Regency F39-LPG DURA-FLUE Horizontal Installations, Wall Strap 942 Wall Thimble, View as possible

Page 13

INSTALLATION

945B

45O Elbow-Black

945G

45O Elbow-Swivel Galv.

945BG

45O Elbow-Swivel-Black

990

90O Elbow Galv.

990B

90O Elbow-Black

990G

90O Elbow-Swivel Galv.

990BG

90O Elbow-Swivel-Black

991

High Wind Term. Cap (Vertical)

980

Vertical Term. Cap

982

Snorkel-14" Rise Term.Cap

981

Snorkel-36" Rise Term.Cap

940Wall Thimble-Support/Box

941Cathedral/Ceiling-Support/Box

3951 Brass Trim-Wall Thimble/ Ceiling Support

963

Firestop Spacer

943Flashing 0/12-6/12

943S Flashing 7/12-12/12

953

Storm Collar

950

Vinyl Siding Standoff

988

Wall Strap

942

Wall Thimble

Parts not supplied by Dura-Flue 946-506/P Flue Guard (Optional)

DURA-FLUE

HORIZONTAL

INSTALLATIONS

1)Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the fl uing system is attached. If this is the case, you may want to adjust the location of the unit.

2)Room Sealed pipe and fi ttings are designed with special twist-lock connections to con- nect the fl uing system to the appliance fl ue outlet. A twist-lock appliance adaptor is installed on the unit at the factory.Assemble the desired combination of

pipe and elbows to the ap- pliance adaptor with

pipe seams oriented towards the wall or ceiling, as much out of

view as possible. The

nal positioning of the pipe and 90o elbow as- sembly is determined by the mounting

orientationofthe adaptor on the stove and twist- lockedforasolid connection.

Note:

a)Twist-lockprocedure:Fourindentations, located on the female ends of pipes and fi ttings, are designed to slide straight onto the male ends of adjacent pipes and fi ttings, by orienting the four pipe indentations so they match and slide in to the four entry slots on the male ends

(diagram 1). Push the pipe sections completely together, then twist-lock one section clockwise approximately one-quarter turn, until the two sections are fully locked. The female locking lugs will not be visible from the outside on the Black Pipe or fi ttings. They may be located by examining the inside of the female ends.Apply sealant "Mill-Pac" to innerpipeandhightempsiliconesealant to outer pipe on every twist-lock joint.

Hint: Apply silicone to female end.

b)Horizontalrunsoffluemustbesupported everythreefeet.Wallstrapsareavailable for this purpose.

3)With the pipe attached to the stove, slide the stove into its correct location, and mark the wall for a 10" x 10" (inside dimensions) square hole. The center of the square hole should line up with the centerline of the

Diagram 1

horizontal pipe, as shown in diagram 2. Cut and frame the 10 inch square hole in the exterior wall where the fl ue will be terminated. If the wall being penetrated is constructed of non-combustible material, i.e.masonryblockorconcrete,a7"diameter hole is acceptable.

Note:

a)The horizontal run of fl ue should have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the fl ue to run downward. This could cause high temperatures and may present the possibility of a fi re.

F39: 59-3/4" (1518mm)

Diagram 2

b)The location of the horizontal fl ue termi- nation on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. For External Flue Terminal Locations dia- gram, refer to "Exterior FlueTermination Location" section.

4)If installing the fl ue termination to a wall with vinyl siding, the Vinyl Siding Standoff must be used. Attach the Vinyl Siding Standoff to the Horizontal FlueTermination, but first run a bead of non-hardening mastic around its outsideedges,soastomakeasealbetween fl ue cap and the standoff. Install the Vinyl Siding Standoff (Part # 950) between the fl ue cap and the exterior wall and attach with the four wood screws provided. Seal around the Vinyl Siding Standoff on all four sides. Diagram 5. The arrow on the flue cap should be pointing up. Insure that the 1-1/4" clearances to combustible materials are maintained. See diagram 5.

 

Diagram 5

Note:

If installing termination on a siding

covered wall, a vinyl siding standoff or fur- ring strips must be used to ensure that the termination is not recessed into the siding. The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

5)Before connecting the horizontal run of fl ue pipe to the fl ue termination, slide the black decorative wall thimble cover over the fl ue pipe, then slide the Wall Thimble (Part # 942) over the fl ue pipe.

6)Slide the appliance and fl ue assembly towards the wall carefully inserting the fl ue pipe into the fl ue cap assembly. It is impor- tant that the fl ue pipe extends into the fl ue cap a suffi cient distance so as to result in a minimum pipe overlap of 1-1/4 inches. Secure the connection between the fl ue pipe and the fl ue cap using sheet metal screws provided. See diagram 6.

7)Install the Wall Thimble in the center of the 10" square and attach with wood screws.

Regency® F39 Room Sealed Freestanding Gas Stove

13

Image 13
Contents 05/18/06 Please Keep These Instructions For Future ReferenceRegency F39 Room Sealed Freestanding Gas Stove Unit SpecificationsTable of Contents Safety Label Specifications InstallationGeneral Safety Information Before YOU StartClearances to Combustibles Installation ChecklistLocating Your Regency GAS Stove Installation Precautions Louver InstallationSafety Precautions For the Installer Flueing IntroductionClearance k in mm Exterior Flue Termination LocationsSpace Heaters Horizontal Terminations for All Fluing Systems Fluing ArrangementsFlue Restrictor Position DV Stove Horizontal Flue KIT DV Stove Horizontal Flue KIT # 946-112 InstallationQty. Description OptionalInstallation Minimum components for a Dura-Flue Horizontal Installation Planning Your Dura-Flue InstallationDURA-FLUE Termination KIT DURA-FLUE Fluing Components988 Wall Strap 942 Wall Thimble DURA-FLUE Horizontal InstallationsPipe and elbows to the ap- pliance adaptor with View as possible.Hole previously drilled in the ceiling, and mark DURA-FLUE Vertical TerminationOffset Chart GAS Pipe Pressure TestingGAS Connection Cathedral CeilingsValve Description Aeration AdjustmentSystem Data F39 with 40mj System DataConversion Kit Contains Qty Description Conversion KIT #731-968 from NG to LPGConversion to Lower BTU Rating LOG SET InstallationPlace Front Right Log E02-45 on the two pins as shown Place the Middle Left Log B02-56 on the two pins as shownPlace Front Left Log C02-44 onto Optional Remote Control Front Door InstallationOptional Wall Thermostat Final CheckWiring Operating Instructions Normal Operating Sounds of GAS Appliances Copy of the Lighting Plate InstructionsMaintenance Instructions MaintenanceGeneral Flue Maintenance GOLD-PLATED DoorsLatch Adjustment LOG ReplacementGlass Replacement Door GasketAlternate Fan Access FAN MaintenanceTo remove F39 fan Replacing F39 FanRemoving Valve F39 Main Assembly Parts ListDescription Part# DescriptionF39 Burner & LOG Assembly Ceramic Paper 650-920 Door Gasket Kit940-323/P Side Glass 936-243 Glass GasketWarranty Lifetime Warranty

F39-LPG, F39-NG specifications

The Regency F39-LPG and F39-NG are contemporary gas fireplaces that have garnered attention for their stylish design and advanced technology. These models cater to homeowners seeking an efficient and visually appealing heating solution. Designed with both function and aesthetics in mind, the F39 series stands out for its elegant linear design, making it suitable for a variety of interior styles.

One of the distinguishing features of the F39 series is its commitment to energy efficiency. Both the F39-LPG, which operates on liquid propane, and the F39-NG, which utilizes natural gas, have been engineered to deliver optimal heat output while consuming minimal fuel. This efficiency not only reduces energy costs but also minimizes environmental impact, aligning with modern sustainable living practices.

The F39 series boasts advanced venting technology, allowing for versatile installation options. This feature enables homeowners to select the perfect location for their fireplace without compromising aesthetic appeal or functionality. The unit can be vented either vertically or horizontally, providing flexibility in design while ensuring safe and effective operation.

In terms of control, the Regency F39 models come equipped with a user-friendly remote control option. This allows for convenient operation from across the room, making it easy to adjust flame height and heat settings to create the perfect ambiance. Moreover, the models can also be connected to smart home systems, enabling homeowners to integrate their fireplace into a broader heating management system.

Aesthetically, the F39 series offers customizable options, including various media and decorative elements. Homeowners can choose from traditional logs, contemporary glass, or pebbles, allowing each unit to reflect their personal style and complement their home’s decor. The large glass viewing area enhances the visual experience, showcasing the beautiful flame patterns that add warmth and character to any room.

Durability is also a significant aspect of the design, with high-quality materials that ensure longevity and performance. The F39-LPG and F39-NG are constructed to withstand the rigors of everyday use while maintaining their sleek appearance.

In summary, the Regency F39-LPG and F39-NG fireplaces represent a blend of efficiency, technology, and elegance. With their advanced features, customizable aesthetics, and environmentally friendly operation, these models are ideal for those looking to enhance their living spaces with both warmth and style. Whether for a modern home or a more traditional setting, the F39 series is designed to meet diverse heating needs while providing a stunning focal point in any room.