General InformationAppliance Description & Dimensions Front View Surround Sparker Removable Control CoverInstallation Instructions Clearances to CombustiblesInstallation Instructions 15 ¼ 387 mm Precautions VentingVenting GAS ConnectionsSpill Switch is Connected to the Appliance FACTORY-WIRED Attachment of Fireplace SurroundPlacement of Brick Panels Glass DoorLOG Placement LOG Placement Euro 25 PIN Hole for LOG # Euro 25 For Your SAFETY, Read Before Lighting Initial Operation Operation InstructionsTemporary SHUT-DOWN Procedure START-UP ProcedureComplete SHUT-DOWN Procedure Maintenance Cleaning the ApplianceTroubleshooting Symptom ActionTroubleshooting Pilot Adjustment Servicing Under WarrantyAdjusting Primary AIR ServicingReplacement of FAN Valve ConnectionsChanging Main Burner Orifice Replacing GAS Component AssemblyReplacing Major GAS Components Convertible Pilot OrificePrecautions Appendix a½ to 7 ½ 15 ¼ 387 mm Vent Gasket Connector Kit BCV4-KIT or BCV5-KIT Sample Modification Warning Plate Sample Warning LabelInstallation Instructions Canadian Heating Product Model Montigo 28 SeriesFirehearth / Monterey Model Firesong 220 Series Gasglo Model GG 28 Series Archgard T-100 Series FMI Model 850 Series Important Information Natural GASArchgard Limited Warranty Replacement Parts for Euro Item # Description QTY UnitEuro 25 Warranty Registration Beatty Drive MISSION, B.C. Canada