Vermont Casting 3232, 3399, 3369, 3354, 3225 Gasket Replacement, Inspect the Vent System Annually

Page 35

ST141

Fig. 65 Release the latches to remove the glass frame.

Gasket Replacement

The Radiance Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer.

Shut off the gas supply and allow the stove to cool. Wear safety goggles and a dust mask.

1.Remove the Front, Glass Frame and Glass Panel. (Figs. 62 & 63) Remove the old gasket. Use a razor blade to separate the glass and gasket from the frame, and to clean the glass of any remaining cement or bits of gasket. Use a cold chisel if neces- sary.

2.Determine the correct length of gasket by laying it out around the edge of the glass. Allow an extra 1

- 2” (25-50mm). Mark the spot to be cut. Use a utility knife.

3.Starting on a long edge, remove about 6” of the pro- tective paper strip and apply the flat adhesive face of the gasket around the outside-facing edge of the panel. Continue around the panel, applying a bout 6” at a time and being careful to not stretch the mate- rial. Do not overlap the gasket ends. (Fig. 66)

4.Apply a thin bead of high temperature silicone rubber sealant along the inside corner of the glass frame, all around the perimeter. Place the flat gasketed side of the glass panel back into the steel frame. Pinch the rounded inside-facing gasket mate- rial to bulk it up.

5.Replace the glass frame and front panel as previ- ously described.

Radiance Direct Vent /Natural Vent Gas Heater

 

ST179

Fig. 66

Wrap the gasket material around the outside edge of

the glass.

Inspect the Vent System Annually

Have the vent system inspected annually by a quali- fied technician. Shut off the main gas supply before inspecting the system. Both the inner exhaust pipe and the outer combustion supply pipe must be checked to

confirm that they are unblocked and in good condition.

Check the Gas Flame Regularly

To ensure that the stove is operating properly, check the flames periodically to confirm that they match Figure 67. The flames will be blue during the first 15-20 minutes of operation, and will gradually turn to yellow after that.

Do not use your stove if the flame pattern differs from that shown here. Contact your Vermont Castings dealer or a qualified technician for help.

Red

 

Glow

 

LG157

Fig. 67

Correct flame pattern.

20004188

35

Image 35
Contents Radiance Direct Vent/Natural Vent Gas Heater Table Of Contents Installation & Operating Instructions Radiance dimensions Radiance Direct Vent/Natural Vent Stove DimensionsClearance Requirements Installation RequirementsLocating The Stove Hearth Requirements Wall Centerline from FloorWall and Ceiling Clearances Horizontal Termination Direct Vent only Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsVent Termination Clearances Restictor Plate is used on Direct Vent installations onlyVertical Termination Direct Vent only Location of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2Plate supplied with the stove is not used Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and Options Direct Vent onlyUnpack and Assemble Legs Assembly ProceduresParts Bag Contents Tools RequiredRemove rear shroud Install the Optional FanAttach the Inner Vent Assembly to the stove Venting System Assembly Direct Vent General InformationInstall the Vent Adapter Pipe For Canadian installations The venting system mustDiscard the inner starter pipe shipped with the log Side Wall Termination AssemblyInstall the Outer Adapter Pipe. Orient the verti Measure the horizontal length Vent Termination Below Grade Vertical Through the Roof Vent AssemblyInstall firestops and attic insulation shield Venting System Assembly Natural Vent General InformationInstall Log Set Install the Vent PipeConnect the Gas Supply Line Install the left and right rear logs and the right logThermostat Connection optional Install ON/OFF SwitchInstall the Mesh and Grille Burner InformationYour First Fire Flame & Temperature AdjustmentFlame Characteristics OperationTo Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemDelay Timer Mode Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeDisable Thermostat Function Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsLocal Path On Path Auto Path Burner Orifice Conversion Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsPilot type 2 Honeywell Pilot SIT 820 ValvePilot Orifice Conversion Pilot Type 1 SIT PilotAll Models Models 3352, 3354, 3390 thru 3399 RF Models OnlyConversion to LP Input BTU/h Air Shutter AdjustmentInjector Orifice Size Matrix Conversion to Natural Gas Input BTU/hMaintenance Check the Gas Flame Regularly Gasket ReplacementInspect the Vent System Annually BLK Wiring DiagramsDescription Radiance Direct Vent/Natural Vent Gas Heater RdvodRadiance Direct Vent/Natural Vent Gas Heater Rdvod Shell Enamel Parts Radiance Direct Vent / Natural Vent Fuel Conversion KitsOptional Accessories Radiance Direct Vent /Natural Vent Gas Heater 4242 Limited Lifetime Warranty Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings