Beforeoperatingthisappliance,proceedthrough the following check list.

1)

Read and understand these Instructions

 

before operating this appliance.

2)

Check to see that all wiring is correct and

 

enclosed to prevent possible shock.

3)

Check to ensure there are no gas leaks.

4)

Make sure the three pieces of door glass

 

are properly positioned. Never operate the

 

appliance with any of the glass removed or

 

with the door open.

5)

Verify that all fl uing and the cap is unob-

 

structed.

6)

Verify log placement. If the pilot cannot be

 

seen when lighting the unit - the logs or the

4)Turn the PILOT knob counterclockwise to pilot and align it with the arrow as shown in diagram above.

5)Push in PILOT knob all the way in and hold. Immediately push IGNITOR button until pilot lights. Continue to hold the PILOT knob in for approximately one minute, then release the PILOT knob. The pilot fl ame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing PILOT knob.

6)Turn PILOT knob counter clockwise to on.

7)Use the Burner ON/OFF switch to turn on the burner.

8)Rotate the HEAT control to adjust the fl ame height higher or lower.

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and NEVER clean the glass while it is hot.

AUTOMATIC

CONVECTION

FAN OPERATION

Set the fan speed on control panel at the top rear of the unit to adjust to the desired speed. The fan will turn on as the stove comes up to operating temperature. After the unit has been turned off and the unit cooled to below a useful heat output range the fan will shut off automatically.

embers have been incorrectly positioned.

7) The unit should never to turned off and on

without a minimum of a 60 second wait.

LIGHTING

INSTRUCTIONS

IMPORTANT: The PILOT knob cannot be turned from pilot to off unless it is partially depressed.

Note: Open the pedestal door of the unit before lighting the pilot. Once the

SHUTDOWN

INSTRUCTIONS

1)Use the Burner ON/OFF switch, thermostat or remote control to turn off the burner.

2)Push in the PILOT knob slightly and turn clockwise to off. Do not force.

3)Turn off all electric power to the appliance if service is to be performed.

FIRST FIRE

ADJUSTING FLAME

HEIGHT

pilot is lit, close the door. You should never operate the unit with the door open.

1)If the PILOT knob is in the off position proceed to Step 4.

2)Push in PILOT knob slightly and turn clock- wisetooff. Knobcannotbeturnedfrom pilot to off unless knob is pushed in slightly. Do not force.

3)Wait fi ve minutes to allow gas, that may have accumulated in the main burner compartment, to escape. If you smell gas, follow the instructions on the front of this manual. If you don't smell gas continue on to the next step.

The FIRST FIRE in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the fi rst time you use it with the fan on. When fi rst oper- ated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!

Note: When the glass is cold and the appli- ance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

Your heater has an adjustable fl ame to tailor the look and heat output to your specific needs. It is adjusted by turning the fl ame adjustment dial on the gas control valve.

Turn clockwise to adjust the fl ame higher, counterclockwise for a lower fl ame.

22

Regency® F39 Room Sealed Freestanding Gas Stove

Image 22
Contents Please Keep These Instructions For Future Reference 05/18/06Unit Specifications Regency F39 Room Sealed Freestanding Gas StoveTable of Contents Safety Label General Safety Information InstallationSpecifications Before YOU StartClearances to Combustibles Installation ChecklistLocating Your Regency GAS Stove Safety Precautions For the Installer Louver InstallationInstallation Precautions Flueing IntroductionClearance k in mm Exterior Flue Termination LocationsSpace Heaters Horizontal Terminations for All Fluing Systems Fluing ArrangementsFlue Restrictor Position Qty. Description DV Stove Horizontal Flue KIT # 946-112 InstallationDV Stove Horizontal Flue KIT OptionalInstallation DURA-FLUE Termination KIT Planning Your Dura-Flue InstallationMinimum components for a Dura-Flue Horizontal Installation DURA-FLUE Fluing ComponentsPipe and elbows to the ap- pliance adaptor with DURA-FLUE Horizontal Installations988 Wall Strap 942 Wall Thimble View as possible.DURA-FLUE Vertical Termination Hole previously drilled in the ceiling, and markGAS Connection GAS Pipe Pressure TestingOffset Chart Cathedral CeilingsSystem Data F39 with 40mj Aeration AdjustmentValve Description System DataConversion KIT #731-968 from NG to LPG Conversion Kit Contains Qty DescriptionLOG SET Installation Conversion to Lower BTU RatingPlace Front Right Log E02-45 on the two pins as shown Place the Middle Left Log B02-56 on the two pins as shownPlace Front Left Log C02-44 onto Optional Wall Thermostat Front Door InstallationOptional Remote Control Final CheckWiring Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesGeneral Flue Maintenance MaintenanceMaintenance Instructions GOLD-PLATED DoorsGlass Replacement LOG ReplacementLatch Adjustment Door GasketTo remove F39 fan FAN MaintenanceAlternate Fan Access Replacing F39 FanRemoving Valve Description Parts ListF39 Main Assembly Part# DescriptionF39 Burner & LOG Assembly 940-323/P Side Glass 650-920 Door Gasket KitCeramic Paper 936-243 Glass GasketWarranty Warranty Lifetime

F39-LPG, F39-NG specifications

The Regency F39-LPG and F39-NG are contemporary gas fireplaces that have garnered attention for their stylish design and advanced technology. These models cater to homeowners seeking an efficient and visually appealing heating solution. Designed with both function and aesthetics in mind, the F39 series stands out for its elegant linear design, making it suitable for a variety of interior styles.

One of the distinguishing features of the F39 series is its commitment to energy efficiency. Both the F39-LPG, which operates on liquid propane, and the F39-NG, which utilizes natural gas, have been engineered to deliver optimal heat output while consuming minimal fuel. This efficiency not only reduces energy costs but also minimizes environmental impact, aligning with modern sustainable living practices.

The F39 series boasts advanced venting technology, allowing for versatile installation options. This feature enables homeowners to select the perfect location for their fireplace without compromising aesthetic appeal or functionality. The unit can be vented either vertically or horizontally, providing flexibility in design while ensuring safe and effective operation.

In terms of control, the Regency F39 models come equipped with a user-friendly remote control option. This allows for convenient operation from across the room, making it easy to adjust flame height and heat settings to create the perfect ambiance. Moreover, the models can also be connected to smart home systems, enabling homeowners to integrate their fireplace into a broader heating management system.

Aesthetically, the F39 series offers customizable options, including various media and decorative elements. Homeowners can choose from traditional logs, contemporary glass, or pebbles, allowing each unit to reflect their personal style and complement their home’s decor. The large glass viewing area enhances the visual experience, showcasing the beautiful flame patterns that add warmth and character to any room.

Durability is also a significant aspect of the design, with high-quality materials that ensure longevity and performance. The F39-LPG and F39-NG are constructed to withstand the rigors of everyday use while maintaining their sleek appearance.

In summary, the Regency F39-LPG and F39-NG fireplaces represent a blend of efficiency, technology, and elegance. With their advanced features, customizable aesthetics, and environmentally friendly operation, these models are ideal for those looking to enhance their living spaces with both warmth and style. Whether for a modern home or a more traditional setting, the F39 series is designed to meet diverse heating needs while providing a stunning focal point in any room.