Vermont Casting 33XDV Remote Controls, Ceramic Refractory Panels, XDV Direct Vent Gas Fireplace

Page 50
Remote Controls

XDV Direct Vent Gas Fireplace

Remote Controls

Optional remote control units are available to control dif- ferent functions of the appliance. (For use on R Models)

 

Section A

Heat

Heat Shield

 

 

Shield

Model

 

Functions Controlled

 

RC1

 

ON/OFF

 

 

RC2

 

ON/OFF and Temperature

 

IMTFK

Wall mounted thermostat control

 

 

 

 

Ceramic Refractory Panels

 

 

 

 

 

Unit

 

Kit Model and Finishings

 

Sandstone

Red

Black

Grey

33XDV

 

GAHC3I0

GAFC3I0

GABC3I0

GAGC3I0

36XDV

 

GAHC3J0

GAFC3J0

GABC3J0

GAGC3J0

39XDV

GAHC3K0

GAFC3K0

GABC3K0 GAGC3K0

Take care when handling the refractory panels as they are fragile until held in place and supported.

Installation Instructions

1.

Remove window frame assembly and logs.

2.

Remove three (3) screws securing heat shield to

 

combustion dome. (Fig. 93)

Fig. 93 Heat shield.

Rear

Ceramic Panel

Burner

Functions Controlled(3)

Screws

Side View

Section A

H103

IMTFK Back of Firebox

3.

Place rear ceramic panel in back of unit. (Fig. 94)

4.

Place side panels.

5.

Re-install heat shield, logs and window frame as-

 

sembly.

Ceramic Refractory Panels Rear Log

Support

H102

Fig. 94 Rear ceramic panel placement.

50

10009383

Image 50
Contents Direct Vent Models: 33XDV, 36XDV, 39XDV Installation Instructions and Homeowner’s ManualINSTALLER/CONSUMER SAFETY INFORMATION Installation & Operating Instructions Table of ContentsXDV Direct Vent Gas Fireplace MaintenanceXDV Direct Vent Gas Fireplace Installation & Operating InstructionsLocating Your Fireplace 10009383XDV Direct Vent Gas Fireplace XDV Fireplace Dimensions - Installed as Rear VentFraming Dimensions 33XDVXDV Direct Vent Gas Fireplace XDV Fireplace Dimensions - Installed as Top VentFraming Dimensions 33XDVHearth Clearance to CombustiblesMantels Cold climate installation recommendationFinal Finishing Gas Line InstallationFraming and Finishing Gas SpecificationsEB-1Electrical Box Remote ON/OFF SwitchAlternate Switch Location XDV Direct Vent Gas Fireplace10009383 Electronic Gas Control ValveXDV Direct Vent Gas Fireplace 10009383 Optional Top Vent ApplicationXDV Direct Vent Gas Fireplace 33XDV Restrictor Plate Installation General VentingTop Vent Application Restrictor Plate 36XDV Restrictor Plate InstallationXDV Direct Vent Gas Fireplace Canadian Installations1US Installations2 10009383Canadian Installations General Information Assembling Vent PipesFlex Vent Pipes USA InstallationsRear Wall Venting Applications How to Use the Vent GraphTwist Lock Pipes XDV Direct Vent Gas FireplaceSTEP Rear Wall Installation Twist Lock PipeXDV Direct Vent Gas Fireplace STEPXDV Direct Vent Gas Fireplace Rear Wall Vent Installations Flex Vent PipeVertical Sidewall Applications Step10009383 XDV Direct Vent Gas FireplaceTotal angular variation = STEP Vertical Sidewall Installation Twist Lock PipeXDV Direct Vent Gas Fireplace STEPSTEP Vertical Sidewall Installation Flex Vent PipeXDV Direct Vent Gas Fireplace STEPXDV Direct Vent Gas Fireplace Below Grade InstallationsVertical Through-the-RoofApplication Do not backfill around snorkel10009383 Vertical Through-the-RoofInstallationXDV Direct Vent Gas Fireplace Typical Roof SupportTypical Ceiling XDV Direct Vent Gas Fireplace10009383 ApplicationSupport ApplicationVenting Components XDV Direct Vent Gas FireplaceReplacement Of Ceramic Hearth Panels Window Frame Assembly RemovalGlass Cleaning Operating Instructions33XDV Installation of LogsLog Identification Chart XDV Direct Vent Gas Fireplace10009383 36XDVXDV Direct Vent Gas Fireplace Log Center Right B153 XDV Direct Vent Gas Fireplace10009383 10009383 39XDVXDV Direct Vent Gas Fireplace XDV Direct Vent Gas Fireplace 10009383Flame Characteristics Burner Lava Rock PlacementFlame & Temperature Adjustment Large Lava Rock36XDV XDV Direct Vent Gas Fireplace33XDV 39XDVLighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTINGLighting and Operating Instructions To Turn Off Gas To Heaterbefore Lighting the Appliance For Your Safety, Read the Following WarningsLighting & Operating Instructions Lighting InstructionsOperation Shut Off ProcedureInstructions for RF Comfort Control Valve Transmitter Operation Off ModeTroubleshooting Delay Timer ModeDisable Thermostat Function Auto ModeLED Count Service ActionXDV Direct Vent Gas Fireplace Replace valveLocal Path XDV Direct Vent Gas FireplaceOn Path 10009383XDV Direct Vent Gas Fireplace Troubleshooting the Gas Control SystemSYMPTOM POSSIBLE CAUSESNormal Operation Troubleshooting the Gas Control SystemXDV Direct Vent Gas Fireplace Abnormal OperationBurner Orifice Conversion 33/36XDV XDV Direct Vent Gas FireplaceHoneywell Valve NOVA SIT820 ValvePilot Orifice Conversion Burner Orifice Conversion 39XDVXDV Direct Vent Gas Fireplace 10009383Installation Precautions Fuel Conversion InstructionsHoneywell Comfort Control Valve ONLY Conversion ProcedurePilot Orifice Conversion 39XDVXDV Direct Vent Gas Fireplace 10009383Conversion to Natural Gas Table 1 Injector Orifice Size MatrixXDV Direct Vent Gas Fireplace Burner Orificefireplace has been in use. FK24/FK12 Fan Assembly MaintenanceCleaning the Standing Pilot Control System XDV Direct Vent Gas Fireplace10009383 33XDV/36XDV/39XDVXDV Direct Vent Gas Fireplace Description 33XDV/36XDV/39XDV continuedXDV Direct Vent Gas Fireplace 33XDVDescription 33XDV/36XDV/39XDV continuedXDV Direct Vent Gas Fireplace 33XDVFan Kits Optional Accessories AvailableHard Direct Wire Hook Up Turn off all power before hook upInstallation Instructions Remote ControlsCeramic Refractory Panels XDV Direct Vent Gas FireplaceFiligree Louvre Kit Optional Trim KitsScreen Door Kit Arch/Square Face KitXDV Direct Vent Gas Fireplace 10009383XDV Direct Vent Gas Fireplace 10009383XDV Direct Vent Gas Fireplace 10009383IF WARRANTY SERVICE IS NEEDED… LIMITED LIFETIME WARRANTYPRODUCT COVERED BY THIS WARRANTY 2DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELFModel Efficiency RatingsCFM Corporation EnerGuide Ratings