NOTE: Refer to Figure 57 for bracket and bend loca- tions.

1.Place the log front right. Hold the log with the pointed end toward the left. Place on top of burner toward the right. Slide the log toward the front until it comes in contact with the bracket at the front of the burner housing behind the burner tube. (Fig. 59) Adjust the log until the pointed end on the left is aligned with the left edge of the bracket. (Fig. 60)

Figure 60

Left Edge

Rear Log Bracket

of Bracket

 

Stop

 

Bracket

 

Front Brackets

FP1607

Fig. 59 Burner brackets and bends.

Log Front Right

LG478

2. Place the log overlay. Hold the overlay with the flat side down and large cut out for the middle flame on the right. Set the overlay on top of the burner toward the left front inside the stop bracket on the left end and the bend on the front left of the burner. (Fig. 61) Rotate the right end of the overlay clockwise

until it makes contact with the back

of the log front right. NOTE: This is very critical as improper positioning of the over-

Figure 61

lay will affect the flameLG479 and the performance of the unit.

(Fig. 61)

Log Overlay

28

10009383

Image 28
Contents INSTALLER/CONSUMER SAFETY INFORMATION Installation Instructions and Homeowner’s ManualDirect Vent Models: 33XDV, 36XDV, 39XDV Table of Contents XDV Direct Vent Gas FireplaceInstallation & Operating Instructions MaintenanceInstallation & Operating Instructions Locating Your FireplaceXDV Direct Vent Gas Fireplace 10009383XDV Fireplace Dimensions - Installed as Rear Vent Framing DimensionsXDV Direct Vent Gas Fireplace 33XDVXDV Fireplace Dimensions - Installed as Top Vent Framing DimensionsXDV Direct Vent Gas Fireplace 33XDVClearance to Combustibles MantelsHearth Cold climate installation recommendationGas Line Installation Framing and FinishingFinal Finishing Gas SpecificationsRemote ON/OFF Switch Alternate Switch LocationEB-1Electrical Box XDV Direct Vent Gas FireplaceXDV Direct Vent Gas Fireplace Electronic Gas Control Valve10009383 XDV Direct Vent Gas Fireplace Optional Top Vent Application10009383 General Venting Top Vent Application Restrictor Plate33XDV Restrictor Plate Installation 36XDV Restrictor Plate InstallationCanadian Installations1 US Installations2XDV Direct Vent Gas Fireplace 10009383General Information Assembling Vent Pipes Flex Vent PipesCanadian Installations USA InstallationsHow to Use the Vent Graph Twist Lock PipesRear Wall Venting Applications XDV Direct Vent Gas FireplaceRear Wall Installation Twist Lock Pipe XDV Direct Vent Gas FireplaceSTEP STEPRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationsXDV Direct Vent Gas Fireplace StepTotal angular variation = XDV Direct Vent Gas Fireplace10009383 Vertical Sidewall Installation Twist Lock Pipe XDV Direct Vent Gas FireplaceSTEP STEPVertical Sidewall Installation Flex Vent Pipe XDV Direct Vent Gas FireplaceSTEP STEPBelow Grade Installations Vertical Through-the-RoofApplicationXDV Direct Vent Gas Fireplace Do not backfill around snorkelXDV Direct Vent Gas Fireplace Vertical Through-the-RoofInstallation10009383 XDV Direct Vent Gas Fireplace 10009383Typical Roof SupportTypical Ceiling ApplicationSupport ApplicationVenting Components XDV Direct Vent Gas FireplaceWindow Frame Assembly Removal Glass CleaningReplacement Of Ceramic Hearth Panels Operating Instructions Installation of Logs Log Identification Chart 33XDV XDV Direct Vent Gas FireplaceXDV Direct Vent Gas Fireplace 36XDV10009383 10009383 XDV Direct Vent Gas FireplaceLog Center Right B153 XDV Direct Vent Gas Fireplace 39XDV10009383 XDV Direct Vent Gas Fireplace 10009383Burner Lava Rock Placement Flame & Temperature AdjustmentFlame Characteristics Large Lava RockXDV Direct Vent Gas Fireplace 33XDV36XDV 39XDVFOR YOUR SAFETY READ BEFORE LIGHTING Lighting and Operating InstructionsLighting Instructions To Turn Off Gas To HeaterFor Your Safety, Read the Following Warnings Lighting & Operating Instructionsbefore Lighting the Appliance Lighting InstructionsShut Off Procedure Instructions for RF Comfort Control ValveOperation Transmitter Operation Off ModeDelay Timer Mode Disable Thermostat FunctionTroubleshooting Auto ModeService Action XDV Direct Vent Gas FireplaceLED Count Replace valveXDV Direct Vent Gas Fireplace On PathLocal Path 10009383Troubleshooting the Gas Control System SYMPTOMXDV Direct Vent Gas Fireplace POSSIBLE CAUSESTroubleshooting the Gas Control System XDV Direct Vent Gas FireplaceNormal Operation Abnormal OperationXDV Direct Vent Gas Fireplace Honeywell ValveBurner Orifice Conversion 33/36XDV NOVA SIT820 ValveBurner Orifice Conversion 39XDV XDV Direct Vent Gas FireplacePilot Orifice Conversion 10009383Fuel Conversion Instructions Honeywell Comfort Control Valve ONLYInstallation Precautions Conversion Procedure39XDV XDV Direct Vent Gas FireplacePilot Orifice Conversion 10009383Table 1 Injector Orifice Size Matrix XDV Direct Vent Gas FireplaceConversion to Natural Gas Burner OrificeMaintenance Cleaning the Standing Pilot Control Systemfireplace has been in use. FK24/FK12 Fan Assembly XDV Direct Vent Gas FireplaceXDV Direct Vent Gas Fireplace 33XDV/36XDV/39XDV10009383 33XDV/36XDV/39XDV continued XDV Direct Vent Gas FireplaceDescription 33XDV33XDV/36XDV/39XDV continued XDV Direct Vent Gas FireplaceDescription 33XDVOptional Accessories Available Hard Direct Wire Hook UpFan Kits Turn off all power before hook upRemote Controls Ceramic Refractory PanelsInstallation Instructions XDV Direct Vent Gas FireplaceOptional Trim Kits Screen Door KitFiligree Louvre Kit Arch/Square Face KitXDV Direct Vent Gas Fireplace 10009383XDV Direct Vent Gas Fireplace 10009383XDV Direct Vent Gas Fireplace 10009383LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTYIF WARRANTY SERVICE IS NEEDED… 2DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELFEfficiency Ratings CFM CorporationModel EnerGuide Ratings