GENERAL INFORMATION

APPLIANCE CERTIFICATION

This appliance is tested and certified to the following U.S. and Canadian gas appliance standards.

-ANSI Z 21.88b-2003 / CSA 2.33b-2003, Vented Gas Fireplace Heater

-CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes.

Please contact Archgard Industries Ltd., if you have any questions regarding the certification of these appliances.

INSTALLATION CODES

This appliance must be installed by a qualified gas appliance installer. The installation must conform with the local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code, CAN/CGA-B149, in Canada. Electrical connections and grounding must conform with local code, or current National Electrical code, ANSI/NFPA No. 54, in the U.S. and in Canada, the current Canadian Electrical Code, CSA C22.1. This appliance is certified for installation in a bedroom or a bedsitting room and conforms to CR89-001.

SPECIFICATIONS

 

Natural Gas (NG)

Propane (LP)

 

 

 

Manifold Pressure

1.7 - 3.5 in. w.c. (0.4 - 0.9 kPa)

6.3 - 10.0 in. w.c. (1.6 - 2.5 kPa)

 

 

 

Minimum Supply Pressure for

4.5 in. w.c. (1.2 kPa)

11.0 in. w.c. (2.8 kPa)

Purpose of Input Adjustment

 

 

Maximum Supply Pressure for

14.0 in. w.c. (3.6 kPa)

14.0 in. w.c. (3.6 kPa)

Purpose of Input Adjustment

 

 

Orifice Size

Cap #45 DMS (2.08 mm dia.)

Cap #55 DMS (1.32 mm dia.)

 

 

 

Nominal Input Rating

15,000 - 20,000 BTU/hr (4.4 - 5.8 kW)

16,000 -20,000 BTU/hr (4.6 - 5.8 kW)

 

 

 

Altitude

0 - 4,500 ft. (0 - 1372 m)

0 - 4,500 ft. (0 - 1372 m)

 

 

 

Primary Air Opening

3/16 in. (5 mm)

Fully Open

 

 

 

HIGH ALTITUDE INSTALLATION

When installing this appliance beyond 4500 ft. (1372 m) above sea level, the appliance must be properly de-rated and installed according to local codes, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the U.S. or Installation Code, CAN/CGA-B149, in Canada.

Image 7
Contents Euro 25 Page Introduction Euro 25 Table of Contents Safety General Information Installation CodesSpecifications High Altitude InstallationFront View Surround Sparker Removable Control Cover Appliance Description & DimensionsClearances to Combustibles Installation InstructionsInstallation Instructions 15 ¼ 387 mm Venting PrecautionsGAS Connections VentingAttachment of Fireplace Surround Spill Switch is Connected to the Appliance FACTORY-WIREDGlass Door Placement of Brick PanelsLOG Placement LOG Placement Euro 25 PIN Hole for LOG # Euro 25 Operation Instructions For Your SAFETY, Read Before Lighting Initial OperationTemporary SHUT-DOWN Procedure START-UP ProcedureComplete SHUT-DOWN Procedure Cleaning the Appliance MaintenanceSymptom Action TroubleshootingTroubleshooting Servicing Servicing Under WarrantyAdjusting Primary AIR Pilot AdjustmentValve Connections Replacement of FANConvertible Pilot Orifice Replacing GAS Component AssemblyReplacing Major GAS Components Changing Main Burner OrificeAppendix a Precautions½ to 7 ½ 15 ¼ 387 mm Vent Gasket Connector Kit BCV4-KIT or BCV5-KIT Sample Warning Label Sample Modification Warning PlateCanadian Heating Product Model Montigo 28 Series Installation InstructionsFirehearth / Monterey Model Firesong 220 Series Gasglo Model GG 28 Series Archgard T-100 Series FMI Model 850 Series Natural GAS Important InformationArchgard Limited Warranty Item # Description QTY Unit Replacement Parts for EuroEuro 25 Warranty Registration Beatty Drive MISSION, B.C. Canada