CFM Corporation DVT38IN, DVT44IN Chateau, Canadian Installations1, US Installations2

Page 15
Canadian Installations1

Chateau™

General Venting Information - Termination Location

D

V

E

L

V

BUS Installations2

18” (458 mm) for non-vinyl soffitsC24” (610 mm) for vinyl soffits

V�����

������

F

V

��������

 

Manual backgroundBManual background

 

INSIDE

 

 

 

 

CORNER DETAIL

 

 

 

 

G

 

 

 

 

 

V

 

 

H

 

A

 

 

 

N

 

 

 

 

B

 

B

V

 

 

V

 

 

 

��������

�����

 

 

 

 

������

 

 

 

 

 

 

 

 

B

V

J X

B

 

M

 

 

Manual backgroundManual background NManual background

Manual background G

Manual background G

Manual background V

A

I

 

VManual background KManual backgroundX

Manual backgroundV

A

 

 

V VENT TERMINATION X AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

 

CFM145a

 

 

 

 

 

 

 

Canadian Installations1

US Installations2

 

 

A =

Clearance above grade, veranda, porch,

12” (30 cm)

 

12” (30 cm)

 

 

deck, or balcony

 

 

 

 

 

B = Clearance to window or door that may be

6” (15 cm) for appliances

6” (15 cm) for appliances

 

 

opened

< 10,000Btuh (3kW), 12” (30 cm)

< 10,000 Btuh (3kW), 9”

 

 

 

for appliances > 10,000 Btuh (3kW) and

(23 cm) for appliances > 10,000

 

 

 

< 100,000 Btuh (30kW), 36” (91 cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

C = Clearance to permanently closed window

12” (305 mm) recommended to

12” (305 mm) recommended to

 

 

 

prevent window condensation

prevent window condensation

 

D = Vertical clearance to ventilated soffit located

 

 

 

 

 

 

above the terminal within a horizontal

18” (458 mm) for non-vinyl soffits

18” (458 mm) for non-vinyl soffits

 

 

distance of 2 feet (610mm) from the center

24” (610 mm) for vinyl soffits

24” (610 mm) for vinyl soffits

 

 

line of the terminal

 

 

 

 

 

E = Clearance to unventilated soffit

24” (610 mm)

 

24” (610 mm)

 

F =

Clearance to outside corner

see next page

 

see next page

 

G = Clearance to inside corner (see next page)

see next page

 

see next page

 

H = Clearance to each inside of center line

3’ (91 cm) within a height of 15’

3’ (91 cm) within a height of 15’

 

 

extended above meter/regulator assembly

above the meter/regulator assembly

above the meter/regulator assy

 

I =

Clearance to service regulator vent outlet

3’ (91 cm)

 

3’ (91 cm)

 

J =

Clearance to nonmechanical air supply inlet

6” (15 cm) for appliances < 10,000

6” (15 cm) for appliances

 

 

to building or the combustion air inlet to any

Btuh (3kW), 12” (30cm) for

< 10,000 Btuh (3kW), 9”

 

 

other appliances

appliances > 10,000 Btuh (3kW) and <

(23 cm) for appliances > 10,000

 

 

 

100,000 Btuh (30kW), 36” (91 cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30 cm) for

 

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

K* =Clearance to a mechanical air supply inlet

6’ (1.83 m)

 

3’ (91 cm) above if within 10’

 

 

 

 

 

(3m) horizontally

 

L =

Clearance above paved sidewalk or paved

7’ (2.13 m)†

 

7’ (2.13 m)†

 

 

driveway located on public property

 

 

 

 

 

M = Clearance under veranda, porch, deck or

12” (30 cm)‡

 

12” (30 cm)‡

 

 

balcony

 

 

 

 

N = Clearance above a roof shall extend a minimum of 24” (610 mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450 mm).

1 In accordance with the current CSA-B149 Installation Codes

2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes

*Clearance to a mechanical air supply refers to an HRV or other mechanical device that brings fresh air into the living space, not a fresh air for an appliance combustion.

† A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings

‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances.

2.The special venting system used on Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and approved by the listing agency.

3.CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

Fig. 12 Vent termination clearances.

Image 15
Contents Chateau Installation Instructions and Homeowner’s ManualModel: DVT38IN, DVT44IN INSTALLER/CONSUMER SAFETY INFORMATIONTable of Contents Chateau20011956 20011956 Installation & Operating InstructionsChateau DVT38IN / DVT44IN Certified To20011956 Fireplace Dimensions - DVT38INFireplace Dimensions - DVT44IN ChateauMantels ChateauLocating Your Fireplace Clearance to CombustiblesChateau HearthFraming and Finishing Final FinishingHigh Elevations Gas Line InstallationGas Specifications Gas Inlet and Manifold PressuresChateau Control System InstallationElectrical Junction Box Control SystemSpecial Feature for Cold Climates Chateau20011956 Chateau Remote Control Transmitter Operating InstructionsON H/L MODEManual Function Setting F / C ScaleSetting Desired Room Temperature ChateauChateau CONTINUOUS PILOT FEATURECP CHILDPROOF FEATURE SETTING “LOCK-OUT”- CP20011956 Thermostatic Updating FeatureChateau Operational Notes20011956 General VentingChateau Location of Vent Termination18” 458 mm for non-vinylsoffits Canadian Installations1US Installations2 ChateauChateau Termination Clearances20011956 Vertical Termination General Information Assembling Vent PipesSK8 Venting Pipes Horizontal TerminationChateau Sidewall ApplicationsUse of the Restrictor Plates in Horizontal Venting ApplicationsSTEP Sidewall InstallationChateau STEPChateau STEP20011956 Chateau Vertical Through-the-Roof ApplicationsUse of Restrictor Plate for Vertical Venting ApplicationsVertical Through-the-RoofInstallation Chateau20011956 Min 2 610mm Attic InstallationCeiling Installation ChateauDescription Chimney ComponentsChateau ComponentOperating Instructions Glass Frame Assembly RemovalGlass Cleaning Restrictor Plate InstallationKit Model Ceramic Refractory InstallationChateau Appliance20011956 Log, Lava Rock and Ember PlacementChateau DVT38IN LogsChateau DVT44IN Logs20011956 Chateau 9.Position the Log Rear Left20011956 Chateau 12. Position the Log Front Middle Right20011956 Fig. 49 DVT44IN logset complete Chateau20011956 Fig. 48 DVT38IN logset completeDVT44 Flame CharacteristicsChateau DVT38Fig. 53 Trim frame in place Trim InstallationChateau 20011956Lighting Instructions For Your Safety, Read the Following WarningsLighting & Operating Instructions before Lighting the Appliance20011956 TroubleshootingChateau American Flame Gas Control SystemChateau Main flame will not light20011956 What to Check American Flame Gas Control System Error CodesChateau What to CheckChateau Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsChateau Converting the Gas Control Valve20011956 Injector Orifice Size Matrix Table 2 Air Shutter SettingsPilot Flame Adjustment Table20011956 MaintenanceCleaning the Control System Chateau20011956 DVT38IN, DVT44INFor Units GFYN5Q0, GFYN500 ChateauDVT38IN DVT38IN, DVT44IN continuedChateau DescriptionDVT38IN DVT38IN, DVT44IN continuedChateau DescriptionChateau AccessoriesBack-upBattery Kit Ceramic Refractory Kits20011956 ChateauBASIC ONE-YEARWARRANTY LIMITED LIFETIME WARRANTYIF WARRANTY SERVICE IS NEEDED LIMITED LIFETIME WARRANTYCFM Corporation Efficiency Ratings