Vermont Casting SDV30 manual Vent Termination Clearances, Location of Vent Termination

Page 9

Stardance Direct Vent/Natural Vent Gas Heater

Vent Termination Clearances

Your stove is approved to be vented either through the side wall, or vertical through the roof.

CFM Corporation does not require any opening for inspection of vent pipe.

Only CFM Corporation and Simpson DuraVent vent- ing components specifically approved and labelled for this stove may be used.

Minimum clearances between vent pipes and com- bustible materials is one (1”) inch (25 mm), except where stated otherwise.

Venting terminals shall not be recessed into a wall or siding.

Horizontal venting must be installed on a level plane without an inclining or declining slope.

There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24” from the front of the termination hood.

Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termi- nation area after snow falls, and clear to prevent ac- cidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

Location of Vent Termination

It is imperative the vent termination be located observ- ing the minimum clearances as shown on this page.

20007065

9

Image 9
Contents What to do if YOU Smell GAS Stardance Direct Vent/Natural Vent Gas HeaterTable of Contents General Information Stardance Direct Vent / Natural Vent Dimensions Clearance Requirements Installation RequirementsMinimum Clearances to Combustible MaterialsWall Centerline from Floor Wall and Ceiling ClearancesHearth Requirements Gas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal Termination Direct Vent onlyVertical Termination Direct Vent only Vent Termination ClearancesDirect Vent Only Location of Vent Termination Vent Termination ClearancesGeneral Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and OptionsSimpson DuraVent Components Minimum Horizontal Vent KitRemove rear skirt insert Install the Optional FanVenting System Assemlby Direct Vent General Information Install the Vent Adapter PipeSimpson Dura-Vent install inner adapter pipe Side Wall Termination AssemblyDetermine the vertical pipe length Vent Termination Below Grade Vertical Through the Roof Vent AssemblyInstall firestops and attic insulation shield Venting System Assembly Natural Vent General InformationInstall the Log Set Install the Vent PipeConnect the Gas Supply Line Aged LogsAir Shutter Adjustment Air Shutter Adjustment InstructionsBurner Information Install ON/OFF Switch Complete the AssemblyThermostat Wire / Gauge Install the Front PlateThis completes assembly of the Stardance stove Thermostat Connection optionalFlame Characteristics Your First Fire Flame & Temperature AdjustmentOperation Pilot and Burner InspectionTo Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeFan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path Auto Path Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Models 3900, 3910 R Models Only Honeywell ValvePilot Orifice Conversion Pilot typeModels 3940, 3950 RF Models Only Injector Orifice Size MatrixAll Models 000-5011Logset and Burner Cleaning and Inspection MaintenanceCleaning the Glass Glass ReplacementStove Disassembly Gasket ReplacementInspect the Vent System Annually Check the Gas Flame RegularlyBLK Wiring DiagramsSDV30 DescriptionStardance Direct Vent/Natural Vent Gas Heater SDV30 Fuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Product Covered by this Warranty Limited Lifetime WarrantyProduit Couvert PAR LA Présente Garantie SI UN Service Sous Garantie EST REQUIS…Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings