Delkin Devices EI - 25-1 manual Installation Instructions

Page 33

EURO 25 -1

33

INSTALLATION INSTRUCTIONS

INSTALLING THE EURO 25-1 GAS FIREPLACE INSERT HEATING APPLIANCE

INTO VENTED ZERO-CLEARANCE GAS FIREPLACE:

CANADIAN HEATING PRODUCT MODEL MONTIGO 28 SERIES

CAUTION: Installation must be conducted by a qualified gas appliance installer. Gas and electrical power must be disconnected from the host gas fireplace before installation can begin.

1.Remove the louvers and screens or glass door.

2.Remove the burner/sandpan assembly, valve and pilot assembly from the firebox bottom plate. Leave the plate in place to support the gas insert.

3.Remove the bottom front trim.

4.Push the deflector at the back of the firebox against the back of the firebox until it is fairly flat against the back.

5.Bend the two front deflector plates forward and up. Measure the height of the front opening. The opening must be 15 ¼” or higher.

6.The preparation of the host gas fireplace is complete. See Appendix A of the Euro-25-1 manual for further instructions. All installation requirements in the manual must also be carefully observed and followed.

7.Use Archgard BCV5 connector kit to connect the insert to the host’s B-vent or connect a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.

*Optional custom surround is available for the Montigo 28 Series, Part # M28-BP-25. With this part, minimal finishing work is required. It will fill in the opening around the insert. The top louver of the Montigo is maintained. Please contact Archgard Industries for the availability of this part.

BEND TO

ITEM 4.

ITEM 3.

 

TO

 

BEND

15 ¼

 

 

 

 

ITEM 5.

Image 33
Contents Euro 25 Page Introduction Euro 25 Table of Contents Safety Specifications Installation CodesHigh Altitude Installation General InformationFront View Surround Sparker Removable Control Cover Appliance Description & DimensionsClearances to Combustibles Installation InstructionsInstallation Instructions 15 ¼ 387 mm Venting PrecautionsGAS Connections VentingAttachment of Fireplace Surround Spill Switch is Connected to the Appliance FACTORY-WIREDGlass Door Placement of Brick PanelsLOG Placement LOG Placement Euro 25 PIN Hole for LOG # Euro 25 Operation Instructions For Your SAFETY, Read Before Lighting Initial OperationSTART-UP Procedure Temporary SHUT-DOWN ProcedureComplete SHUT-DOWN Procedure Cleaning the Appliance MaintenanceSymptom Action TroubleshootingTroubleshooting Adjusting Primary AIR Servicing Under WarrantyPilot Adjustment ServicingValve Connections Replacement of FANReplacing Major GAS Components Replacing GAS Component AssemblyChanging Main Burner Orifice Convertible Pilot OrificeAppendix a Precautions½ to 7 ½ 15 ¼ 387 mm Vent Gasket Connector Kit BCV4-KIT or BCV5-KIT Sample Warning Label Sample Modification Warning PlateCanadian Heating Product Model Montigo 28 Series Installation InstructionsFirehearth / Monterey Model Firesong 220 Series Gasglo Model GG 28 Series Archgard T-100 Series FMI Model 850 Series Natural GAS Important InformationArchgard Limited Warranty Item # Description QTY Unit Replacement Parts for EuroEuro 25 Warranty Registration Beatty Drive MISSION, B.C. Canada