Regency F39-NG FAN Maintenance, To remove F39 fan, Alternate Fan Access, Replacing F39 Fan

Page 26

MAINTENANCE

7)Tighten side panels nuts using the following procedure:

a.tighten top & bottom outside corner nuts

(2)

b.tighten inside nuts (3)

c.tighten top & bottom inside corners (2)

8)Tighten the 10 nuts on center glass re- tainer.

9)Repeat step 7 for other side panel.

10)Replace new gasket by gluing it in place.

11)Install door onto stove and check the seal.

To remove F39 fan:

1) Unplug or disconnect power source to stove.

2) Remove all logs and the rear log support, then remove the 10 screws holding the ac- cess panel in place.

3) Unclip the black and white wires from the

fan motor.

4)Open both side doors and gently pull the

fl ex pipe away from the center, otherwise the fan can catch on the fl ex pipe during installation and tear the pipe. Do not tear or damage the fl ex pipe.

FAN MAINTENANCE

Ifyourfanrequiresmaintenanceorreplacement, access to the fan is through the plate on the rear wall of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed.

If the fan is damaged or needs repair, it shall be repaired by the manufacturer or its service agent or similiarily qualified person to avoid a hazard.

IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan squirrel cages, around the motor, and around the grills on the back of the stove.

Alternate Fan Access:

If the rear access cover is ac- cessible, it can be removed to provide access to the fan.

Replacing F39 Fan:

Reverse the above steps (1 - 5). If necessary install a new gasket before replacing the fan access panel. Make sure the fan wires and the ground wire are reattached.

Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin. Check to make sure the fan is seated properly on the pins - try to move the fan back and forth, there should be no noise, if there is check that the grommets haven't come loose.

IMPORTANT

Disconnect power supply

before servicing

WARNING:

Electrical Grounding Instruc-

tions

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

5)Lift fan off of the 2 pins, tip back and pull through fi rebox opening. Disconnect the green ground wire from the right side of the fan as soon as you can reach it.

26

Regency® F39 Room Sealed Freestanding Gas Stove

Image 26
Contents Please Keep These Instructions For Future Reference 05/18/06Unit Specifications Regency F39 Room Sealed Freestanding Gas StoveTable of Contents Safety Label General Safety Information InstallationSpecifications Before YOU StartLocating Your Regency GAS Stove Installation ChecklistClearances to Combustibles Safety Precautions For the Installer Louver InstallationInstallation Precautions Flueing IntroductionSpace Heaters Exterior Flue Termination LocationsClearance k in mm Flue Restrictor Position Fluing ArrangementsHorizontal Terminations for All Fluing Systems Qty. Description DV Stove Horizontal Flue KIT # 946-112 InstallationDV Stove Horizontal Flue KIT OptionalInstallation DURA-FLUE Termination KIT Planning Your Dura-Flue InstallationMinimum components for a Dura-Flue Horizontal Installation DURA-FLUE Fluing ComponentsPipe and elbows to the ap- pliance adaptor with DURA-FLUE Horizontal Installations988 Wall Strap 942 Wall Thimble View as possible.DURA-FLUE Vertical Termination Hole previously drilled in the ceiling, and markGAS Connection GAS Pipe Pressure TestingOffset Chart Cathedral CeilingsSystem Data F39 with 40mj Aeration AdjustmentValve Description System DataConversion KIT #731-968 from NG to LPG Conversion Kit Contains Qty DescriptionLOG SET Installation Conversion to Lower BTU RatingPlace Front Left Log C02-44 onto Place the Middle Left Log B02-56 on the two pins as shownPlace Front Right Log E02-45 on the two pins as shown Optional Wall Thermostat Front Door InstallationOptional Remote Control Final CheckWiring Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesGeneral Flue Maintenance MaintenanceMaintenance Instructions GOLD-PLATED DoorsGlass Replacement LOG ReplacementLatch Adjustment Door GasketTo remove F39 fan FAN MaintenanceAlternate Fan Access Replacing F39 FanRemoving Valve Description Parts ListF39 Main Assembly Part# DescriptionF39 Burner & LOG Assembly 940-323/P Side Glass 650-920 Door Gasket KitCeramic Paper 936-243 Glass GasketWarranty Warranty Lifetime

F39-LPG, F39-NG specifications

The Regency F39-LPG and F39-NG are contemporary gas fireplaces that have garnered attention for their stylish design and advanced technology. These models cater to homeowners seeking an efficient and visually appealing heating solution. Designed with both function and aesthetics in mind, the F39 series stands out for its elegant linear design, making it suitable for a variety of interior styles.

One of the distinguishing features of the F39 series is its commitment to energy efficiency. Both the F39-LPG, which operates on liquid propane, and the F39-NG, which utilizes natural gas, have been engineered to deliver optimal heat output while consuming minimal fuel. This efficiency not only reduces energy costs but also minimizes environmental impact, aligning with modern sustainable living practices.

The F39 series boasts advanced venting technology, allowing for versatile installation options. This feature enables homeowners to select the perfect location for their fireplace without compromising aesthetic appeal or functionality. The unit can be vented either vertically or horizontally, providing flexibility in design while ensuring safe and effective operation.

In terms of control, the Regency F39 models come equipped with a user-friendly remote control option. This allows for convenient operation from across the room, making it easy to adjust flame height and heat settings to create the perfect ambiance. Moreover, the models can also be connected to smart home systems, enabling homeowners to integrate their fireplace into a broader heating management system.

Aesthetically, the F39 series offers customizable options, including various media and decorative elements. Homeowners can choose from traditional logs, contemporary glass, or pebbles, allowing each unit to reflect their personal style and complement their home’s decor. The large glass viewing area enhances the visual experience, showcasing the beautiful flame patterns that add warmth and character to any room.

Durability is also a significant aspect of the design, with high-quality materials that ensure longevity and performance. The F39-LPG and F39-NG are constructed to withstand the rigors of everyday use while maintaining their sleek appearance.

In summary, the Regency F39-LPG and F39-NG fireplaces represent a blend of efficiency, technology, and elegance. With their advanced features, customizable aesthetics, and environmentally friendly operation, these models are ideal for those looking to enhance their living spaces with both warmth and style. Whether for a modern home or a more traditional setting, the F39 series is designed to meet diverse heating needs while providing a stunning focal point in any room.