Vermont Casting SDV30 manual Description

Page 36

Stardance Direct Vent/Natural Vent Gas Heater

1a

CEMENT

4

2

3

56

7

1c

 

 

 

 

1b

 

 

8a,b

 

 

 

PILOT

OFF

 

 

I

L

 

 

 

 

 

ON

 

 

 

 

H O

 

 

 

 

 

 

 

 

 

 

 

 

 

PILOT ADJ

9a,b

 

 

 

 

PILOT

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

ON•

 

 

 

20

 

LOCAL

REMOTE

 

LED

 

 

 

 

25a,b,

 

c,d

27

 

11 12 13

10a14

15

16

10b

21

28

29

32

18

17

19

10c

22

23

30

24

40

 

39

48a,b

 

31

35

34

 

 

 

38

 

 

 

 

36

 

26

41

33

 

42

49

CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.

Stardance Direct Vent/Natural Vent Gas Heater (SDV30)

Models 3900-3916, 3940-3956

Ref.

Description

SDV30

1.

Gas Log Assembly - SDV30

20003458

1a.

Log Rear (V21)

20003459

1b.

Log Right (V22)

20003460

1c.

Log Left (V23)

20003461

36

20007065

Image 36
Contents Stardance Direct Vent/Natural Vent Gas Heater What to do if YOU Smell GASTable of Contents General Information Stardance Direct Vent / Natural Vent Dimensions Installation Requirements Clearance RequirementsMinimum Clearances to Combustible MaterialsWall Centerline from Floor Wall and Ceiling ClearancesHearth Requirements Gas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal Termination Direct Vent onlyVertical Termination Direct Vent only Vent Termination ClearancesDirect Vent Only Vent Termination Clearances Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesVenting Requirements and Options Approved Vent System ComponentsSimpson DuraVent Components Minimum Horizontal Vent KitInstall the Optional Fan Remove rear skirt insertInstall the Vent Adapter Pipe Venting System Assemlby Direct Vent General InformationSide Wall Termination Assembly Simpson Dura-Vent install inner adapter pipeDetermine the vertical pipe length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldInstall the Vent Pipe Install the Log SetConnect the Gas Supply Line Aged LogsAir Shutter Adjustment Air Shutter Adjustment InstructionsBurner Information Complete the Assembly Install ON/OFF SwitchInstall the Front Plate Thermostat Wire / GaugeThis completes assembly of the Stardance stove Thermostat Connection optionalFlame & Temperature Adjustment Flame Characteristics Your First FireOperation Pilot and Burner InspectionLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionShut Off Procedure Transmitter Operation Off ModeOn Manual Mode Delay Timer ModeAuto Mode Fan Override During Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path Auto Path Conversion Precautions Conversion ProcedureFuel Conversion Instructions Models 3900, 3910 R Models Only Honeywell ValvePilot type Pilot Orifice ConversionInjector Orifice Size Matrix Models 3940, 3950 RF Models OnlyAll Models 000-5011Maintenance Logset and Burner Cleaning and InspectionCleaning the Glass Glass ReplacementGasket Replacement Stove DisassemblyInspect the Vent System Annually Check the Gas Flame RegularlyWiring Diagrams BLKDescription SDV30Stardance Direct Vent/Natural Vent Gas Heater SDV30 Fuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty Product Covered by this WarrantySI UN Service Sous Garantie EST REQUIS… Produit Couvert PAR LA Présente GarantieEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %