EURO 25 | 7 |
GENERAL INFORMATION
APPLIANCE CERTIFICATION
This appliance is tested and certified to the following U.S. and Canadian gas appliance standards.
-ANSI Z
-
Please contact Archgard Industries Ltd., if you have any questions regarding the certification of these appliances.
INSTALLATION CODES
This appliance must be installed by a qualified gas appliance installer. The installation must conform with the local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code,
SPECIFICATIONS
| Natural Gas (NG) | Propane (LP) |
|
|
|
Manifold Pressure | 1.7 - 3.5 in. w.c. (0.4 - 0.9 kPa) | 6.3 - 10.0 in. w.c. (1.6 - 2.5 kPa) |
|
|
|
Minimum Supply Pressure for | 4.5 in. w.c. (1.2 kPa) | 11.0 in. w.c. (2.8 kPa) |
Purpose of Input Adjustment |
|
|
Maximum Supply Pressure for | 14.0 in. w.c. (3.6 kPa) | 14.0 in. w.c. (3.6 kPa) |
Purpose of Input Adjustment |
|
|
Orifice Size | Cap #45 DMS (2.08 mm dia.) | Cap #55 DMS (1.32 mm dia.) |
|
|
|
Nominal Input Rating | 15,000 - 20,000 BTU/hr (4.4 - 5.8 kW) | 16,000 |
|
|
|
Altitude | 0 - 4,500 ft. (0 - 1372 m) | 0 - 4,500 ft. (0 - 1372 m) |
|
|
|
Primary Air Opening | 3/16 in. (5 mm) | Fully Open |
|
|
|
HIGH ALTITUDE INSTALLATION
When installing this appliance beyond 4500 ft. (1372 m) above sea level, the appliance must be properly