XDV Direct Vent Gas Fireplace
3.Connect the white wire from the wall switch or wall thermostat to the white wire terminal from the elec- tronic module. Connect the black wire from the wall switch or the red wire from the wall thermostat, to the red wire terminal from the electronic module.
Optional Top Vent Application
The 33/36/39XDV fireplaces are shipped as rear vent units. If the layout requires a top vent, convert the unit following the steps below.
1.Remove the 10 screws securing outer collar adapter to fireplace. (Fig. 11)
2.Set outer collar adapter aside.
3.Carefully remove and discard the insulation directly below the 7” hole in the cabinet top. The insulation is perforated around the hole to aid in its removal.
Remove the four (4) screws securing flue cover to top of unit and remove flue cover. (Fig. 12)
4.Remove the four (4) screws securing the flue pipe as- sembly to the appliance. Remove flue pipe. (Fig. 12)
5.Secure flue cover to back of flue outlet. (Fig. 13)
6.Install flue pipe and gasket removed in step 4 to top of unit with four (4) screws. (Fig. 13)
7.Secure outer collar adapter to unit with the round collar on top, secure with 10 screws. (Fig. 14)
NOTE: Be sure not to damage any gasket material.
Remove Insulation 7” |
|
Diameter Notch Out | Remove Screws (4) |
|
Flue Cover
Remove Screws (4) | FP1549 |
|
Fig. 12 Remove flue cover and flue pipe.
Flue Pipe
Install Screws (4)
Back in Place
Flue
Cover
Install Screws (4) | FP1551 | |
Back in Place | ||
|
Fig. 13 Replace flue cover and flue pipe.
Outer Collar
Adapter
Flue Pipe
Remove Screws
(5)
Install Screws (5)
Back in Place
Outer Collar Adapter
Remove |
|
Screws (5) | FP1458 |
Fig. 11 Remove screws from outer collar adapter.
Install Screws (5) |
|
Back in Place | FP1550 |
|
Fig. 14 Completed conversion.
After conversion to top vent configuration, the 4” (102 mm) flue pipe should be con- centric within the 7” (175 mm) outer collar.
10 | 10009383 |