Vermont Casting 3360 Fuel Conversion Kits, Shell Enamel Parts Radiance Direct Vent / Natural Vent

Page 39

Radiance Direct Vent /Natural Vent Gas Heater

Radiance Direct Vent/Natural Vent Gas Heater (RDVOD)

Models: 3225 thru 3232, 3350 thru 3354, 3360 thru 3369, 3390 thru 3399 (continued)

Ref.

Description

 

RDVOD

47.

Right End

 

Refer to Enamel Parts Chart Page 38

48.

Leg

 

Refer to Enamel Parts Chart Page 38

49.

Control Door Handle Assembly

 

30002730

50.

Gasket, HE Door

 

1203687

51.

Top

 

Refer to Enamel Parts Chart Page 38

52.

FK26 Fan Subassembly (RF Only)

 

30000879

53.

Grille, RDV40

 

1301195

54.

Screen, Top RDV40

 

1601970

55a.

Valve Nova SIT820.662 RN (Serial #’s starting with 4940)

20010563

55b.

Valve Nova SIT820.653 RP (Serial #’s starting with 4940)

20010645

56.

Ignitor Piezo w/Nut SIT

 

52464

57.

Bracket Piezo Ignitor (not shown)

 

20010876

*When converting to SIT valve, must order RP275

 

 

**When converting to SIT valve, must order RP269

 

 

Fuel Conversion Kits

 

 

Conversion Kit, NG to LP - RDVOD-RFN

Kit #000-5003

 

Conversion Kit, NG to LP - RDVOD-RN

Kit #000-5010

 

Conversion Kit, LP to NG - RDVOD-RFP

Kit #000-5002

 

Conversion Kit, LP to NG - RDVOD-RP

Kit #000-5009

 

Shell Enamel Parts - Radiance Direct Vent / Natural Vent

Enamel

Model

Top

Left

Right

Front

Left

Right

Control

Leg

Color

 

 

End

End

 

Door

Door

Door

(4)

Classic

3360, 3365

1301194

30001751

30001752

30001376

30001378

30001377

30001413

30001753

 

3390, 3395

 

 

 

 

 

 

 

 

Biscuit

3225, 3229

30003244

30003239

30003238

30003240

30003242

30003241

30003243

30003245

Bordeaux

3361, 3366

2321194

30001771

30001770

30001416

30001418

30001417

30001419

30001772

 

3391, 3396

 

 

 

 

 

 

 

 

Chestnut

3226, 3230

30003253

30003248

30003247

30003249

30003251

30003250

30003252

30003254

Brown

 

 

 

 

 

 

 

 

 

Ebony

3227, 3231

30003262

30003257

30003256

30003258

30003260

30003259

30003261

30003263

Forest

3364, 3369

2311194

30001780

30001779

30001428

30001430

30001429

30001431

30001781

Green

3394, 3399

 

 

 

 

 

 

 

 

Midnight

3363, 3368

2371194

30001777

30001776

30001424

30001426

30001425

30001427

30001778

Blue

3393, 3398

 

 

 

 

 

 

 

 

Sand

3362, 3367

1321194

30001774

30001773

30001420

30001422

30001421

30001423

30001775

 

3392, 3397

 

 

 

 

 

 

 

 

Suede

3350, 3351

30002546

30002512

30002511

30002514

30002516

30002515

30002517

30002518

Brown

3352, 3354

 

 

 

 

 

 

 

 

Vermont

3228, 3232

30003271

30003266

30003265

30003267

30003269

30003268

30003270

30003272

Cl. Green

 

 

 

 

 

 

 

 

 

20004188

39

Image 39
Contents Radiance Direct Vent/Natural Vent Gas Heater Table Of Contents Installation & Operating Instructions Radiance dimensions Radiance Direct Vent/Natural Vent Stove DimensionsInstallation Requirements Locating The StoveClearance Requirements Wall Centerline from Floor Wall and Ceiling ClearancesHearth Requirements Horizontal Termination Direct Vent only Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsRestictor Plate is used on Direct Vent installations only Vertical Termination Direct Vent onlyVent Termination Clearances Location of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2Plate supplied with the stove is not used Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and Options Direct Vent onlyUnpack and Assemble Legs Assembly ProceduresParts Bag Contents Tools RequiredRemove rear shroud Install the Optional FanAttach the Inner Vent Assembly to the stove Venting System Assembly Direct Vent General InformationInstall the Vent Adapter Pipe For Canadian installations The venting system mustSide Wall Termination Assembly Install the Outer Adapter Pipe. Orient the vertiDiscard the inner starter pipe shipped with the log Measure the horizontal length Vent Termination Below Grade Vertical Through the Roof Vent AssemblyInstall firestops and attic insulation shield Venting System Assembly Natural Vent General InformationInstall Log Set Install the Vent PipeConnect the Gas Supply Line Install the left and right rear logs and the right logThermostat Connection optional Install ON/OFF SwitchInstall the Mesh and Grille Burner InformationYour First Fire Flame & Temperature AdjustmentFlame Characteristics OperationTo Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemDelay Timer Mode Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeDisable Thermostat Function Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsLocal Path On Path Auto Path Burner Orifice Conversion Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsPilot type 2 Honeywell Pilot SIT 820 ValvePilot Orifice Conversion Pilot Type 1 SIT PilotAll Models Models 3352, 3354, 3390 thru 3399 RF Models OnlyConversion to LP Input BTU/h Air Shutter AdjustmentInjector Orifice Size Matrix Conversion to Natural Gas Input BTU/hMaintenance Gasket Replacement Inspect the Vent System AnnuallyCheck the Gas Flame Regularly BLK Wiring DiagramsDescription Radiance Direct Vent/Natural Vent Gas Heater RdvodRadiance Direct Vent/Natural Vent Gas Heater Rdvod Shell Enamel Parts Radiance Direct Vent / Natural Vent Fuel Conversion KitsOptional Accessories Radiance Direct Vent /Natural Vent Gas Heater 4242 Limited Lifetime Warranty Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings