Vermont Casting SDV30 manual Install the Optional Fan, Remove rear skirt insert

Page 13

Install the Optional Fan

If you are installing the optional convection Fan Kit #2767 (FK26), continue here. If you are not installing a Fan Kit, go to Page 14, Venting System Assembly.

1.The fan kit includes a Blower Assembly and a Rheo- stat Assembly, connected by a cable. (Fig. 12) The Blower Assembly mounts to the bottom rear of the stove, and the Rheostat mounts to the valve bracket to the left of the valve. The assembly includes a ‘snapstat’ which automatically turns the fan On (or Off) above (or below) approximately 109˚. The Rheo- stat also provides a range of fan speed settings from Off (which overrides the snapstat function) to High. Unpack and inspect the Blower assembly. Confirm the fan spins freely.

WARNING

This appliance is equipped with a three-prong (grounded) plug for your protection against shock hazard and should be plugged directly into a prop- erly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

Stardance Direct Vent/Natural Vent Gas Heater

4.The rheostat control switch attaches to the left side of the valve bracket at the front of the stove. (Fig. 15)

Remove retaining nut from shaft of rheostat. (if preinstalled)

Insert the rheostat through the hole in the back of the left side of the valve bracket, aligning the locator pin with the smaller hole in that bracket.

Thread the retaining nut onto the shaft of the rheostat, tightening with a wrench. Do not over- tighten.

Attach the control knob to the rheostat shaft.

Use the wire tie to secure the fan and rheostat wire harnesses together.

Rear Skirt

Sheet Metal

Screws

Not Used on RF Models

Not Used on

Stardance

Blower

Assembly

ST473

Snapstat Bracket

Snapstat/

Extension

Assembly

Rheostat

Assembly

Not Used on RF Models

Connect to PC Board on RF Models Only

 

Rear Skirt

ST313

 

Insert

 

Fig. 13 Remove rear skirt insert.

 

 

 

Star Washer

 

Sheet Metal Screws

 

 

1

2

Snapstat

Phillips

 

 

 

 

1/4” - 20

Pan Head

 

 

Hex Bolt

Bolts

 

 

 

 

 

Star

Washer

Snapstat

3 Bracket

Fig. 12 Fan kit components.

2.Remove the rear skirt insert panel at the bottom of the Rear Skirt (Fig. 13) and fasten the blower assem- bly to the firebox back with the two Phillips pan-head bolts originally installed in the firebox back. (‘1’, Fig. 14)

NOTE: Steps 3 and 4 do not apply when the RF valve is used. After attaching blower assembly to the firebox, run the spliced female leads to the front of the stove and attach to back of RF valve. (Page 28, Fig. 51)

3.Attach the snapstat assembly to the snapstat bracket with two sheet-metal screws. (‘2’, Fig. 15) Attach the snapstat bracket to the stove with a hex-head bolt passing through the bracket and into the stove base. (‘3’, Fig. 14)

NOTE: Shown

 

without shell for

ST314

clarification

Fig. 14 Attach the fan assembly and the snapstat.

Rheostat Retaining

Collar

Rheostat Knob

ST347a

 

Fig. 15 Attach the fan rheostat.

20007065

13

Image 13
Contents What to do if YOU Smell GAS Stardance Direct Vent/Natural Vent Gas HeaterTable of Contents General Information Stardance Direct Vent / Natural Vent Dimensions Clearance Requirements Installation RequirementsMinimum Clearances to Combustible MaterialsWall and Ceiling Clearances Wall Centerline from FloorHearth Requirements Gas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal Termination Direct Vent onlyVent Termination Clearances Vertical Termination Direct Vent onlyDirect Vent Only Location of Vent Termination Vent Termination ClearancesGeneral Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and OptionsSimpson DuraVent Components Minimum Horizontal Vent KitRemove rear skirt insert Install the Optional FanVenting System Assemlby Direct Vent General Information Install the Vent Adapter PipeSimpson Dura-Vent install inner adapter pipe Side Wall Termination AssemblyDetermine the vertical pipe length Vent Termination Below Grade Vertical Through the Roof Vent AssemblyInstall firestops and attic insulation shield Venting System Assembly Natural Vent General InformationInstall the Log Set Install the Vent PipeConnect the Gas Supply Line Aged LogsAir Shutter Adjustment Instructions Air Shutter AdjustmentBurner Information Install ON/OFF Switch Complete the AssemblyThermostat Wire / Gauge Install the Front PlateThis completes assembly of the Stardance stove Thermostat Connection optionalFlame Characteristics Your First Fire Flame & Temperature AdjustmentOperation Pilot and Burner InspectionTo Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeFan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path Auto Path Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Models 3900, 3910 R Models Only Honeywell ValvePilot Orifice Conversion Pilot typeModels 3940, 3950 RF Models Only Injector Orifice Size MatrixAll Models 000-5011Logset and Burner Cleaning and Inspection MaintenanceCleaning the Glass Glass ReplacementStove Disassembly Gasket ReplacementInspect the Vent System Annually Check the Gas Flame RegularlyBLK Wiring DiagramsSDV30 DescriptionStardance Direct Vent/Natural Vent Gas Heater SDV30 Fuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Product Covered by this Warranty Limited Lifetime WarrantyProduit Couvert PAR LA Présente Garantie SI UN Service Sous Garantie EST REQUIS…Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings