Stardance Direct Vent/Natural Vent Gas Heater
Parallel Installation: Minimum Clearance
and Flue Centerline, Direct Vent and
Natural Vent
| C |
| L |
| C |
D | A |
| |
| C |
| L |
B
|
|
| ST128b |
Stove Clearances: | A: 4” (102 mm) | ||
| B: 4” | (102 mm) | |
Pipe Centerlines: | C: | 15¹⁄₂” (395 mm) | |
| D: | 9” | (229 mm) |
Fig. 3 Parallel installation, minimum back and side clear- ances, and flue centerlines.
Corner Installation:
Minimum Clearance and Flue Centerline,
Direct Vent and Natural Vent
B
A
B
| A |
|
|
|
| ST129b |
|
|
|
|
| ||
|
|
|
|
|
| |
|
|
|
|
|
|
|
Stove Clearance: | A: | 4” (102 mm) | ||||
Pipe Centerline: | B: | 14¹⁄₂” (370 mm) |
Fig. 4 Corner installation, minimum corner clearance and flue centerline.
Wall Centerline from Floor
Direct Vent Only
A
| ST131b |
Effective Minimum | |
Wall Thimble | 56” (1480 mm) (CFM Pipe) |
Centerline | 52” (1378 mm) (Simpson Duravent Pipe) |
Fig. 5 Minimum wall thimble centerline.
Wall and Ceiling Clearances
D
B
C
A
| ST101b |
A: Rear Wall | 4” (102 mm) |
B: Min. Clearance | 45¹⁄₄” (1154 mm)* |
C: Min. Alcove Height | 72” (1830 mm) |
D: Max. Alcove Depth | 48” (1220 mm) |
Sidewall Clearance | 4” (102 mm) |
Fig. 5 Dimensions and clearances to ceiling or alcove.
Hearth Requirements
The Stardance Heater must be installed on rigid floor- ing. When the heater is installed directly on any com- bustible surface other than wood flooring, a metal or wood panel extending the full width and depth of the unit must be used as the hearth. There are no other hearth requirements.
6 | 20007065 |