Page 15

INSTALLATION

sions, in the same manner as shown in

1) Situate the chimney in a convenient loca-

diagram 10.

tion as near as possible to the appliance

 

outlet. Cut and frame a hole in the roof for

 

the support. The sides of this hole must be

 

vertical with 1 1/4" clearance.

 

 

2) Place the support in the opening. Lower it

 

to the correct height as determined by the

 

table and diagram below.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slope

 

"X"

 

 

 

 

 

 

 

 

 

 

 

0/12

- 2/12

 

4"

 

 

 

 

 

2/12

- 7/12

 

5-1/2"

 

 

 

 

 

7/12

- 12/12

 

6-3/4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12/12 - 24/12

 

7-1/2"

 

 

 

 

 

 

 

 

 

24/12+

 

12-1/2"

 

 

 

 

 

 

 

 

 

Diagram 13

Offset Chart

6)Twist lock the fl ue cap on to the last sec- tion.

Support Extensions - Round

(RDSE) or Square (SQSE)

Steep pitched cathedral ceilings may require the use of a support extension. This piece fi ts down inside the support and can be adjusted to increase the support's length by up to 22". The extension is attached to the support using the eight metal screws provided. Be sure there is at least a 2 inch overlap where the extension joins the support.

GAS CONNECTION

The gas connection is a 3/8" NPT 90o elbow. The gas line can be rigid pipe or to make in- stallation easier, use a listed fl exible connector and/or copper tubing if allowed by local codes. Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149

b)Any occupied areas above the fi rst fl oor, including closets and storage spaces, through which the vertical fl ue passes, must be enclosed.

CATHEDRAL CEILINGS

Round Support (RDS) & Square Support (SQS)

If your home has a cathedral ceiling (no attic space between the ceiling and the roof), install the chimney and support as follows.

Using a level, make sure the support is vertical. If the support extends above the roof, cut it fl ush with the top of the roof. Nailthesupporttotheframeopeningusing

(8) 3" spiral nails or #8 x 1-1/2" screws.

Note: If you are using a 6" square support you may find it difficult to screw it in place because it is fairly small inside.

Simpson Dura-Flue has provided angle brackets with this support which can be screwed to the outside of the support box and nailed to surrounding framing as required. Use a minimum of four #8 x 1/2" screws per bracket. In some cases these brackets may need to be trimmed (e.g.: to fit under a fl ashing). Place the Finish Collar around the support and fasten it to the ceiling using the screws provided.

3)Use appropriate roof fl ashing. Place the fl ashing under the upper shingles and on top of the lower shingles approximately half of the fl ashing should be under the shingles.

4)AssemblethedesiredlengthsofBlackPipe and Elbows necessary to reach from the appliance adaptor up through the support box and fl ashing to proper height as per Dia. 12, local codes or page 9. Ensure that all pipe and elbow connections are in their fully twist lock position.

5)Ensure fl ue is vertical and secure fl ashing to the roof with roofi ng nails. Slide the storm collar over the pipe section and seal with a mastic.

installation codes.

When using copper or fl ex connectors use only approved fi ttings. Always provide a union so that gas lines can be easily disconnected for burner and/or valve servicing. Flare nuts for copper lines and fl ex connectors are usually considered to meet this requirement.

Important:Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open flame for leak testing.

Note: Prior to any pressure testing of the gas supply piping system that exceeds test pressures of 3.45 kPa, this appliance must be disconnected from the piping system. If test pres- sures equal to or less than 3.45 kPa are used then this appliance must be isolated from the piping system by closingitsindividualmanualshut-off valve during the testing.

GAS PIPE PRESSURE

TESTING

Theappliancemustbeisolatedfromthegassup- plypipingsystembyclosingitsindividualmanual shut-off valve during any pressure testing of the gassupplypipingsystemattestpressuresequal to or less than 3.45 kPa. Disconnect piping from valve at pressures over 3.45 kPa.

The manifold pressure is controlled by a regu- lator built into the gas control, and should be checked at the pressure test point.

Regency® F39 Room Sealed Freestanding Gas Stove

15

Image 15
Contents 05/18/06 Please Keep These Instructions For Future ReferenceRegency F39 Room Sealed Freestanding Gas Stove Unit SpecificationsTable of Contents Safety Label Before YOU Start InstallationSpecifications General Safety InformationInstallation Checklist Clearances to CombustiblesLocating Your Regency GAS Stove Flueing Introduction Louver InstallationInstallation Precautions Safety Precautions For the InstallerExterior Flue Termination Locations Clearance k in mmSpace Heaters Fluing Arrangements Horizontal Terminations for All Fluing SystemsFlue Restrictor Position Optional DV Stove Horizontal Flue KIT # 946-112 InstallationDV Stove Horizontal Flue KIT Qty. DescriptionInstallation DURA-FLUE Fluing Components Planning Your Dura-Flue InstallationMinimum components for a Dura-Flue Horizontal Installation DURA-FLUE Termination KITView as possible. DURA-FLUE Horizontal Installations988 Wall Strap 942 Wall Thimble Pipe and elbows to the ap- pliance adaptor withHole previously drilled in the ceiling, and mark DURA-FLUE Vertical TerminationCathedral Ceilings GAS Pipe Pressure TestingOffset Chart GAS ConnectionSystem Data Aeration AdjustmentValve Description System Data F39 with 40mjConversion Kit Contains Qty Description Conversion KIT #731-968 from NG to LPGConversion to Lower BTU Rating LOG SET InstallationPlace the Middle Left Log B02-56 on the two pins as shown Place Front Right Log E02-45 on the two pins as shownPlace Front Left Log C02-44 onto Final Check Front Door InstallationOptional Remote Control Optional Wall ThermostatWiring Operating Instructions Normal Operating Sounds of GAS Appliances Copy of the Lighting Plate InstructionsGOLD-PLATED Doors MaintenanceMaintenance Instructions General Flue MaintenanceDoor Gasket LOG ReplacementLatch Adjustment Glass ReplacementReplacing F39 Fan FAN MaintenanceAlternate Fan Access To remove F39 fanRemoving Valve Part# Description Parts ListF39 Main Assembly DescriptionF39 Burner & LOG Assembly 936-243 Glass Gasket 650-920 Door Gasket KitCeramic Paper 940-323/P Side GlassWarranty Lifetime Warranty

F39-LPG, F39-NG specifications

The Regency F39-LPG and F39-NG are contemporary gas fireplaces that have garnered attention for their stylish design and advanced technology. These models cater to homeowners seeking an efficient and visually appealing heating solution. Designed with both function and aesthetics in mind, the F39 series stands out for its elegant linear design, making it suitable for a variety of interior styles.

One of the distinguishing features of the F39 series is its commitment to energy efficiency. Both the F39-LPG, which operates on liquid propane, and the F39-NG, which utilizes natural gas, have been engineered to deliver optimal heat output while consuming minimal fuel. This efficiency not only reduces energy costs but also minimizes environmental impact, aligning with modern sustainable living practices.

The F39 series boasts advanced venting technology, allowing for versatile installation options. This feature enables homeowners to select the perfect location for their fireplace without compromising aesthetic appeal or functionality. The unit can be vented either vertically or horizontally, providing flexibility in design while ensuring safe and effective operation.

In terms of control, the Regency F39 models come equipped with a user-friendly remote control option. This allows for convenient operation from across the room, making it easy to adjust flame height and heat settings to create the perfect ambiance. Moreover, the models can also be connected to smart home systems, enabling homeowners to integrate their fireplace into a broader heating management system.

Aesthetically, the F39 series offers customizable options, including various media and decorative elements. Homeowners can choose from traditional logs, contemporary glass, or pebbles, allowing each unit to reflect their personal style and complement their home’s decor. The large glass viewing area enhances the visual experience, showcasing the beautiful flame patterns that add warmth and character to any room.

Durability is also a significant aspect of the design, with high-quality materials that ensure longevity and performance. The F39-LPG and F39-NG are constructed to withstand the rigors of everyday use while maintaining their sleek appearance.

In summary, the Regency F39-LPG and F39-NG fireplaces represent a blend of efficiency, technology, and elegance. With their advanced features, customizable aesthetics, and environmentally friendly operation, these models are ideal for those looking to enhance their living spaces with both warmth and style. Whether for a modern home or a more traditional setting, the F39 series is designed to meet diverse heating needs while providing a stunning focal point in any room.