Desa LEN) (V)L32(HP, LZPR) Variable Control Operation, To Turn OFF GAS To Appliance

Page 23

OPERATING FIREPLACE

Continued

VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired, by sim- ply turning the control knob until that setting is attained. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher settings produces greater heat output. This results in increased heating comfort.

WARNING: Do not operate heater between locked positions.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Press in and turn control knob clockwise to the HI position.

2.Turn the control knob clockwise to the PILOT position.

3.Press in control knob and turn clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

1.Turn the control knob clockwise to the HI position.

2.Press in and turn control knob clockwise to the PILOT position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 22.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, column 2, page 22.

REMOTE-READY MODELS

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

115254-01A

www.desatech.com

23

Image 23
Contents VL36EP, LEP VL32HN, LHNVL36EN, LEN VL32HP, LHPTable of Contents Safety Information Operation Product FeaturesBlower Accessory Local CodesModels Product SpecificationsLocating Firebox Planning42 Models Determining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation Air From Inside Building Ventilation AIRMinimum Wall and Ceiling Clearances see , InstallationInstallation Clearances Ventilation Air From OutdoorsMinimum 16 inches from Side Wall BUILT-IN Firebox InstallationExample Nails or Wood Screws Nailing Flanges Rough Opening for Installing WallInstalling Cabinet Mantel Installing Firebox Using Optional Accessory MantelsDuplex Electrical Outlet Installing Optional Blower AccessoriesLower Louver Panel Place control knob, provided, onto control shaft see Figure Wiring Diagram Decal 12 Front of BlowerTop View of Rod Layout HARD-WIRING FireboxInstalling Fireplace Hood and Screen Duplex Box Handy Box Strain ReliefVent Pointing Down Connecting to GAS SupplyInstallation Items Needed Natural Checking GAS ConnectionsPropane/LP Correct all leaks at once Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Supply TankChassis Post Installing LogsVintage Oak Two-Piece Log Set Log #2 Log #1 Front PostMetal Post Ember Bed Base AssemblyMetal PostLeft Front Log Right Front Log Operating FireplacePlace top left log on middle log as shown in Figure Top Left Log Top Right Log MiddleButton Lighting InstructionsPress in control knob and turn counter Control Knob IgnitorTo Turn OFF GAS To Appliance Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting Variable Control OperationBe hot if heater has been running Optional HAND-HELD Remote Operation Follow instructions included with the remote controlControl Knob Flame Adjustment On Position Optional Remote ControlThermostat Series Model Ghrctb ON/OFF Series Model GhrcbFront Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceCleaning Logs Observed Problem Possible Cause Remedy TroubleshootingLong enough Clean ODS/pilot seeLow gas pressure Assembly LeasedBustion Damaged When burners are lit Position when burners areObserve minimum installa Burner backfiring during comGas leak. See Warning REMOTE-READY Models only SpecificationsWiring Diagram Maximum Minimum Shipping Weight 104 lbs 184 lbsParts Under Warranty Service HintsTechnical Service Replacement PartsAccessories Illustrated Parts Breakdown Parts Available not Shown Parts List46 39 Parts List 23/24 Not Shown 110314-05 Crossover Log Illustrated Parts Breakdown and Parts ListKEY LOG Part Numbers VL36 Models VL42 Models Description QTY Limited Warranty VENT-FREE Fireplace Warranty InformationKeep this Warranty