Vermont Casting 3350, 3399, 3369, 3354, 3232, 3225 Radiance Direct Vent/Natural Vent Gas Heater Rdvod

Page 38

Radiance Direct Vent/Natural Vent Gas Heater

Radiance Direct Vent/Natural Vent Gas Heater (RDVOD)

Models: 3225 thru 3232, 3350 thru 3354, 3360 thru 3369, 3390 thru 3399 (continued)

Ref.

Description

RDVOD

7.

Gasket, Glass Med. Knit - RDV40

1203702

8.

Glass, GFP Firebox

1601290

9.

Ceramic Handle w/Insert LFTR

0004345

10a.

Valve RN Honeywell VS8420E 2038 (Serial #’s up to 4939)*

10001782

10b.

Valve RP Honeywell VS8420E 2020 (Serial #’s up to 4939)**

10001759

11a.

Valve Gas Honeywell Convertible RFN RV8310E

20003719

11b.

Valve Gas Honeywell Convertible RFP RV8310E

20003720

12a.

Pilot Assembly 3Way N/DV RN 0.199.706

10002264

 

Pilot Assembly 3Way N/DV RP 0.199.703

10002265

12b.

PIlot PSE - NA175

20001115

 

Pilot PSE - LP175

20001116

12c.

Pilot Assembly 3Way DV/RFN CS3003A2009

20002266

 

Pilot Assembly 3Way DV/RFP CS3003A2017

20002268

13.

Thermocouple 24”

53373

 

 

7531137

14.

Electrode Ignitor w/ Cable SIT24

10001297

15.

Pilot Top Convertible

10002266

16.

Thermopile 18” RS

51827

 

 

7533113

17.

Nut Electrode SIT #0.974.144

57886

18.

Tubing Pilot w/ Fitting 1/8 x 24”

10001296

19.

Thermopile PSE for RF Pilots

20002400

20a.

Pilot Orifice #62 - NG Top Convertible

10002268

20b.

Pilot Orifice #35 - LP Top Convertible

10002269

21a.

PIlot Orifice PSE RFN

20000908

21b.

PIlot Orifice PSE RFP

20000907

22.

Antennae, Honeywell 395783-1

20003561

23.

Front II, RDVOD

Refer to Enamel Parts Chart Page 38

24.

Door Left - RDVOD

Refer to Enamel Parts Chart Page 38

25.

Door Right - RDVOD

Refer to Enamel Parts Chart Page 38

26.

Control Door, RDVOD

Refer to Enamel Parts Chart Page 38

27.

Burner Housing Assembly

20003526

28.

Log Rear Bracket

20003577

29a.

Orifice Hood (.043) - Front - LP

20004587

29b.

Orifice Hood (.067”) - Front - NG

30000449

29c.

Orifice Hood (.055”) - Rear - LP

20000130

29d.

Orifice Hood (.098” ) - Rear - NG

20004263

30.

Gasket Base Pan

20004287

31.

Gasket Inner Base Pan

20004286

32.

Bracket, Right Log

20005259

33.

Bracket, Left Log

20005258

34.

Grate Decorative Burner

20003536

35.

Wire w/Straight Term 2 End 50”

10002582

36.

Transmitter Honeywell RF

20002047

37.

Sensor 2450 CMG-8184-0032

10002013

38.

Damper Steel Handle/Screw

30002720

39.

Latch, Front Door - RDV

30001249

41.

Glass Frame Assembly - RDV40

5003075

44.

Washer, Flat 1/4 - Blk. 266 x .629.064

1202473

45.

CS, Hex Hd 1/4-20 x 5/8” - Blk

1201372

46.

Left End

Refer to Enamel Parts Chart Page 38

3838

20004188

Image 38
Contents Radiance Direct Vent/Natural Vent Gas Heater Table Of Contents Installation & Operating Instructions Radiance Direct Vent/Natural Vent Stove Dimensions Radiance dimensionsClearance Requirements Installation RequirementsLocating The Stove Hearth Requirements Wall Centerline from FloorWall and Ceiling Clearances High Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal Termination Direct Vent onlyVent Termination Clearances Restictor Plate is used on Direct Vent installations onlyVertical Termination Direct Vent only Location of Vent Termination Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Plate supplied with the stove is not usedVenting Requirements and Options Direct Vent only Approved Vent System ComponentsTools Required Assembly ProceduresParts Bag Contents Unpack and Assemble LegsInstall the Optional Fan Remove rear shroudFor Canadian installations The venting system must Venting System Assembly Direct Vent General InformationInstall the Vent Adapter Pipe Attach the Inner Vent Assembly to the stoveDiscard the inner starter pipe shipped with the log Side Wall Termination AssemblyInstall the Outer Adapter Pipe. Orient the verti Measure the horizontal length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldInstall the Vent Pipe Install Log SetInstall the left and right rear logs and the right log Connect the Gas Supply LineBurner Information Install ON/OFF SwitchInstall the Mesh and Grille Thermostat Connection optionalOperation Flame & Temperature AdjustmentFlame Characteristics Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path On Path Auto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Burner Orifice ConversionPilot Type 1 SIT Pilot SIT 820 ValvePilot Orifice Conversion Pilot type 2 Honeywell PilotModels 3352, 3354, 3390 thru 3399 RF Models Only All ModelsConversion to Natural Gas Input BTU/h Air Shutter AdjustmentInjector Orifice Size Matrix Conversion to LP Input BTU/hMaintenance Check the Gas Flame Regularly Gasket ReplacementInspect the Vent System Annually Wiring Diagrams BLKRadiance Direct Vent/Natural Vent Gas Heater Rdvod DescriptionRadiance Direct Vent/Natural Vent Gas Heater Rdvod Fuel Conversion Kits Shell Enamel Parts Radiance Direct Vent / Natural VentOptional Accessories Radiance Direct Vent /Natural Vent Gas Heater 4242 Limited Lifetime Warranty Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %