Radiance Direct Vent/Natural Vent Gas Heater
Instructions for RF Comfort Control Valve
The Comfort Control valve allows remote control of temperature, fan and flame appearance.
NOTE: The antenna should hang in free air away from grounded metal.
Operation
1.If the manual switch is in remote position, switch it to LOCAL. (Fig. 49)
2.Turn the pilotstat knob counterclockwise from OFF to the PILOT position, push the knob down, and hold in position. The pilot valve opens and allows gas to flow to the pilot burner.
3.Push plunger on the piezo until the pilot burner is lit. When the pilot burner is lit, the LED on the control will come on after approximately 40 seconds and will provide 1 short blink continuously in the normal mode. When the light turns off which will be approxi- mately 10 seconds after it has been continuously red, the receiver/valve is fully powered.
7.If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting and the fan will be at the highest fixed speed. The transmitter will control the fan only.
Shut Off Procedure
If the manual switch is in the REMOTE position, the transmitter can shut off the main burner and fan. How- ever, the control is still on and a command from the transmitter can turn on the main burner or fan.
To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan.
Transmitter Operation
Off Mode
In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off.
Motor Top Cap | Piezo Ignitor | |||
|
| |||
|
| PILOT | OFF | |
|
|
| • | |
| REMOTE | ON• |
| |
LOCAL |
| LED | ||
|
| LED | ||
Local/Remote | Pilotstat | Plug | ||
Switch | Knob | |||
|
|
Antenna
FP1037
Mode
Auto
On
Off
Countdown
Timer
Fan
FP1039
Display
Room Temperature
Set Temperature
Flame Height Level
Fan Speed Level
Countdown Timer
Low Battery
Flame
Up
Increases Flame
Height, Fan Speed Timer, or Set Point
Down Decrease Flame, Fan Speed Timer or Set Point
Fig. 49 Comfort control valve.
Fig. 50 Transmitter diagram.
4.Release the knob. The shaft will move upward. The pilot burner should now stay burning. If the pilot burner goes out, repeat step 2.
5.Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately.
6.ON the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to REMOTE. Press the fan or flame button on the transmitter within 30 seconds. The LED will blink indicating the transmitter will now work with the re- ceiver/valve. If the switch continues in the REMOTE position, the transmitter will now control the main valve, flame modulation level and fan control.
On (Manual) Mode
In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons.
When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit.
Delay Timer Mode
The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes.