Vermont Casting SDV30 Instructions for RF Comfort Control Valve, Operation, Shut Off Procedure

Page 26

Stardance Direct Vent/Natural Vent Gas Heater

Instructions for RF Comfort Control Valve

The Comfort Control valve allows remote control of tem- perature, fan and flame appearance.

NOTE: The antenna should hang in free air away form grounded metal.

Operation

1.

If the manual switch is in remote position, switch it to

 

LOCAL. (Fig. 49)

2.

Turn the pilotstat knob counterclockwise from OFF to

 

the PILOT position, push the knob down, and hold in

 

position. The pilot valve opens and allows gas to flow

 

to the pilot burner.

3.

Push plunger on the piezo until the pilot burner is lit.

 

When the pilot burner is lit, the LED on the control

 

will come on after approximately 40 seconds and

Shut Off Procedure

If the manual switch is in the REMOTE position, the transmitter can shut off the main burner and fan. How- ever, the control is still on and a command from the transmitter can turn on the main burner or fan.

To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan.

Transmitter Operation

Off Mode

In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off.

will provide 1 short blink continuously in the normal

mode. When the light turns off which will be approxi-

mately 10 seconds after it has been continuously

red, the receiver/valve is fully powered.

Motor Top Cap

Piezo Ignitor

 

 

 

 

 

 

 

 

 

 

PILOT

OFF

 

ON•

 

LOCAL

REMOTE

LED

 

Mode

Auto

On

Off

Countdown

Timer

Fan

FP1039

Display

Room Temperature

Set Temperature

Flame Height Level

Fan Speed Level

Countdown Timer

Low Battery

Flame

Up

Increase Flame Height,

Fan Speed Timer, or

Set Point

Down

Decrease Flame, Fan

Speed Timer or Set

Point

 

 

LED

Local/Remote

Pilotstat

Plug

Switch

Knob

 

Antenna FP1037

Fig. 49 Comfort control valve.

4.Release the knob. The shaft will move upward. The pilot burner should now stay burning. If the pilot burner goes out, repeat step 2.

5.Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately.

6.ON the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to RE- MOTE. Press the fan or flame button on the transmit- ter within 30 seconds. The LED will blink indicating the transmitter will now work with the receiver/valve. If the switch continues in the REMOTE position, the transmitter will now control the main valve, flame modulation level and fan control.

7.If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting and the fan will be at the highest fixed speed. The trans- mitter will control the fan only.

Fig. 50 Transmitter diagram.

On (Manual) Mode

In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons.

When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit.

Delay Timer Mode

The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes.

26

20007065

Image 26
Contents Stardance Direct Vent/Natural Vent Gas Heater What to do if YOU Smell GASTable of Contents General Information Stardance Direct Vent / Natural Vent Dimensions Minimum Clearances to Combustible Installation RequirementsClearance Requirements MaterialsHearth Requirements Wall Centerline from FloorWall and Ceiling Clearances High Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal Termination Direct Vent onlyDirect Vent Only Vertical Termination Direct Vent onlyVent Termination Clearances Vent Termination Clearances Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesSimpson DuraVent Components Venting Requirements and OptionsApproved Vent System Components Minimum Horizontal Vent KitInstall the Optional Fan Remove rear skirt insertInstall the Vent Adapter Pipe Venting System Assemlby Direct Vent General InformationSide Wall Termination Assembly Simpson Dura-Vent install inner adapter pipeDetermine the vertical pipe length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldConnect the Gas Supply Line Install the Vent PipeInstall the Log Set Aged LogsBurner Information Air Shutter AdjustmentAir Shutter Adjustment Instructions Complete the Assembly Install ON/OFF SwitchThis completes assembly of the Stardance stove Install the Front PlateThermostat Wire / Gauge Thermostat Connection optionalOperation Flame & Temperature AdjustmentFlame Characteristics Your First Fire Pilot and Burner InspectionLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path Auto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Models 3900, 3910 R Models Only Honeywell ValvePilot type Pilot Orifice ConversionAll Models Injector Orifice Size MatrixModels 3940, 3950 RF Models Only 000-5011Cleaning the Glass MaintenanceLogset and Burner Cleaning and Inspection Glass ReplacementInspect the Vent System Annually Gasket ReplacementStove Disassembly Check the Gas Flame RegularlyWiring Diagrams BLKDescription SDV30Stardance Direct Vent/Natural Vent Gas Heater SDV30 Fuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty Product Covered by this WarrantySI UN Service Sous Garantie EST REQUIS… Produit Couvert PAR LA Présente GarantieEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %