Vermont Casting 3390, 3399, 3369, 3354, 3232 Assembly Procedures, Tools Required, Parts Bag Contents

Page 13

Radiance Direct Vent /Natural Vent Gas Heater

Assembly Procedures

WARNING

Failure to position the parts in accor- dance with these diagrams or failure to

use only parts specifically approved for use with this heater may result in property dam- age or personal injury.

This heater and components are heavy. Have help available for assembly.

Tools Required

Phillips screwdriver (stub)

power drill

utility knife

reciprocating saw

metal drill bit: size 28 (.140”/3.5mm)

Parts Bag Contents:

Control door handle/screw

(3) Vent Screws

(2) Switch bracket screws

Ceramic handle w/insert lifter (handle for operable door)

On-Off switch, housing, and wiring harness

(3)Phillips round-head bolts, 1/4”- 20 x 1/2”

(2) Bag of Lava Rocks

(1) Tube of Vent Gasket Cement

(1) Vent Restrictor Plate, 2¹⁄₄" inside diameter

Owner Registration Card

(4) CS, Hex Hd 3/8-16 x 1 Gr 2-Z

(4) Washer, Fl 3/8-Z

Unpack and Assemble Legs

The Radiance is shipped upright. Cut the shipping straps and set stove upright.

1.Slide stove to the rear of the pallet just far enough to access rear leg holes. Make sure the stove does not tip over backwards. (Fig. 12)

2.Attach the rear legs using 3/8” hex head bolts and flat washer supplied. Tighten with a 9/16” wrench or socket.

3.Carefully tip the stove onto its rear legs. Adjust the pallet to allow access to one of the front leg holes. Be sure to leave the pallet under the stove to prevent the stove from falling fully forward. (Fig. 13) CAUTION: To prevent valve tubing from being crushed or damaged, make sure to rest valve on wooden pallet.

ST720

Fig. 12 Slide stove back just far enough to access rear leg holes.

Washer

Hex Head Bolt

Fig. 13 Carefully tip stove onto back legs. Leave pallet under stove to keep stove from falling fully forward.

4.Have your assistant attach one leg using the hard- ware described.

5.Move the pallet to allow access to the other front leg hole. Attach remaining leg.

6.Remove pallet and allow stove to gently rest on all four legs.

7.Adjust leg levelers to compensate for irregularities in the hearth.

NOTE: Verify the two relief doors (located on top of the firebox) are properly seated on the gasket. The doors should sit flush on the gasket, and should lift easily from the seal around the opening.

20004188

13

Image 13
Contents Radiance Direct Vent/Natural Vent Gas Heater Table Of Contents Installation & Operating Instructions Radiance dimensions Radiance Direct Vent/Natural Vent Stove DimensionsLocating The Stove Installation RequirementsClearance Requirements Wall and Ceiling Clearances Wall Centerline from FloorHearth Requirements Gas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal Termination Direct Vent onlyVertical Termination Direct Vent only Restictor Plate is used on Direct Vent installations onlyVent Termination Clearances Location of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2Plate supplied with the stove is not used Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and Options Direct Vent onlyParts Bag Contents Assembly ProceduresTools Required Unpack and Assemble LegsRemove rear shroud Install the Optional FanInstall the Vent Adapter Pipe Venting System Assembly Direct Vent General InformationFor Canadian installations The venting system must Attach the Inner Vent Assembly to the stoveInstall the Outer Adapter Pipe. Orient the verti Side Wall Termination AssemblyDiscard the inner starter pipe shipped with the log Measure the horizontal length Vent Termination Below Grade Vertical Through the Roof Vent AssemblyInstall firestops and attic insulation shield Venting System Assembly Natural Vent General InformationInstall Log Set Install the Vent PipeConnect the Gas Supply Line Install the left and right rear logs and the right logInstall the Mesh and Grille Install ON/OFF SwitchBurner Information Thermostat Connection optionalFlame Characteristics Flame & Temperature AdjustmentOperation Your First FireTo Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeFan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path On Path Auto Path Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Burner Orifice ConversionPilot Orifice Conversion SIT 820 ValvePilot Type 1 SIT Pilot Pilot type 2 Honeywell PilotAll Models Models 3352, 3354, 3390 thru 3399 RF Models OnlyInjector Orifice Size Matrix Air Shutter AdjustmentConversion to Natural Gas Input BTU/h Conversion to LP Input BTU/hMaintenance Inspect the Vent System Annually Gasket ReplacementCheck the Gas Flame Regularly BLK Wiring DiagramsDescription Radiance Direct Vent/Natural Vent Gas Heater RdvodRadiance Direct Vent/Natural Vent Gas Heater Rdvod Shell Enamel Parts Radiance Direct Vent / Natural Vent Fuel Conversion KitsOptional Accessories Radiance Direct Vent /Natural Vent Gas Heater 4242 Limited Lifetime Warranty Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings