Instructions for RF Comfort Control Valve

XDV Direct Vent Gas Fireplace

Instructions for RF Comfort Control Valve

The Comfort Control Valve allows remote control of temperature, fan and flame appearance.

NOTE: The antenna should hang in free air away from grounded metal.

Operation

1.If the manual switch is in remote position, switch it to LOCAL. (Fig. 70)

2.Turn the pilotstat knob counterclockwise from OFF to the PILOT position, push the knob down, and hold in position. The pilot valve opens and allows gas to flow to the pilot burner.

3.Push plunger on the piezo until the pilot burner is lit. When the pilot burner is lit, the LED on the control will come on after approximately 40 seconds and will be continuously red. When the light turns off which will be approximately 10 seconds after it has been continuously red, the receiver/valve is fully powered.

7.If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting. The transmitter will control the fan only.

Shut Off Procedure

If the manual switch is in the REMOTE position, the transmitter can shut off the main burner and fan. How- ever, the control is still on and a command from the transmitter can turn on the main burner or fan.

To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan.

Transmitter Operation

Off Mode

In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off.

Motor Top

 

Piezo Ignitor

Cap

 

 

 

 

 

 

PILOT

OFF

 

 

 

 

 

ON•

 

LOCAL

REMOTE

 

LED

 

 

LED

Local/

Pilotstat

Plug

Remote Switch

Knob

 

 

Antenna

FP1037

Fig. 70 Comfort control valve.

Mode

Auto

On

Off

Countdown Timer

Fan

FP1039

Display

Room Temperature

Set Temperature

Flame Height Level

Fan Speed Level

Countdown Timer

Low Battery

Flame

Up

Increases Flame

Height, Fan Speed Timer, or Set Point

Down Decrease Flame, Fan Speed Timer or Set Point

4.Release the knob. The shaft will move upward. The pilot burner should now stay burning. If the pilot burner goes out, repeat step 2.

5.Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately.

6.ON the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to REMOTE. Press the fan or flame button on the transmitter within 30 seconds. The LED will blink indicating the transmitter will now work with the re- ceiver/valve. If the switch continues in the REMOTE position, the transmitter will now control the main valve, flame modulation level and fan control.

Fig. 71 Transmitter diagram.

On (Manual) Mode

In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons.

When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit.

34

10009383

Image 34
Contents INSTALLER/CONSUMER SAFETY INFORMATION Installation Instructions and Homeowner’s ManualDirect Vent Models: 33XDV, 36XDV, 39XDV Installation & Operating Instructions Table of ContentsXDV Direct Vent Gas Fireplace MaintenanceXDV Direct Vent Gas Fireplace Installation & Operating InstructionsLocating Your Fireplace 10009383XDV Direct Vent Gas Fireplace XDV Fireplace Dimensions - Installed as Rear VentFraming Dimensions 33XDVXDV Direct Vent Gas Fireplace XDV Fireplace Dimensions - Installed as Top VentFraming Dimensions 33XDVHearth Clearance to CombustiblesMantels Cold climate installation recommendationFinal Finishing Gas Line InstallationFraming and Finishing Gas SpecificationsEB-1Electrical Box Remote ON/OFF SwitchAlternate Switch Location XDV Direct Vent Gas FireplaceXDV Direct Vent Gas Fireplace Electronic Gas Control Valve10009383 XDV Direct Vent Gas Fireplace Optional Top Vent Application10009383 33XDV Restrictor Plate Installation General VentingTop Vent Application Restrictor Plate 36XDV Restrictor Plate InstallationXDV Direct Vent Gas Fireplace Canadian Installations1US Installations2 10009383Canadian Installations General Information Assembling Vent PipesFlex Vent Pipes USA InstallationsRear Wall Venting Applications How to Use the Vent GraphTwist Lock Pipes XDV Direct Vent Gas FireplaceSTEP Rear Wall Installation Twist Lock PipeXDV Direct Vent Gas Fireplace STEPXDV Direct Vent Gas Fireplace Rear Wall Vent Installations Flex Vent PipeVertical Sidewall Applications StepTotal angular variation = XDV Direct Vent Gas Fireplace10009383 STEP Vertical Sidewall Installation Twist Lock PipeXDV Direct Vent Gas Fireplace STEPSTEP Vertical Sidewall Installation Flex Vent PipeXDV Direct Vent Gas Fireplace STEPXDV Direct Vent Gas Fireplace Below Grade InstallationsVertical Through-the-RoofApplication Do not backfill around snorkelXDV Direct Vent Gas Fireplace Vertical Through-the-RoofInstallation10009383 Typical Roof SupportTypical Ceiling XDV Direct Vent Gas Fireplace10009383 ApplicationSupport ApplicationVenting Components XDV Direct Vent Gas FireplaceReplacement Of Ceramic Hearth Panels Window Frame Assembly RemovalGlass Cleaning Operating Instructions33XDV Installation of LogsLog Identification Chart XDV Direct Vent Gas FireplaceXDV Direct Vent Gas Fireplace 36XDV10009383 10009383 XDV Direct Vent Gas FireplaceLog Center Right B153 XDV Direct Vent Gas Fireplace 39XDV10009383 XDV Direct Vent Gas Fireplace 10009383Flame Characteristics Burner Lava Rock PlacementFlame & Temperature Adjustment Large Lava Rock36XDV XDV Direct Vent Gas Fireplace33XDV 39XDVLighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTINGLighting and Operating Instructions To Turn Off Gas To Heaterbefore Lighting the Appliance For Your Safety, Read the Following WarningsLighting & Operating Instructions Lighting InstructionsOperation Shut Off ProcedureInstructions for RF Comfort Control Valve Transmitter Operation Off ModeTroubleshooting Delay Timer ModeDisable Thermostat Function Auto ModeLED Count Service ActionXDV Direct Vent Gas Fireplace Replace valveLocal Path XDV Direct Vent Gas FireplaceOn Path 10009383XDV Direct Vent Gas Fireplace Troubleshooting the Gas Control SystemSYMPTOM POSSIBLE CAUSESNormal Operation Troubleshooting the Gas Control SystemXDV Direct Vent Gas Fireplace Abnormal OperationBurner Orifice Conversion 33/36XDV XDV Direct Vent Gas FireplaceHoneywell Valve NOVA SIT820 ValvePilot Orifice Conversion Burner Orifice Conversion 39XDVXDV Direct Vent Gas Fireplace 10009383Installation Precautions Fuel Conversion InstructionsHoneywell Comfort Control Valve ONLY Conversion ProcedurePilot Orifice Conversion 39XDVXDV Direct Vent Gas Fireplace 10009383Conversion to Natural Gas Table 1 Injector Orifice Size MatrixXDV Direct Vent Gas Fireplace Burner Orificefireplace has been in use. FK24/FK12 Fan Assembly MaintenanceCleaning the Standing Pilot Control System XDV Direct Vent Gas FireplaceXDV Direct Vent Gas Fireplace 33XDV/36XDV/39XDV10009383 Description 33XDV/36XDV/39XDV continuedXDV Direct Vent Gas Fireplace 33XDVDescription 33XDV/36XDV/39XDV continuedXDV Direct Vent Gas Fireplace 33XDVFan Kits Optional Accessories AvailableHard Direct Wire Hook Up Turn off all power before hook upInstallation Instructions Remote ControlsCeramic Refractory Panels XDV Direct Vent Gas FireplaceFiligree Louvre Kit Optional Trim KitsScreen Door Kit Arch/Square Face KitXDV Direct Vent Gas Fireplace 10009383XDV Direct Vent Gas Fireplace 10009383XDV Direct Vent Gas Fireplace 10009383IF WARRANTY SERVICE IS NEEDED… LIMITED LIFETIME WARRANTYPRODUCT COVERED BY THIS WARRANTY 2DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELFModel Efficiency RatingsCFM Corporation EnerGuide Ratings