Vermont Casting 3360, 3399, 3369 SIT 820 Valve, Pilot Orifice Conversion, Pilot Type 1 SIT Pilot

Page 31

Cap

H

Lift Open

HI

 

I

 

LO

 

LO

Hi-Lo

 

 

Knob

Center Screw

CO100

Fig. 55 Remove center screw from Hi-Lo knob.

3.Insert blue painted screw when converting to natural gas and red painted screw when converting to LP.

4.Tighten screw (do not over tighten), replace cap.

SIT 820 Valve

1.Using TORX T20 bit, remove and discard the three

(3) pressure regulator mounting screws (A), pressure regulator tower (B) and the spring and diaphragm assembly (C). (Fig. 56)

A

B

C

 

OFF

 

P

 

 

I

O

TO

L

 

FC107

Fig. 56 Remove mounting screws, pressure regulator tower and spring and diaphragm assembly.

2.Insure the rubber gasket (D) is properly positioned and install the new HI/LO pressure regulator assem- bly to the valve using the new screws (E) supplied with the kit. Tighten the screws securely. (Ref. torque = 25 in/lb) (Fig. 57)

3.Install the enclosed conversion label (F) to the valve body where it can easily be seen. (Fig. 57)

Pilot Orifice Conversion

1.Locate pilot. (Fig. 53)

2.Replace pilot orifice.

Pilot Type 1 (SIT Pilot)

Remove pilot hood by lifting up. (Fig. 58) Do not remove the snap ring to remove the pilot hood. NOTE: It is not necessary to remove the pilot tube for conversion.

Remove pilot orifice with allen wrench. (Fig. 59)

Radiance Direct Vent /Natural Vent Gas Heater

E

OFF

P

I

O TOL

D

 

F

 

FC108

Fig. 57

Replace regulator.

 

Pilot Hood

Pilot

Bracket

 

CO105a

Fig. 58 Remove pilot hood.

Index Tab

Allen Wrench

 

Snap Ring

 

CO106a

 

Fig. 57 Remove pilot orifice.

Install the conversion orifice.

Reinstall pilot hood. Be sure to align hood with index tab.

Pilot type 2 (Honeywell Pilot)

Loosen pilot hood turning counterclockwise using a 7/16” wrench. (Fig. 60) NOTE: You may use pen- etrating oil to prevent pilot hood threads from seizing up.

Remove pilot orifice with needlenose pliers. (Fig.

61)NOTE: Use a wrench to hold pilot tube in place while removing the orifice.

Install the conversion orifice.

Reinstall pilot hood and tighten until mark on pilot

hood aligns with mark on pilot bracket.

20004188

31

Image 31
Contents Radiance Direct Vent/Natural Vent Gas Heater Table Of Contents Installation & Operating Instructions Radiance dimensions Radiance Direct Vent/Natural Vent Stove DimensionsLocating The Stove Installation RequirementsClearance Requirements Wall and Ceiling Clearances Wall Centerline from FloorHearth Requirements Horizontal Termination Direct Vent only Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsVertical Termination Direct Vent only Restictor Plate is used on Direct Vent installations onlyVent Termination Clearances Location of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2Plate supplied with the stove is not used Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and Options Direct Vent onlyUnpack and Assemble Legs Assembly ProceduresParts Bag Contents Tools RequiredRemove rear shroud Install the Optional FanAttach the Inner Vent Assembly to the stove Venting System Assembly Direct Vent General InformationInstall the Vent Adapter Pipe For Canadian installations The venting system mustInstall the Outer Adapter Pipe. Orient the verti Side Wall Termination AssemblyDiscard the inner starter pipe shipped with the log Measure the horizontal length Vent Termination Below Grade Vertical Through the Roof Vent AssemblyInstall firestops and attic insulation shield Venting System Assembly Natural Vent General InformationInstall Log Set Install the Vent PipeConnect the Gas Supply Line Install the left and right rear logs and the right logThermostat Connection optional Install ON/OFF SwitchInstall the Mesh and Grille Burner InformationYour First Fire Flame & Temperature AdjustmentFlame Characteristics OperationTo Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemDelay Timer Mode Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeDisable Thermostat Function Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsLocal Path On Path Auto Path Burner Orifice Conversion Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsPilot type 2 Honeywell Pilot SIT 820 ValvePilot Orifice Conversion Pilot Type 1 SIT PilotAll Models Models 3352, 3354, 3390 thru 3399 RF Models OnlyConversion to LP Input BTU/h Air Shutter AdjustmentInjector Orifice Size Matrix Conversion to Natural Gas Input BTU/hMaintenance Inspect the Vent System Annually Gasket ReplacementCheck the Gas Flame Regularly BLK Wiring DiagramsDescription Radiance Direct Vent/Natural Vent Gas Heater RdvodRadiance Direct Vent/Natural Vent Gas Heater Rdvod Shell Enamel Parts Radiance Direct Vent / Natural Vent Fuel Conversion KitsOptional Accessories Radiance Direct Vent /Natural Vent Gas Heater 4242 Limited Lifetime Warranty Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings