Vermont Casting 33XDV/36XDV/39XDV continued, XDV Direct Vent Gas Fireplace, Description

Page 48
Fuel Conversion Kits

XDV Direct Vent Gas Fireplace

33XDV/36XDV/39XDV (continued)

Ref.

Description

33XDV

36XDV

39XDV

33b.

Orifice Pilot LP RF

--

20000907

n/a

34a.

Pilot Assembly Nat. RF

--

20002266

n/a

34b.

Pilot Assembly LP RF

--

20002268

n/a

35.

Thermopile (RF)

--

20002400

n/a

36.

Pilot Tubing w/Fittings PSE

--

10003279

n/a

37.

Ignitor Piezo Honeywell

--

20000062

n/a

38.

Valve SIT 820.662 (RN)

20010563

20010563

20010563

39.

Valve SIT EN

20011013

20011013

20011013

40.

Valve HW RFN Conv RV8310E

--

20003719

n/a

41.

Flexible Gas Line w/ON/OFF Shut-off

20002500

20002500

20002500

42.

Manifold Tubing w/fittings (not shown)

57318

57318

57318

43.

Fan Kit Assembly FK24 (Optional, not shown)

ZA1100

ZA1100

ZA1100

44.

Fan Kit Assembly FK12 (Optional, not shown)

ZA1110

ZA1110

ZA1110

45.

Fan w/Bracket

54103

54103

n/a

46.

Electrical Cord (6ft) Fan Kits

51865

51865

51865

47.

Fan Temperature Sensor (FK24)

51704

51704

51704

48.

Speed Control (FK24)

51738

51738

51738

49.

Speed Control Knob (FK24)

51882

51882

51882

50.

Remote Switch Wire Assembly

20010345

20010345

20010345

51.

Gasket Plate Air Inlet

10008179

10007706

10007706

52.

Gasket Plate Cover Flue Products

10002233

10002233

10002233

53.

Gasket Plate Cover Flue Pipe

10002237

10002237

10002237

54.

Gasket Burner Base

10007387

10007087

10007980

55.

Relief Plate Assembly (Burner Base)

10004192

10004192

10004192

56.

Relief Plate Assembly

10007396

10002429

10007967

57a.

Console Assembly RN/RP

10009153

10009153

10009153

57b.

Console Assembly RF

--

10009377

n/a

58.

Valve ON/OFF

10009138

10009138

10009138

59.

Transmitter

--

20002047

n/a

60.

Cord Set RF Valve

--

20002541

n/a

61.

Antennae HW395783-1 RFN/RFP Valve

--

20003561

n/a

62.

Shield Heat Pilot

10000248

10000248

10000248

63.

Ignition Control Synetek (EN)

10007939

10007939

10007939

64.

Wire Harness (EN) Synetek (low voltage)

10008139

10008139

10008139

65.

Wire Harness (EN) Synetek

10008140

10008140

10008140

66.

Electrical Cord (6ft) Ignition Control

10008298

10008298

10008298

67.

Clevis Pin

10008615

10008615

10008615

68.

Clip Pin Hitch

10008616

10008616

10008616

69.

Wire w/Terminals Assembly

10009179

10009179

10009179

70.

Knob Valve ON/OFF

76525

76525

76525

71.

Shield Pilot Front

10009404

10009154

--

Fuel Conversion Kits

Conversion Kit, NG to LP

33XDV

KIt # 10009427

36XDVRN/EN

Kit # 10009419

36XDVRFN

Kit # 10008276

39XDVRN

Kit # 20011505

39XDVEN

Kit # 20011504

Conversion Kit, LP to NG

33XDV

Kit # 10009429

36XDVRP/EP

Kit # 10009421

36XDVRFP

Kit # 10008277

39XDVRP

Kit # 20011506

48

10009383

Image 48
Contents Installation Instructions and Homeowner’s Manual INSTALLER/CONSUMER SAFETY INFORMATIONDirect Vent Models: 33XDV, 36XDV, 39XDV Table of Contents XDV Direct Vent Gas FireplaceInstallation & Operating Instructions MaintenanceInstallation & Operating Instructions Locating Your FireplaceXDV Direct Vent Gas Fireplace 10009383XDV Fireplace Dimensions - Installed as Rear Vent Framing DimensionsXDV Direct Vent Gas Fireplace 33XDVXDV Fireplace Dimensions - Installed as Top Vent Framing DimensionsXDV Direct Vent Gas Fireplace 33XDVClearance to Combustibles MantelsHearth Cold climate installation recommendationGas Line Installation Framing and FinishingFinal Finishing Gas SpecificationsRemote ON/OFF Switch Alternate Switch LocationEB-1Electrical Box XDV Direct Vent Gas FireplaceElectronic Gas Control Valve XDV Direct Vent Gas Fireplace10009383 Optional Top Vent Application XDV Direct Vent Gas Fireplace10009383 General Venting Top Vent Application Restrictor Plate33XDV Restrictor Plate Installation 36XDV Restrictor Plate InstallationCanadian Installations1 US Installations2XDV Direct Vent Gas Fireplace 10009383General Information Assembling Vent Pipes Flex Vent PipesCanadian Installations USA InstallationsHow to Use the Vent Graph Twist Lock PipesRear Wall Venting Applications XDV Direct Vent Gas FireplaceRear Wall Installation Twist Lock Pipe XDV Direct Vent Gas FireplaceSTEP STEPRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationsXDV Direct Vent Gas Fireplace StepXDV Direct Vent Gas Fireplace Total angular variation =10009383 Vertical Sidewall Installation Twist Lock Pipe XDV Direct Vent Gas FireplaceSTEP STEPVertical Sidewall Installation Flex Vent Pipe XDV Direct Vent Gas FireplaceSTEP STEPBelow Grade Installations Vertical Through-the-RoofApplicationXDV Direct Vent Gas Fireplace Do not backfill around snorkelVertical Through-the-RoofInstallation XDV Direct Vent Gas Fireplace10009383 XDV Direct Vent Gas Fireplace 10009383Typical Roof SupportTypical Ceiling ApplicationSupport ApplicationVenting Components XDV Direct Vent Gas FireplaceWindow Frame Assembly Removal Glass CleaningReplacement Of Ceramic Hearth Panels Operating InstructionsInstallation of Logs Log Identification Chart33XDV XDV Direct Vent Gas Fireplace36XDV XDV Direct Vent Gas Fireplace10009383 XDV Direct Vent Gas Fireplace 10009383Log Center Right B153 39XDV XDV Direct Vent Gas Fireplace10009383 XDV Direct Vent Gas Fireplace 10009383Burner Lava Rock Placement Flame & Temperature AdjustmentFlame Characteristics Large Lava RockXDV Direct Vent Gas Fireplace 33XDV36XDV 39XDVFOR YOUR SAFETY READ BEFORE LIGHTING Lighting and Operating InstructionsLighting Instructions To Turn Off Gas To HeaterFor Your Safety, Read the Following Warnings Lighting & Operating Instructionsbefore Lighting the Appliance Lighting InstructionsShut Off Procedure Instructions for RF Comfort Control ValveOperation Transmitter Operation Off ModeDelay Timer Mode Disable Thermostat FunctionTroubleshooting Auto ModeService Action XDV Direct Vent Gas FireplaceLED Count Replace valveXDV Direct Vent Gas Fireplace On PathLocal Path 10009383Troubleshooting the Gas Control System SYMPTOMXDV Direct Vent Gas Fireplace POSSIBLE CAUSESTroubleshooting the Gas Control System XDV Direct Vent Gas FireplaceNormal Operation Abnormal OperationXDV Direct Vent Gas Fireplace Honeywell ValveBurner Orifice Conversion 33/36XDV NOVA SIT820 ValveBurner Orifice Conversion 39XDV XDV Direct Vent Gas FireplacePilot Orifice Conversion 10009383Fuel Conversion Instructions Honeywell Comfort Control Valve ONLYInstallation Precautions Conversion Procedure39XDV XDV Direct Vent Gas FireplacePilot Orifice Conversion 10009383Table 1 Injector Orifice Size Matrix XDV Direct Vent Gas FireplaceConversion to Natural Gas Burner OrificeMaintenance Cleaning the Standing Pilot Control Systemfireplace has been in use. FK24/FK12 Fan Assembly XDV Direct Vent Gas Fireplace33XDV/36XDV/39XDV XDV Direct Vent Gas Fireplace10009383 33XDV/36XDV/39XDV continued XDV Direct Vent Gas FireplaceDescription 33XDV33XDV/36XDV/39XDV continued XDV Direct Vent Gas FireplaceDescription 33XDVOptional Accessories Available Hard Direct Wire Hook UpFan Kits Turn off all power before hook upRemote Controls Ceramic Refractory PanelsInstallation Instructions XDV Direct Vent Gas FireplaceOptional Trim Kits Screen Door KitFiligree Louvre Kit Arch/Square Face KitXDV Direct Vent Gas Fireplace 10009383XDV Direct Vent Gas Fireplace 10009383XDV Direct Vent Gas Fireplace 10009383LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTYIF WARRANTY SERVICE IS NEEDED… 2DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELFEfficiency Ratings CFM CorporationModel EnerGuide Ratings