Vermont Casting SDV30 Injector Orifice Size Matrix, Models 3940, 3950 RF Models Only, All Models

Page 32

Stardance Direct Vent/Natural Vent Gas Heater

Models 3940, 3950 (RF Models) Only

16.Follow procedure for pilot type 2 to replace pilot orifice.

17.Remove and replace plug on lower right hand side of the valve; Red for LP and Blue for NG. (Page 26, Fig. 49)

18.Remove motor top cap. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 61)

19.Insure manifold pressure remains between 3.2”

-3.5” w.c. for NG and 9,5” - 10” w.c. for LP. To adjust the manifold pressure, for NG, using a torque #10 key turn the blue screw clockwise to increase the manifold pressure. Turn the screw counterclockwise to decrease the pressure. Use the red screw to adjust LP.

20.Replace motor top cap.

 

 

Motor Top Cap

Center

 

 

Plunger

 

 

 

 

Valve

Blue - NG

Red - LP

LOCAL

 

FP1037b

 

 

Fig. 61 Depress and turn center plunger.

All Models

21.Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down in to place. Make sure the burner is as far left as possible and the injector shoulders are inside the burner.

NOTE: It is very critical to keep the left burner leg, which holds the injectors, at a 90° angle to the base. (Fig. 62) This keeps the orifices aligned with the tubes inside burner. Failure to do so could affect the flame appearance and performance of the unit.

22.Place conversion label on valve.

23.Reinstall the right and left log bracket assembly.

24.Reinstall the rear log bracket.

25.Replace logs.

26.Replace glass and stove front. Conversion is complete.

Left Burner Leg

Injector Orifice

90°

ST353a

Fig. 62 Remove and replace injector orifices.

Table 2. Injector Orifice Size Matrix

 

Conversion to Natural Gas

 

Input (Btu/h)

Kit #

Front

Part #

Rear

Part #

Minimum

Maximum

000-5021

#54 / .055”

30000514

#44 / .086”

30000334

19,000

28,000

000-5011

 

 

 

 

 

 

 

 

Conversion to LP

 

Input (Btu/h)

Kit #

Front

Part #

Rear

Part #

Minimum

Maximum

000-5022

#69 / .029”

30000513

#54 / .055”

30000514

20,000

28,000

000-5012

 

 

 

 

 

 

32

20007065

Image 32
Contents Stardance Direct Vent/Natural Vent Gas Heater What to do if YOU Smell GASTable of Contents General Information Stardance Direct Vent / Natural Vent Dimensions Installation Requirements Clearance RequirementsMinimum Clearances to Combustible MaterialsHearth Requirements Wall Centerline from FloorWall and Ceiling Clearances Gas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal Termination Direct Vent onlyDirect Vent Only Vertical Termination Direct Vent onlyVent Termination Clearances Vent Termination Clearances Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesVenting Requirements and Options Approved Vent System ComponentsSimpson DuraVent Components Minimum Horizontal Vent KitInstall the Optional Fan Remove rear skirt insertInstall the Vent Adapter Pipe Venting System Assemlby Direct Vent General InformationSide Wall Termination Assembly Simpson Dura-Vent install inner adapter pipeDetermine the vertical pipe length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldInstall the Vent Pipe Install the Log SetConnect the Gas Supply Line Aged LogsBurner Information Air Shutter AdjustmentAir Shutter Adjustment Instructions Complete the Assembly Install ON/OFF SwitchInstall the Front Plate Thermostat Wire / GaugeThis completes assembly of the Stardance stove Thermostat Connection optionalFlame & Temperature Adjustment Flame Characteristics Your First FireOperation Pilot and Burner InspectionLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionShut Off Procedure Transmitter Operation Off ModeOn Manual Mode Delay Timer ModeAuto Mode Fan Override During Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path Auto Path Conversion Precautions Conversion ProcedureFuel Conversion Instructions Models 3900, 3910 R Models Only Honeywell ValvePilot type Pilot Orifice ConversionInjector Orifice Size Matrix Models 3940, 3950 RF Models OnlyAll Models 000-5011Maintenance Logset and Burner Cleaning and InspectionCleaning the Glass Glass ReplacementGasket Replacement Stove DisassemblyInspect the Vent System Annually Check the Gas Flame RegularlyWiring Diagrams BLKDescription SDV30Stardance Direct Vent/Natural Vent Gas Heater SDV30 Fuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty Product Covered by this WarrantySI UN Service Sous Garantie EST REQUIS… Produit Couvert PAR LA Présente GarantieEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %