OPERATING FIREPLACE

Continued

LIGHTING

INSTRUCTIONS

WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across openings of fireplace.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before run- ning heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be pres- ent. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to op- erate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the High heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information in column 2, page 21.

2.Make sure equipment shutoff valve is fully open.

3.Press in and turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information in column 1. If you donʼt smell gas, go to the next step.

5.Press in control knob and turn counter-

clockwise to the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 35).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not light, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 23.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7.

8.Push in and turn control knob counter-

clockwise to the HI position. Both burners should light. Set control knob to desired setting.

 

Control Knob

 

Ignitor

LO

PILOT

Button

 

 

 

 

OFF

 

 

HI

Figure 35 - Control Knob and Ignitor

 

Button Location

 

Thermocouple

Ignitor

Ignitor Electrode

Electrode

 

 

Pilot Burner

 

Pilot Burner

Thermocouple

 

Figure 36- Pilots

22

www.desatech.com

115254-01A

Image 22
Contents VL32HP, LHP VL32HN, LHNVL36EN, LEN VL36EP, LEPTable of Contents Safety Information Local Codes Product FeaturesBlower Accessory OperationPlanning Product SpecificationsLocating Firebox Models42 Models Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors InstallationInstallation Clearances Minimum Wall and Ceiling Clearances see ,Example BUILT-IN Firebox InstallationMinimum 16 inches from Side Wall Rough Opening for Installing Wall Nails or Wood Screws Nailing FlangesInstalling Firebox Using Optional Accessory Mantels Installing Cabinet MantelLower Louver Panel Installing Optional Blower AccessoriesDuplex Electrical Outlet Wiring Diagram Decal 12 Front of Blower Place control knob, provided, onto control shaft see FigureDuplex Box Handy Box Strain Relief HARD-WIRING FireboxInstalling Fireplace Hood and Screen Top View of Rod LayoutInstallation Items Needed Connecting to GAS SupplyVent Pointing Down Propane/LP Checking GAS ConnectionsNatural Supply Tank Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Correct all leaks at onceLog #2 Log #1 Front Post Installing LogsVintage Oak Two-Piece Log Set Chassis PostPost Ember Bed Base AssemblyMetal Metal PostTop Left Log Top Right Log Middle Operating FireplacePlace top left log on middle log as shown in Figure Left Front Log Right Front LogControl Knob Ignitor Lighting InstructionsPress in control knob and turn counter ButtonVariable Control Operation Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting To Turn OFF GAS To ApplianceBe hot if heater has been running Optional Remote Control Follow instructions included with the remote controlControl Knob Flame Adjustment On Position Optional HAND-HELD Remote OperationON/OFF Series Model Ghrcb Thermostat Series Model GhrctbPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Cleaning Logs Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyLeased Clean ODS/pilot seeLow gas pressure Assembly Long enoughBurner backfiring during com When burners are lit Position when burners areObserve minimum installa Bustion DamagedGas leak. See Warning Maximum Minimum Shipping Weight 104 lbs 184 lbs SpecificationsWiring Diagram REMOTE-READY Models onlyReplacement Parts Service HintsTechnical Service Parts Under WarrantyAccessories Illustrated Parts Breakdown Parts List Parts Available not Shown46 39 Parts List 23/24 Not Shown Illustrated Parts Breakdown and Parts List 110314-05 Crossover LogKEY LOG Part Numbers VL36 Models VL42 Models Description QTY Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Fireplace