Desa LZPR) Cleaning Maintenance, Burner Injector Holder and Pilot AIR Inlet Hole, Cleaning Logs

Page 28

CLEANING AND

MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burners and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (see Figure 47).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 48). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Burner

Tube

Injector

Holder

Primary

Air Inlet

Holes

Figure 47 - Injector Holder On Outlet Burner Tube (Burner will vary by model)

Pilot Air Inlet Hole

Pilot Air

Inlet Hole

Figure 48 - Pilot Inlet Air Hole (Your pilot assembly may vary from pilots shown)

CLEANING LOGS

If you remove logs for cleaning, refer to Install- ing Logs, page 19, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized

or larger).

28

www.desatech.com

115254-01A

Image 28
Contents VL32HN, LHN VL36EN, LENVL32HP, LHP VL36EP, LEPTable of Contents Safety Information Product Features Blower AccessoryLocal Codes OperationProduct Specifications Locating FireboxPlanning Models42 Models Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingInstallation Installation ClearancesVentilation Air From Outdoors Minimum Wall and Ceiling Clearances see ,Example BUILT-IN Firebox InstallationMinimum 16 inches from Side Wall Rough Opening for Installing Wall Nails or Wood Screws Nailing FlangesInstalling Firebox Using Optional Accessory Mantels Installing Cabinet MantelLower Louver Panel Installing Optional Blower AccessoriesDuplex Electrical Outlet Wiring Diagram Decal 12 Front of Blower Place control knob, provided, onto control shaft see FigureHARD-WIRING Firebox Installing Fireplace Hood and ScreenDuplex Box Handy Box Strain Relief Top View of Rod LayoutInstallation Items Needed Connecting to GAS SupplyVent Pointing Down Propane/LP Checking GAS ConnectionsNatural Test Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaSupply Tank Correct all leaks at onceInstalling Logs Vintage Oak Two-Piece Log SetLog #2 Log #1 Front Post Chassis PostEmber Bed Base Assembly MetalPost Metal PostOperating Fireplace Place top left log on middle log as shown in FigureTop Left Log Top Right Log Middle Left Front Log Right Front LogLighting Instructions Press in control knob and turn counterControl Knob Ignitor ButtonManual Lighting Procedure REMOTE-READY Models For Your Safety Read Before LightingVariable Control Operation To Turn OFF GAS To ApplianceBe hot if heater has been running Follow instructions included with the remote control Control Knob Flame Adjustment On PositionOptional Remote Control Optional HAND-HELD Remote OperationON/OFF Series Model Ghrcb Thermostat Series Model GhrctbPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Cleaning Logs Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyClean ODS/pilot see Low gas pressure AssemblyLeased Long enoughWhen burners are lit Position when burners are Observe minimum installaBurner backfiring during com Bustion DamagedGas leak. See Warning Specifications Wiring DiagramMaximum Minimum Shipping Weight 104 lbs 184 lbs REMOTE-READY Models onlyService Hints Technical ServiceReplacement Parts Parts Under WarrantyAccessories Illustrated Parts Breakdown Parts List Parts Available not Shown46 39 Parts List 23/24 Not Shown Illustrated Parts Breakdown and Parts List 110314-05 Crossover LogKEY LOG Part Numbers VL36 Models VL42 Models Description QTY Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Fireplace