XDV Direct Vent Gas Fireplace
2.Slide the Remote/Local switch to REMOTE and teach the valve a transmitter (refer to Item 6, page 32). The Error Code will clear itself after approxi- mately 1¹⁄₂ minutes and return to normal operation.
LED Count | Service Action |
8 | Replace valve |
7Confirm stepper motor connection exists
5Confirm fan connection exists and works
4Confirm gas type; jumper in place
3 Replace thermopiles
2 Turn fan ON
NOTE: Some keys are not active.
Auto Path
| If the manual switch is |
|
|
|
|
| |||||
| set to REMOTE, press |
|
|
|
|
| |||||
|
|
| Move switch | ||||||||
| the mode button to |
|
| ||||||||
|
|
| from LOCAL to | ||||||||
| display AUTO on the |
|
| ||||||||
|
|
| REMOTE. Press | ||||||||
| transmitter. Does the |
|
| ||||||||
|
|
| any key within 30 | ||||||||
| transmitter display the |
|
| ||||||||
|
|
| seconds. | ||||||||
| room and temperature |
|
| ||||||||
|
|
|
|
|
| ||||||
|
| setting? |
|
|
|
|
| ||||
| Yes |
|
|
|
|
|
|
| |||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||
| If the setting is above |
| No |
| |||||||
| room temperature on |
|
| ||||||||
| the transmitter, does the |
|
|
|
|
| |||||
|
|
|
|
|
| ||||||
| main valve and fan turn |
|
|
|
|
| |||||
|
| on? |
|
|
|
|
| ||||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| Yes |
|
|
|
|
|
| ||||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||
| If the setting is below |
| No |
| |||||||
| room temperature on |
|
| ||||||||
|
|
|
|
|
| ||||||
| the transmitter, does |
|
|
|
|
| |||||
|
|
|
|
|
| ||||||
| the main valve and fan |
|
|
|
|
| |||||
|
| turn |
| off? |
|
|
|
|
| ||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Turn pilotstat knob |
|
|
|
|
| |||||
| to OFF to turn valve |
|
|
|
|
| |||||
|
| completely off |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
36 | 10009383 |