CFM Corporation DVT38IN, DVT44IN Chateau, Converting the Gas Control Valve, 20011956

Page 39
Converting the Gas Control Valve

Index Tab

Allen Wrench

 

Snap Ring

CO134

Fig. 56 Remove pilot orifice.

10.Install the conversion orifice.

11.Reinstall pilot hood. Be sure to align hood with index tab.

Converting the Gas Control Valve

The AF4000 electronic control valve is convertible from natural gas to propane gas by changing the minimum rate screw in the valve and by rotating a plastic knob located under a black cap on the top face of the valve.

1.Refer to Control System Installation section on Page 8 for instructions to gain access to the electronic control valve.

2.Remove the black cap by pulling the cap straight off. Note the position of the marker on the top of the rotary knob. This marker will point to NAT or LP. (Fig. 57)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Type

 

Marker

Minimum Rate

CO137

Screw

 

Fig. 57 Remove black plastic cap and adjust rotary knob to correct gas type. (LP position shown) Replace minimum rate screw with one supplied in coversion kit.

3.To convert the valve from NG to LP, push in the knob and rotate 90° (1/4 turn). NOTE: The shaft should point to LP and the shaft will remain pushed in.

4.Remove the minimum rate screw, using a small screwdriver, located in the valve next to the motor

drive. (Fig. 57)

Chateau™

5.Replace the minimum rate screw with the one provided in the LP conversion kit supplied with this fireplace. Ensure the screw is fully installed.

6.After the conversion has been made, check the manifold outlet pressure with a manometer at the test ports located at the right side front edge of the fireplace opening. The lower test port is manifold outlet pressure.

CAUTION: Turn off the gas supply before removing test port plug.

Check Manifold Pressure

7.Using a 7/16” nut driver, remove the threaded plug from the test port.

8.Thread the supplied brass extension adaptor fully into the open test port.

9.Attach a 1/4” diameter pressure gauge flexible hose fully onto the barb of the adaptor.

10.Turn on gas supply and operate valve with remote control as needed to indicate gas pressure. The manifold pressure for LP should be 10” wcp. The manifold pressure for NG should be 3.5” wcp.

CAUTION: Turn off the valve and gas sup- ply before removing test port adaptor and replacing plug.

11. After test, remove adaptor and replace plug.

12 . Turn on gas supply and check that plugs are tight and leak free.

13.Install the enclosed identification label to the valve body where it can easily be seen.

14.Test for Leaks

Apply gas to the system and light the pilot.

With a soapy solution check for leaks around the pilot assembly where the tube enters the pilot as- sembly. Tighten fitting if necessary.

With the main burner “ON” check for leaks around the burner orifice. Be careful of the burner flame. Tighten orifice if necessary.

15.Replace burner to original position.

16.Replace burner leg.

17.Replace burner tube and fettle.

18.Follow instructions starting on Page 27 to reinstall logs, lava rock, volcanic rock and embers.

19.Replace glass frame.

20011956

39

Image 39
Contents Chateau Installation Instructions and Homeowner’s ManualModel: DVT38IN, DVT44IN INSTALLER/CONSUMER SAFETY INFORMATIONTable of Contents Chateau20011956 20011956 Installation & Operating InstructionsChateau DVT38IN / DVT44IN Certified To20011956 Fireplace Dimensions - DVT38INFireplace Dimensions - DVT44IN ChateauMantels ChateauLocating Your Fireplace Clearance to CombustiblesChateau HearthFraming and Finishing Final FinishingHigh Elevations Gas Line InstallationGas Specifications Gas Inlet and Manifold PressuresChateau Control System InstallationElectrical Junction Box Control SystemSpecial Feature for Cold Climates Chateau20011956 Chateau Remote Control Transmitter Operating InstructionsON H/L MODEManual Function Setting F / C ScaleSetting Desired Room Temperature ChateauChateau CONTINUOUS PILOT FEATURECP CHILDPROOF FEATURE SETTING “LOCK-OUT”- CP20011956 Thermostatic Updating FeatureChateau Operational Notes20011956 General VentingChateau Location of Vent Termination18” 458 mm for non-vinylsoffits Canadian Installations1US Installations2 ChateauChateau Termination Clearances20011956 Vertical Termination General Information Assembling Vent PipesSK8 Venting Pipes Horizontal TerminationChateau Sidewall ApplicationsUse of the Restrictor Plates in Horizontal Venting ApplicationsSTEP Sidewall InstallationChateau STEPChateau STEP20011956 Chateau Vertical Through-the-Roof ApplicationsUse of Restrictor Plate for Vertical Venting ApplicationsVertical Through-the-RoofInstallation Chateau20011956 Min 2 610mm Attic InstallationCeiling Installation ChateauDescription Chimney ComponentsChateau ComponentOperating Instructions Glass Frame Assembly RemovalGlass Cleaning Restrictor Plate InstallationKit Model Ceramic Refractory InstallationChateau Appliance20011956 Log, Lava Rock and Ember PlacementChateau DVT38IN LogsChateau DVT44IN Logs20011956 Chateau 9.Position the Log Rear Left20011956 Chateau 12. Position the Log Front Middle Right20011956 Fig. 49 DVT44IN logset complete Chateau20011956 Fig. 48 DVT38IN logset completeDVT44 Flame CharacteristicsChateau DVT38Fig. 53 Trim frame in place Trim InstallationChateau 20011956Lighting Instructions For Your Safety, Read the Following WarningsLighting & Operating Instructions before Lighting the Appliance20011956 TroubleshootingChateau American Flame Gas Control SystemChateau Main flame will not light20011956 What to Check American Flame Gas Control System Error CodesChateau What to CheckChateau Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsChateau Converting the Gas Control Valve20011956 Injector Orifice Size Matrix Table 2 Air Shutter SettingsPilot Flame Adjustment Table20011956 MaintenanceCleaning the Control System Chateau20011956 DVT38IN, DVT44INFor Units GFYN5Q0, GFYN500 ChateauDVT38IN DVT38IN, DVT44IN continuedChateau DescriptionDVT38IN DVT38IN, DVT44IN continuedChateau DescriptionChateau AccessoriesBack-upBattery Kit Ceramic Refractory Kits20011956 ChateauBASIC ONE-YEARWARRANTY LIMITED LIFETIME WARRANTYIF WARRANTY SERVICE IS NEEDED LIMITED LIFETIME WARRANTYCFM Corporation Efficiency Ratings