Gas Specifications

Gas Specifications

 

 

 

Max.

Min.

 

 

Gas

Input

Input

Model

Fuel

Control

BTU/hr

BTU/hr

DVT38IN

Natural Gas

American Flame

46,000

32,000

DVT38IP

Propane

AF-4034

46,000

36,000

DVT44IN

Natural Gas

with

60,000

37,000

DVT44IP

Propane

7.5V DC Hi/Lo

60,000

45,000

Gas Inlet and Manifold Pressures

 

Natural

LP (Propane)

Minimum Inlet Pressure

5.5” w.c.

11.0” w.c.

Maximum Inlet Pressure

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

 

 

 

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level.

For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370 m).

WARNING: Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

Chateau™

Gas Line Installation

When purging gas line the front glass must be removed.

A gas shut off valve must be installed on the gas pipe line going into the appliance within easy access. Refer to local codes.

The gas pipeline can be brought in through the top of the valve box assembly.

The gas line connection can be made with properly tinned 1/2” copper tubing or 1/2” gas tight. Some municipalities have additional local codes, it is always best to consult your local authority and the CSA-B149.1installation codes.

For USA installations consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.

 

 

1/2” NPT X 1/2” Flare

 

 

Shut-off Valve

 

 

 

 

1/2” Gas Tight or

 

 

 

Tinned Copper

 

 

 

(from valve)

FP297A

1/2” Gas Supply

(Not provided)

 

 

Fig. 7

Typical gas supply installation.

 

Always check for gas leaks with a mild soap and water solution applied with a brush no larger than 1” (25 mm). Never apply soap and water solution with a spray bottle. Do not use an open flame for leak testing.

The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this or any other gas appliance control from the gas line when pressure testing.

The fireplace is equipped with an inlet and manifold pressure test point, therefore it is not necessary to pro- vide a 1/8” test point up stream of the control.

When using copper, use only approved fittings. Always provide a union when using black iron pipe so the gas line can be easily disconnected for burner servicing. A union may not be behind a wall. Refer to the gas speci- fications for pressure details and ratings.

20011956

7

Image 7
Contents Chateau Installation Instructions and Homeowner’s ManualModel: DVT38IN, DVT44IN INSTALLER/CONSUMER SAFETY INFORMATIONChateau Table of Contents20011956 20011956 Installation & Operating InstructionsChateau DVT38IN / DVT44IN Certified To20011956 Fireplace Dimensions - DVT38INFireplace Dimensions - DVT44IN ChateauMantels ChateauLocating Your Fireplace Clearance to CombustiblesChateau HearthFraming and Finishing Final FinishingHigh Elevations Gas Line InstallationGas Specifications Gas Inlet and Manifold PressuresChateau Control System InstallationElectrical Junction Box Control SystemChateau Special Feature for Cold Climates20011956 Chateau Remote Control Transmitter Operating InstructionsON H/L MODEManual Function Setting F / C ScaleSetting Desired Room Temperature ChateauChateau CONTINUOUS PILOT FEATURECP CHILDPROOF FEATURE SETTING “LOCK-OUT”- CP20011956 Thermostatic Updating FeatureChateau Operational Notes20011956 General VentingChateau Location of Vent Termination18” 458 mm for non-vinylsoffits Canadian Installations1US Installations2 ChateauTermination Clearances Chateau20011956 Vertical Termination General Information Assembling Vent PipesSK8 Venting Pipes Horizontal TerminationChateau Sidewall ApplicationsUse of the Restrictor Plates in Horizontal Venting ApplicationsSTEP Sidewall InstallationChateau STEPSTEP Chateau20011956 Chateau Vertical Through-the-Roof ApplicationsUse of Restrictor Plate for Vertical Venting ApplicationsChateau Vertical Through-the-RoofInstallation20011956 Min 2 610mm Attic InstallationCeiling Installation ChateauDescription Chimney ComponentsChateau ComponentOperating Instructions Glass Frame Assembly RemovalGlass Cleaning Restrictor Plate InstallationKit Model Ceramic Refractory InstallationChateau Appliance20011956 Log, Lava Rock and Ember PlacementChateau DVT38IN LogsDVT44IN Logs Chateau20011956 9.Position the Log Rear Left Chateau20011956 12. Position the Log Front Middle Right Chateau20011956 Fig. 49 DVT44IN logset complete Chateau20011956 Fig. 48 DVT38IN logset completeDVT44 Flame CharacteristicsChateau DVT38Fig. 53 Trim frame in place Trim InstallationChateau 20011956Lighting Instructions For Your Safety, Read the Following WarningsLighting & Operating Instructions before Lighting the Appliance20011956 TroubleshootingChateau American Flame Gas Control SystemMain flame will not light Chateau20011956 What to Check American Flame Gas Control System Error CodesChateau What to CheckChateau Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsConverting the Gas Control Valve Chateau20011956 Injector Orifice Size Matrix Table 2 Air Shutter SettingsPilot Flame Adjustment Table20011956 MaintenanceCleaning the Control System Chateau20011956 DVT38IN, DVT44INFor Units GFYN5Q0, GFYN500 ChateauDVT38IN DVT38IN, DVT44IN continuedChateau DescriptionDVT38IN DVT38IN, DVT44IN continuedChateau DescriptionChateau AccessoriesBack-upBattery Kit Ceramic Refractory Kits20011956 ChateauBASIC ONE-YEARWARRANTY LIMITED LIFETIME WARRANTYIF WARRANTY SERVICE IS NEEDED LIMITED LIFETIME WARRANTYCFM Corporation Efficiency Ratings