CFM Corporation DVT44IN Electrical Junction Box, Control System Installation, Chateau

Page 8
Electrical Junction Box

Chateau™

Electrical Junction Box

The fireplace, when installed, must be elec- trically connected and grounded in accord- ance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or the national electrical code ANSI/NFPA No. 70 in the USA.

It is strongly suggested that the wiring of the Electrical Junction Box be carried out by a licensed electrician.

Ensure the power to the supply line has been disconnected before commencing this procedure.

Control System

The gas control system is located on the right hand side of the firebox behind an access panel and the decora- tive brick panel. The fireplace is operated using only the hand held remote control unit. The system wiring diagram is shown in Figure 11. NOTE: If you choose to install the optional battery back-up, (Model DVT- BBK), refer to Item #16 in the next section.

Control System Installation

1.Locate the fireplace in the desired location.

2.Remove the glass. Refer to Glass Frame Assembly Removal section.

3.If installed, remove the lava rock, volcanic rock, andirons, embers and logs, making note of each log’s location.

4.If installed, remove the refractory brick panel right side and rear pieces.

5.Using a back-up wrench, disconnect the gas supply fitting near the right rear corner of the firebox. (Fig. 8)

Pressure Test Ports

Gas Supply Fitting

Cover Plate

FP1793

Fig. 8 Disconnect gas supply fitting and remove 13 screws securing the cover plate.

6.Remove pilot assembly from burner assembly by removing two (2) screws.

7.Carefully slide the burner assembly to the left out of the way, taking care not to bend or break the pilot tubes or wiring.

8.Remove 13 screws around the perimeter holding large access panel on the right hand side of the firebox.

9.Carefully pull back the panel just enough to gain access to control box.

10.Connect the gas supply to the valve. (Fig. 9) Be sure to use a back-up wrench when tightening sup- ply fitting.

Gas Supply

Fitting

FP1794

Fig. 9 Connect gas supply to valve.

11.Connect a 120V AC electrical supply to the junc- tion box duplex outlet. Use a Romex-type strain relief connector when running wires out through the box knockout. Replace the duplex outlet and cover plate.

12.Plug the AC adaptor plug into the duplex outlet.

13.This control system must now be programmed to the hand held remote control transmitter. To pro- gram the remote control, make sure the 120V AC is connected and powered to the fireplace.

14.Remove the battery door on the back of the hand held remote control and install two (2) supplied “AAA” batteries. Be sure to note correct polarity. Replace battery door.

15.Locate the learn button on the main module. (Fig. 10) Press and release the learn button using a pencil point. There will be a beep sound from the module. Then press any key on the remote control transmitter. Once the module’s internal receiver ac- cepts the transmitter code, there will be a series of confirming beeps.

8

20011956

Image 8
Contents Installation Instructions and Homeowner’s Manual Model: DVT38IN, DVT44ININSTALLER/CONSUMER SAFETY INFORMATION Chateau20011956 Table of ContentsChateau Installation & Operating Instructions ChateauDVT38IN / DVT44IN Certified To 20011956Fireplace Dimensions - DVT38IN Fireplace Dimensions - DVT44INChateau 20011956Chateau Locating Your FireplaceClearance to Combustibles MantelsHearth Framing and FinishingFinal Finishing ChateauGas Line Installation Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsControl System Installation Electrical Junction BoxControl System Chateau20011956 Special Feature for Cold ClimatesChateau Remote Control Transmitter Operating Instructions ON H/LMODE ChateauSetting F / C Scale Setting Desired Room TemperatureChateau Manual FunctionCONTINUOUS PILOT FEATURE CP CHILDPROOF FEATURESETTING “LOCK-OUT”- CP ChateauThermostatic Updating Feature ChateauOperational Notes 20011956General Venting ChateauLocation of Vent Termination 20011956Canadian Installations1 US Installations2Chateau 18” 458 mm for non-vinylsoffits20011956 ChateauTermination Clearances General Information Assembling Vent Pipes SK8 Venting PipesHorizontal Termination Vertical TerminationSidewall Applications Use of the Restrictor Plates inHorizontal Venting Applications ChateauSidewall Installation ChateauSTEP STEP20011956 ChateauSTEP Vertical Through-the-Roof Applications Use of Restrictor Platefor Vertical Venting Applications Chateau20011956 Vertical Through-the-RoofInstallationChateau Attic Installation Ceiling InstallationChateau Min 2 610mmChimney Components ChateauComponent DescriptionGlass Frame Assembly Removal Glass CleaningRestrictor Plate Installation Operating InstructionsCeramic Refractory Installation ChateauAppliance Kit ModelLog, Lava Rock and Ember Placement ChateauDVT38IN Logs 2001195620011956 ChateauDVT44IN Logs 20011956 Chateau9.Position the Log Rear Left 20011956 Chateau12. Position the Log Front Middle Right Chateau 20011956Fig. 48 DVT38IN logset complete Fig. 49 DVT44IN logset completeFlame Characteristics ChateauDVT38 DVT44Trim Installation Chateau20011956 Fig. 53 Trim frame in placeFor Your Safety, Read the Following Warnings Lighting & Operating Instructionsbefore Lighting the Appliance Lighting InstructionsTroubleshooting ChateauAmerican Flame Gas Control System 2001195620011956 ChateauMain flame will not light American Flame Gas Control System Error Codes ChateauWhat to Check What to CheckConversion Precautions Conversion ProcedureFuel Conversion Instructions Chateau20011956 ChateauConverting the Gas Control Valve Table 2 Air Shutter Settings Pilot Flame AdjustmentTable Injector Orifice Size MatrixMaintenance Cleaning the Control SystemChateau 20011956DVT38IN, DVT44IN For Units GFYN5Q0, GFYN500Chateau 20011956DVT38IN, DVT44IN continued ChateauDescription DVT38INDVT38IN, DVT44IN continued ChateauDescription DVT38INAccessories Back-upBattery KitCeramic Refractory Kits ChateauChateau 20011956LIMITED LIFETIME WARRANTY IF WARRANTY SERVICE IS NEEDEDLIMITED LIFETIME WARRANTY BASIC ONE-YEARWARRANTYEfficiency Ratings CFM Corporation