Radiance Direct Vent/Natural Vent Gas Heater
Fuel Conversion Instructions
WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruc- tions is not followed exactly, a fire, explosion
or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is respon- sible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before pro- ceeding with the conversion.
| OFF |
I | N |
H O | O |
| TPILOJAD |
| Main |
| Gas Line |
Gas Supply Inlet | |
| ST226 |
Fig. 52 Attach the gas line to the left side of the valve. |
Conversion Precautions
Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.
Conversion Procedure
1.Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 32, Fig. 62)
2.Undo the right and left latches at the top of the glass frame. (Page 32, Fig. 63)
3.Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a coun- ter protected by a towel.
4.Remove the logset from the firebox.
5.Remove the rear log bracket by loosening the screw and lifting the bracket up and away. (Fig. 53)
6.Remove the right and left log bracket assembly by unfastening the two screws which hold the burner in place. (Fig. 53)
Remove Screws | Rear Log Bracket | |
| ||
|
| Pilot |
| Left & Right Log | ST350 |
| Bracket Assembly |
Fig. 53 Remove rear log bracket and left and right log bracket assembly.
Burner Orifice Conversion
1.Hold the burner at the right hand side and lift to clear the right burner leg. Then pull to the right to clear the injectors on the left hand side.
2.Remove injector orifices from left burner leg using 1/2” wrench. (Fig. 61)
3.Install conversion orifices. (Refer to Table 1)
4.Air shutter adjustment. The unit is shipped from the factory with the air shutter open 1”. For LP units only, the air shutter could be closed further. Refer to Table 2 for minimum air shutter opening. The air shutter is located on the bottom of the burner to the left. Unfasten the two nuts holding the shutter in place. Adjust the air shutter as needed according to Table 2. (Fig. 54)
Refer to Table 2 | Burner |
| ST667 |
Fig. 54 Adjust air shutter according to Table 2. |
Models 3350, 3351, 3360 thru 3369 (R Models) Only Honeywell Valve
1.Remove cap from
2.Remove the screw from center of
3030 | 20004188 |