Troubleshooting

Chateau™

Troubleshooting

American Flame Gas Control System

If erratic system behavior is observed that cannot be resolved by the methods outlined below, ensure that there is not a transmitter with batteries installed that may be interfering. If a transmitter is packed with batteries installed, its buttons may be depressed sending a constant signal which can interfere with the transmission of desired signals. A transmitter with new batteries can have a range of over 100’ (30.4 m).

Module will not learn trans- mitter

Ensure the REMOTE/OFF switch on the side of the module is set to REMOTE.

Make sure the batteries in both the transmitter and receiver are installed in the proper direction and are not drained. Individual battery voltage should be no less than 1.4V for AA and AAA batteries, 2.8V for button cells, and 9,0V for 12V batter- ies.

Verify the transmitter indicates a signal is being sent. With thermostat transmit- ters, the LCD display should indicate ON or OFF depending on which button is being pressed. The LED indicator should illuminate on wall transmitters and on/off hand-held transmitters. Buttons should be pressed and held for 1 to 2 seconds to ensure a complete signal is sent.

Make sure the transmitter is within the 20’ (6 m) operational range of the receiver.

Ensure the 4-pin lead-set is securely connected from the battery pack to the control module’s AUX connection. If the A/C power adapter is used, make sure the leads from the adapter are securely connected to the POWER terminals on the control module.

 

Press and hold the LEARN button on the module for approximately 10 seconds

 

to clear the memory (you should hear a series of beeps from the receiver). Then

 

press and release the learn button (you should hear a single beep from the

 

receiver), immediately press either the ON or OFF button on the transmitter (you

 

should hear a series of beeps indicating the transmitter code has been learned).

 

 

Pilot will not light/stay lit

Verify the gas supply is turned on.

 

Verify the receiver is receiving the signal from the transmitter by listening for a

 

beep from the receiver when ON is pressed on the transmitter. If you do not hear

 

a beep, ensure the module has learned the transmitter (see above).

 

Ensure the orange lead from the pilot assembly igniter is securely connected to

 

the terminal labeled “I” and the white lead from the flame rectification sensor is

 

securely connected to the terminal labeled “S” on the control module.

 

Make sure the orange and white leads from the module are securely connected to

 

the terminals labeled “PILOT” on the valve body.

 

Ensure the black GROUND wire is securely connected to an appropriate metal

 

portion of the valve or pilot assembly. A proper ground is essential to spark

 

igniter operation.

 

Make certain the pilot flame is in contact with the flame rectification sensor on the

 

pilot assembly. This valve is equipped with a pilot flame adjustment screw. If the

 

pilot flame is too small it will not contact the flame rectification sensor and will not

 

complete the safety circuit.

Pilot flame is always on/ will

Ensure the CONTINUOUS PILOT switch on the control module is set to OFF.

not extinguish

Check the handheld transmitter display for the word “PILOT” on the LCD screen. If

 

 

this is displayed, press and hold the CONTINUOUS PILOT button on the hand-

 

held transmitter for approximately 10 seconds to turn off continuous pilot mode.

20011956

35

Image 35
Contents Chateau Installation Instructions and Homeowner’s ManualModel: DVT38IN, DVT44IN INSTALLER/CONSUMER SAFETY INFORMATION20011956 Table of ContentsChateau 20011956 Installation & Operating InstructionsChateau DVT38IN / DVT44IN Certified To20011956 Fireplace Dimensions - DVT38INFireplace Dimensions - DVT44IN ChateauMantels ChateauLocating Your Fireplace Clearance to CombustiblesChateau HearthFraming and Finishing Final FinishingHigh Elevations Gas Line InstallationGas Specifications Gas Inlet and Manifold PressuresChateau Control System InstallationElectrical Junction Box Control System20011956 Special Feature for Cold ClimatesChateau Chateau Remote Control Transmitter Operating InstructionsON H/L MODEManual Function Setting F / C ScaleSetting Desired Room Temperature ChateauChateau CONTINUOUS PILOT FEATURECP CHILDPROOF FEATURE SETTING “LOCK-OUT”- CP20011956 Thermostatic Updating FeatureChateau Operational Notes20011956 General VentingChateau Location of Vent Termination18” 458 mm for non-vinylsoffits Canadian Installations1US Installations2 Chateau20011956 ChateauTermination Clearances Vertical Termination General Information Assembling Vent PipesSK8 Venting Pipes Horizontal TerminationChateau Sidewall ApplicationsUse of the Restrictor Plates in Horizontal Venting ApplicationsSTEP Sidewall InstallationChateau STEP20011956 ChateauSTEP Chateau Vertical Through-the-Roof ApplicationsUse of Restrictor Plate for Vertical Venting Applications20011956 Vertical Through-the-RoofInstallationChateau Min 2 610mm Attic InstallationCeiling Installation ChateauDescription Chimney ComponentsChateau ComponentOperating Instructions Glass Frame Assembly RemovalGlass Cleaning Restrictor Plate InstallationKit Model Ceramic Refractory InstallationChateau Appliance20011956 Log, Lava Rock and Ember PlacementChateau DVT38IN Logs20011956 ChateauDVT44IN Logs 20011956 Chateau9.Position the Log Rear Left 20011956 Chateau12. Position the Log Front Middle Right Fig. 49 DVT44IN logset complete Chateau20011956 Fig. 48 DVT38IN logset completeDVT44 Flame CharacteristicsChateau DVT38Fig. 53 Trim frame in place Trim InstallationChateau 20011956Lighting Instructions For Your Safety, Read the Following WarningsLighting & Operating Instructions before Lighting the Appliance20011956 TroubleshootingChateau American Flame Gas Control System20011956 ChateauMain flame will not light What to Check American Flame Gas Control System Error CodesChateau What to CheckChateau Conversion PrecautionsConversion Procedure Fuel Conversion Instructions20011956 ChateauConverting the Gas Control Valve Injector Orifice Size Matrix Table 2 Air Shutter SettingsPilot Flame Adjustment Table20011956 MaintenanceCleaning the Control System Chateau20011956 DVT38IN, DVT44INFor Units GFYN5Q0, GFYN500 ChateauDVT38IN DVT38IN, DVT44IN continuedChateau DescriptionDVT38IN DVT38IN, DVT44IN continuedChateau DescriptionChateau AccessoriesBack-upBattery Kit Ceramic Refractory Kits20011956 ChateauBASIC ONE-YEARWARRANTY LIMITED LIFETIME WARRANTYIF WARRANTY SERVICE IS NEEDED LIMITED LIFETIME WARRANTYCFM Corporation Efficiency Ratings