Vermont Casting SDV30 manual Local Path

Page 28

Stardance Direct Vent/Natural Vent Gas Heater

Comfort Valve System Control Sequence of Operation with Transmitter

Set manual switch to local or remote

five minute wait period

Light pilot burner

Did the LED stop blinking?

Release pilotstat

knob

Review LED

failure analysis

Yes

Turn pilotstat knob from PILOT to ON

Local Path

Cycle switch once

 

 

Choose Manual or

and leave in remote.

 

 

 

 

Remote path. Set

Pressy any key on

 

 

 

 

switch to manual or

transmitter for

 

 

 

 

remote.

recognition operation

 

 

 

 

 

 

On Path

If manual switch is set to LOCAL, did main burner light and fan turn on?

Yes

Turn pilotstat knob to PILOT to turn off main burner.

Turn pilotstat knob to OFF to turn valve completely off.

Move switch from local to remote. Press any key on transmitter. Move switch back to local.

If the manual switch is set to REMOTE, press the mode but- ton to display “ON”. Does transmitter con- trol the main burner and fan?

Yes

Does transmitter change levels of flame height, fan speed?

Set levels of flame height and fan to “0: to shut off main burner and fan.

Turn pilotstat knob to OFF to turn valve completely off.

No

Move switch from manual to remote. Press any key on transmitter.

28

20007065

Image 28
Contents Stardance Direct Vent/Natural Vent Gas Heater What to do if YOU Smell GASTable of Contents General Information Stardance Direct Vent / Natural Vent Dimensions Installation Requirements Clearance RequirementsMinimum Clearances to Combustible MaterialsWall and Ceiling Clearances Wall Centerline from FloorHearth Requirements Gas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal Termination Direct Vent onlyVent Termination Clearances Vertical Termination Direct Vent onlyDirect Vent Only Vent Termination Clearances Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesVenting Requirements and Options Approved Vent System ComponentsSimpson DuraVent Components Minimum Horizontal Vent KitInstall the Optional Fan Remove rear skirt insertInstall the Vent Adapter Pipe Venting System Assemlby Direct Vent General InformationSide Wall Termination Assembly Simpson Dura-Vent install inner adapter pipeDetermine the vertical pipe length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldInstall the Vent Pipe Install the Log SetConnect the Gas Supply Line Aged LogsAir Shutter Adjustment Instructions Air Shutter AdjustmentBurner Information Complete the Assembly Install ON/OFF SwitchInstall the Front Plate Thermostat Wire / GaugeThis completes assembly of the Stardance stove Thermostat Connection optionalFlame & Temperature Adjustment Flame Characteristics Your First FireOperation Pilot and Burner InspectionLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionShut Off Procedure Transmitter Operation Off ModeOn Manual Mode Delay Timer ModeAuto Mode Fan Override During Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path Auto Path Conversion Precautions Conversion ProcedureFuel Conversion Instructions Models 3900, 3910 R Models Only Honeywell ValvePilot type Pilot Orifice ConversionInjector Orifice Size Matrix Models 3940, 3950 RF Models OnlyAll Models 000-5011Maintenance Logset and Burner Cleaning and InspectionCleaning the Glass Glass ReplacementGasket Replacement Stove DisassemblyInspect the Vent System Annually Check the Gas Flame RegularlyWiring Diagrams BLKDescription SDV30Stardance Direct Vent/Natural Vent Gas Heater SDV30 Fuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty Product Covered by this WarrantySI UN Service Sous Garantie EST REQUIS… Produit Couvert PAR LA Présente GarantieEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %