Desa LEN) (V)L32(HP Leased, Long enough, Seconds, Been triggered, Ignition operation, Els Only

Page 30

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

ODS/pilot lights but flame goes

1. Control knob not fully

1.

Press in control knob fully

out when control knob is re-

 

pressed in

2.

After ODS/pilot lights, keep

leased

2. Control knob not pressed in

 

 

long enough

 

control knob pressed in 30

 

3.

Safety interlock system has

 

seconds

 

3.

Wait one minute for safety in-

 

 

been triggered

 

terlock system to reset. Repeat

 

4.

Equipment shutoff valve not

 

ignition operation

 

4.

Fully open equipment shutoff

 

 

fully open

 

valve

 

5.

Pilot flame not touching

5.

A) Contact local natural or

 

 

thermocouple, which allows

 

propane/LP gas company

 

 

thermocouple to cool, caus-

 

 

 

 

ing pilot flame to go out. This

 

B) Clean ODS/pilot (see

 

 

problem could be caused by

 

Cleaning and Maintenance,

 

 

one or both of the following:

 

page 28) or replace ODS/pilot

 

 

A) Low gas pressure

 

assembly

 

 

B) Dirty or partially clogged

 

 

 

 

ODS/pilot

 

 

 

6.

Thermocouple connection

6.

Hand tighten until snug, then

 

 

loose at control valve

 

tighten 1/4 turn more

 

7.

Thermocouple damaged

7.

Replace pilot assembly

 

8.

Control valve damaged

8.

Replace control valve

 

 

 

 

One or both burners do not light

1. Inlet gas pressure is too low

1.

Contact local natural or pro-

after ODS/pilot is lit

2.

Burner orifice(s) clogged

 

pane/LP gas company

 

2.

Clean burner(s) (see Cleaning

 

 

 

 

and Maintenance, page 28) or

 

3.

Mislocated crossover tube

 

replace burner orifice(s)

 

3.

Contact qualified service person

 

4.

Remoteselector in OFF position

4.

Put remote selector in ON

 

 

(Remote-Ready Models Only)

 

position

 

5.

Wire disconnected from gas

5.

See Wiring Diagram, page 33

 

 

control (Remote-Ready Mod-

 

 

 

 

els Only)

 

 

 

 

 

 

Delayed ignition of one or both

1. Manifold pressure is too low

1.

Contact local natural or pro-

burners

2.

Burner orifice(s) clogged

 

pane/LP gas company

 

2.

Clean burner(s) (see Cleaning

 

 

 

 

and Maintenance, page 28) or

 

3.

Mislocated crossover tube

 

replace burner orifice(s)

 

3.

Contact qualified service

 

 

 

 

person

30

www.desatech.com

115254-01A

Image 30
Contents VL32HP, LHP VL32HN, LHNVL36EN, LEN VL36EP, LEPTable of Contents Safety Information Local Codes Product FeaturesBlower Accessory OperationPlanning Product SpecificationsLocating Firebox Models42 Models AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors InstallationInstallation Clearances Minimum Wall and Ceiling Clearances see ,BUILT-IN Firebox Installation ExampleMinimum 16 inches from Side Wall Rough Opening for Installing Wall Nails or Wood Screws Nailing FlangesInstalling Firebox Using Optional Accessory Mantels Installing Cabinet MantelInstalling Optional Blower Accessories Lower Louver PanelDuplex Electrical Outlet Wiring Diagram Decal 12 Front of Blower Place control knob, provided, onto control shaft see FigureDuplex Box Handy Box Strain Relief HARD-WIRING FireboxInstalling Fireplace Hood and Screen Top View of Rod LayoutConnecting to GAS Supply Installation Items NeededVent Pointing Down Checking GAS Connections Propane/LPNatural Supply Tank Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Correct all leaks at onceLog #2 Log #1 Front Post Installing LogsVintage Oak Two-Piece Log Set Chassis PostPost Ember Bed Base AssemblyMetal Metal PostTop Left Log Top Right Log Middle Operating FireplacePlace top left log on middle log as shown in Figure Left Front Log Right Front LogControl Knob Ignitor Lighting InstructionsPress in control knob and turn counter ButtonVariable Control Operation Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting To Turn OFF GAS To ApplianceBe hot if heater has been running Optional Remote Control Follow instructions included with the remote controlControl Knob Flame Adjustment On Position Optional HAND-HELD Remote OperationON/OFF Series Model Ghrcb Thermostat Series Model GhrctbInspecting Burners Pilot Flame PatternFront Burner Flame Pattern Cleaning Maintenance Cleaning LogsBurner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyLeased Clean ODS/pilot seeLow gas pressure Assembly Long enoughBurner backfiring during com When burners are lit Position when burners areObserve minimum installa Bustion DamagedGas leak. See Warning Maximum Minimum Shipping Weight 104 lbs 184 lbs SpecificationsWiring Diagram REMOTE-READY Models onlyReplacement Parts Service HintsTechnical Service Parts Under WarrantyAccessories Illustrated Parts Breakdown Parts List Parts Available not Shown46 39 Parts List 23/24 Not Shown Illustrated Parts Breakdown and Parts List 110314-05 Crossover LogKEY LOG Part Numbers VL36 Models VL42 Models Description QTY Warranty Information Keep this WarrantyLimited Warranty VENT-FREE Fireplace