Vermont Casting SDV30 manual Complete the Assembly, Install ON/OFF Switch

Page 21

8.The air shutter is located on the bottom of the burner to the left. Unfasten the two nuts holding the shutter in place. The shutter may be adjusted between the factory adjusted 1/2” to fully open. Reassemble the shutter to allow the rear injector air inlet to close from the minimum 1/2” opening to fully open. (Fig. 39) You may have to try more than once to find the correct air shutter opening for best results depending on your altitude.

Refer to

Air Shutter

(Original Position)

Table 1

Burner

 

ST352

Fig. 38 Air shutter in original from-the-factory position.

Front Injector

Air Shutter

Air Inlet

(May be adjusted up to fully open)

 

Burner

Rear Injector Air Inlet

ST351

Fig. 39 Air shutter adjusted.

9.Refasten the two nuts and assemble the burner into the unit by sliding the burner in at an angle with the left side lower than the right side. Slide the left side onto the injectors. Lower the right hand side down into place. Make sure the burner is as far left as pos- sible and the injector shoulders are inside the burner. NOTE: It is very critical to keep the left burner leg, which holds the injectors, at a 90° angle to the base. (Fig. 40) This keeps the orifices aligned with tubes on the inside of the burner. Failure to do so could affect the flame appearance and performance of the unit.

10.Refasten the right and left log bracket assembly.

11.Refasten the rear log bracket. 12.Replace logs.

13.Replace glass and stove front.

Follow lighting instructions on Page 25. Check flame color appearance. NOTE: Allow stove to burn for at least 1/2 hour to establish full flame color.

Should color need further adjustment, repeat steps 1 - 12 for air shutter adjustment.

Stardance Direct Vent/Natural Vent Gas Heater

Left Burner Leg

Injector Shoulder

90°

ST353

Fig. 40 Be sure to maintain 90° angle at left burner leg.

Complete the Assembly

Open the swiveling latches (cams) on the top left and right corners of the glass frame.

Position the glass and frame against the firebox by placing the bottom edge on the brackets on the bot- tom face of the firebox.

Swing the assembly against the firebox, and close the latches firmly against the pins protruding from the firebox top.

Install ON/OFF Switch

The switch assembly parts are found in the parts bag.

1.Attach switch assembly to left rear side of stove shroud (when facing shroud) using two screws and existing holes in shroud. (Fig. 41)

2.Run wires down back of stove, under bottom of rear shroud to valve.

3.Attach wires to valve terminals. (Fig. 42)

Switch

Existing Holes

Assembly

Screws

ST315

 

Fig. 41 Attach switch assembly to rear shroud.

PILOT ADJ

 

TPTH

 

TP

 

TH

ST228

Fig. 42 Attach switch wires to valve.

20007065

21

Image 21
Contents What to do if YOU Smell GAS Stardance Direct Vent/Natural Vent Gas HeaterTable of Contents General Information Stardance Direct Vent / Natural Vent Dimensions Clearance Requirements Installation RequirementsMinimum Clearances to Combustible MaterialsWall Centerline from Floor Wall and Ceiling ClearancesHearth Requirements Gas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal Termination Direct Vent onlyVertical Termination Direct Vent only Vent Termination ClearancesDirect Vent Only Location of Vent Termination Vent Termination ClearancesGeneral Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and OptionsSimpson DuraVent Components Minimum Horizontal Vent KitRemove rear skirt insert Install the Optional FanVenting System Assemlby Direct Vent General Information Install the Vent Adapter PipeSimpson Dura-Vent install inner adapter pipe Side Wall Termination AssemblyDetermine the vertical pipe length Vent Termination Below Grade Vertical Through the Roof Vent AssemblyInstall firestops and attic insulation shield Venting System Assembly Natural Vent General InformationInstall the Log Set Install the Vent PipeConnect the Gas Supply Line Aged LogsAir Shutter Adjustment Air Shutter Adjustment InstructionsBurner Information Install ON/OFF Switch Complete the AssemblyThermostat Wire / Gauge Install the Front PlateThis completes assembly of the Stardance stove Thermostat Connection optionalFlame Characteristics Your First Fire Flame & Temperature AdjustmentOperation Pilot and Burner InspectionTo Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeFan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path Auto Path Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Models 3900, 3910 R Models Only Honeywell ValvePilot Orifice Conversion Pilot typeModels 3940, 3950 RF Models Only Injector Orifice Size MatrixAll Models 000-5011Logset and Burner Cleaning and Inspection MaintenanceCleaning the Glass Glass ReplacementStove Disassembly Gasket ReplacementInspect the Vent System Annually Check the Gas Flame RegularlyBLK Wiring DiagramsSDV30 DescriptionStardance Direct Vent/Natural Vent Gas Heater SDV30 Fuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Product Covered by this Warranty Limited Lifetime WarrantyProduit Couvert PAR LA Présente Garantie SI UN Service Sous Garantie EST REQUIS…Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings