CFM Corporation DVT38IN, DVT44IN Installation & Operating Instructions, Chateau, 20011956

Page 3
Installation & Operating Instructions

Chateau™

Installation & Operating Instructions

This gas fireplace must be installed by a qualified installer, preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54.

In the Commonwealth of Massachusetts:

All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.

A carbon monoxide detector must be installed in the same room as the fireplace. (Refer to Regulation 248CMR 4.00 & 5.00 for more information.)

FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING:

1 . This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.Children and adults should be alerted to the hazards of the high surface temperatures of this fireplace and should stay away to avoid burns or ignition of clothing.

3.CAUTION: Due to high glass surface temperature chil- dren should be carefully supervised when in the same room as fireplace.

�������

��������������

������������

������������������

�������������

��������������������

���������������

4.Under no circumstances should this fireplace be modified. Parts removed for servicing should be replaced prior to operating this fireplace again.

5.A professional service person should be contacted to inspect the fireplace annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc.

6.Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this fireplace.

7.The venting system (chimney) of this fireplace should be checked at least once a year and if needed your venting system should be cleaned.

8.Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. This fireplace should not be used as a drying rack for cloth- ing, nor should Christmas stockings or decorations be hung on or around the fireplace.

9.Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this fireplace.

10.The flow of combustion and ventilation air must not be obstructed in any way.

11.When the fireplace is installed directly on carpeting, vinyl tile or any combustible material other than wood, this

fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace.

12.This fireplace requires adequate ventilation and combustion air to operate properly.

13.This fireplace must not be connected to a chimney flue serving a separate solid fuel burning fireplace.

14.When the fireplace is not in use it is recommended that the gas control valve be left in the “OFF” position.

15.For operation during power outages, the installation of the optional battery back-up kit Model DVTBBK is recommended at initial installation.

This appliance has been designed, certified and ap- proved to be installed indoors only.

DVT38IN / DVT44IN

Certified To

ANSI Z21.50b-2002/CSA 2.22b-2002

Vented Gas Fireplace

WARNING: Check with your electronics manufacturer before installing a television or other electronic de- vice above this fireplace.

This appliance may be installed in an aftermarket permanently located, manufactured home or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

The DVT38/44 has been approved for mobile home installations.

IMPORTANT:

PLEASE REVIEW THE FOLLOWING CAREFULLY

Remove any plastic from parts before turning the fire- place ON.

It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufac- turing process.

Please ensure that your room is well ventilated- open all windows.

It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it.

Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6

20011956

3

Image 3
Contents Chateau Installation Instructions and Homeowner’s ManualModel: DVT38IN, DVT44IN INSTALLER/CONSUMER SAFETY INFORMATIONTable of Contents Chateau20011956 20011956 Installation & Operating InstructionsChateau DVT38IN / DVT44IN Certified To20011956 Fireplace Dimensions - DVT38INFireplace Dimensions - DVT44IN ChateauMantels ChateauLocating Your Fireplace Clearance to CombustiblesChateau HearthFraming and Finishing Final FinishingHigh Elevations Gas Line InstallationGas Specifications Gas Inlet and Manifold PressuresChateau Control System InstallationElectrical Junction Box Control SystemSpecial Feature for Cold Climates Chateau20011956 Chateau Remote Control Transmitter Operating InstructionsON H/L MODEManual Function Setting F / C ScaleSetting Desired Room Temperature ChateauChateau CONTINUOUS PILOT FEATURECP CHILDPROOF FEATURE SETTING “LOCK-OUT”- CP20011956 Thermostatic Updating FeatureChateau Operational Notes20011956 General VentingChateau Location of Vent Termination18” 458 mm for non-vinylsoffits Canadian Installations1US Installations2 ChateauChateau Termination Clearances20011956 Vertical Termination General Information Assembling Vent PipesSK8 Venting Pipes Horizontal TerminationChateau Sidewall ApplicationsUse of the Restrictor Plates in Horizontal Venting ApplicationsSTEP Sidewall InstallationChateau STEPChateau STEP20011956 Chateau Vertical Through-the-Roof ApplicationsUse of Restrictor Plate for Vertical Venting ApplicationsVertical Through-the-RoofInstallation Chateau20011956 Min 2 610mm Attic InstallationCeiling Installation ChateauDescription Chimney ComponentsChateau ComponentOperating Instructions Glass Frame Assembly RemovalGlass Cleaning Restrictor Plate InstallationKit Model Ceramic Refractory InstallationChateau Appliance20011956 Log, Lava Rock and Ember PlacementChateau DVT38IN LogsChateau DVT44IN Logs20011956 Chateau 9.Position the Log Rear Left20011956 Chateau 12. Position the Log Front Middle Right20011956 Fig. 49 DVT44IN logset complete Chateau20011956 Fig. 48 DVT38IN logset completeDVT44 Flame CharacteristicsChateau DVT38Fig. 53 Trim frame in place Trim InstallationChateau 20011956Lighting Instructions For Your Safety, Read the Following WarningsLighting & Operating Instructions before Lighting the Appliance20011956 TroubleshootingChateau American Flame Gas Control SystemChateau Main flame will not light20011956 What to Check American Flame Gas Control System Error CodesChateau What to CheckChateau Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsChateau Converting the Gas Control Valve20011956 Injector Orifice Size Matrix Table 2 Air Shutter SettingsPilot Flame Adjustment Table20011956 MaintenanceCleaning the Control System Chateau20011956 DVT38IN, DVT44INFor Units GFYN5Q0, GFYN500 ChateauDVT38IN DVT38IN, DVT44IN continuedChateau DescriptionDVT38IN DVT38IN, DVT44IN continuedChateau DescriptionChateau AccessoriesBack-upBattery Kit Ceramic Refractory Kits20011956 ChateauBASIC ONE-YEARWARRANTY LIMITED LIFETIME WARRANTYIF WARRANTY SERVICE IS NEEDED LIMITED LIFETIME WARRANTYCFM Corporation Efficiency Ratings