Regency F39-NG, F39-LPG Aeration Adjustment, Valve Description, System Data F39 with 40mj

Page 16

INSTALLATION

Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.

1)Make sure the valve is in the "OFF" posi- tion.

2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide fl at screwdriver.

3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.

4)Light the pilot and turn the valve to "ON" position. Read manometer.

5)The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label.

6)When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. Note: Screw should be snug, but do not over tighten

Valve Description

1)Gas on/off knob

2)Manual high/low adjustment

3)Pilot Adjustment

4)Thermocouple Connection

5)Main Operator

6)Outlet Pressure Tap (Manifold Pressure)

7)Inlet Pressure Tap (Supply Pressure)

8)Pilot Outlet

9)Main Gas Outlet

10)Flange Securing Screw Holes

11)Alternative TC Connection Point

12)Thermoelectric Unit

13)Additional Valve Mounting Hole

System Data

F39 with 40mj

Burner Inlet Orifi ce Sizes:

NG LPG

Burner #32 #50 2.95mm 1.78mm

Max. Input

NG

40 Mj/h

 

LPG

38 Mj/h

Min. Input

NG

20 Mj/h

 

LPG

19 Mj/h

 

 

Supply Pressure

 

NG

 

min. 1.13 kPa

LPG

 

min. 2.75 kPa

Manifold Pressure

NG .94 kPa

LPG 2.55kPa

Electrical: 240 V. 1.13A 60Hz.

Circulation: 2 speed fan, 125/75 CFM.

Log Set: Ceramic fi ber, 7 per set.

 

System Data

F39 Converted to 31mj

 

 

Burner Inlet Orifi ce Sizes:

 

NG

#37

2.65mm

LPG

#52

1.6mm

Max. Input - NG/LPG

31 Mj/h

Min. Input - NG/LPG

16 Mj/h

Supply Pressure

 

NG

min. 1.13 kPa

LPG

min. 2.75 kPa

 

 

Manifold Pressure

 

NG

.89 kPa

LPG

2.55kPa

Electrical: 240 V. 1.13A 60Hz.

Circulation: Variable speed fan, 125/75 CFM.

Log Set: Ceramic fi ber, 7 per set.

AERATION

ADJUSTMENT

The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

 

F39 with 40mj

 

F39-NG

NG:

Full open

F39-LPG

LPG:

Full open

 

F39 with 31mj

 

F39-NG

NG

6mm open

F39-LPG

LPG

10mm open

Note: Anydamageduetocarboningresulting from improperly setting the aeration controls is NOT covered under war- ranty.

16

Regency® F39 Room Sealed Freestanding Gas Stove

Image 16
Contents Please Keep These Instructions For Future Reference 05/18/06Unit Specifications Regency F39 Room Sealed Freestanding Gas StoveTable of Contents Safety Label Installation SpecificationsGeneral Safety Information Before YOU StartClearances to Combustibles Installation ChecklistLocating Your Regency GAS Stove Louver Installation Installation PrecautionsSafety Precautions For the Installer Flueing IntroductionClearance k in mm Exterior Flue Termination LocationsSpace Heaters Horizontal Terminations for All Fluing Systems Fluing ArrangementsFlue Restrictor Position DV Stove Horizontal Flue KIT # 946-112 Installation DV Stove Horizontal Flue KITQty. Description OptionalInstallation Planning Your Dura-Flue Installation Minimum components for a Dura-Flue Horizontal InstallationDURA-FLUE Termination KIT DURA-FLUE Fluing ComponentsDURA-FLUE Horizontal Installations 988 Wall Strap 942 Wall ThimblePipe and elbows to the ap- pliance adaptor with View as possible.DURA-FLUE Vertical Termination Hole previously drilled in the ceiling, and markGAS Pipe Pressure Testing Offset ChartGAS Connection Cathedral CeilingsAeration Adjustment Valve DescriptionSystem Data F39 with 40mj System DataConversion KIT #731-968 from NG to LPG Conversion Kit Contains Qty DescriptionLOG SET Installation Conversion to Lower BTU RatingPlace Front Right Log E02-45 on the two pins as shown Place the Middle Left Log B02-56 on the two pins as shownPlace Front Left Log C02-44 onto Front Door Installation Optional Remote ControlOptional Wall Thermostat Final CheckWiring Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance Maintenance InstructionsGeneral Flue Maintenance GOLD-PLATED DoorsLOG Replacement Latch AdjustmentGlass Replacement Door GasketFAN Maintenance Alternate Fan AccessTo remove F39 fan Replacing F39 FanRemoving Valve Parts List F39 Main AssemblyDescription Part# DescriptionF39 Burner & LOG Assembly 650-920 Door Gasket Kit Ceramic Paper940-323/P Side Glass 936-243 Glass GasketWarranty Warranty Lifetime

F39-LPG, F39-NG specifications

The Regency F39-LPG and F39-NG are contemporary gas fireplaces that have garnered attention for their stylish design and advanced technology. These models cater to homeowners seeking an efficient and visually appealing heating solution. Designed with both function and aesthetics in mind, the F39 series stands out for its elegant linear design, making it suitable for a variety of interior styles.

One of the distinguishing features of the F39 series is its commitment to energy efficiency. Both the F39-LPG, which operates on liquid propane, and the F39-NG, which utilizes natural gas, have been engineered to deliver optimal heat output while consuming minimal fuel. This efficiency not only reduces energy costs but also minimizes environmental impact, aligning with modern sustainable living practices.

The F39 series boasts advanced venting technology, allowing for versatile installation options. This feature enables homeowners to select the perfect location for their fireplace without compromising aesthetic appeal or functionality. The unit can be vented either vertically or horizontally, providing flexibility in design while ensuring safe and effective operation.

In terms of control, the Regency F39 models come equipped with a user-friendly remote control option. This allows for convenient operation from across the room, making it easy to adjust flame height and heat settings to create the perfect ambiance. Moreover, the models can also be connected to smart home systems, enabling homeowners to integrate their fireplace into a broader heating management system.

Aesthetically, the F39 series offers customizable options, including various media and decorative elements. Homeowners can choose from traditional logs, contemporary glass, or pebbles, allowing each unit to reflect their personal style and complement their home’s decor. The large glass viewing area enhances the visual experience, showcasing the beautiful flame patterns that add warmth and character to any room.

Durability is also a significant aspect of the design, with high-quality materials that ensure longevity and performance. The F39-LPG and F39-NG are constructed to withstand the rigors of everyday use while maintaining their sleek appearance.

In summary, the Regency F39-LPG and F39-NG fireplaces represent a blend of efficiency, technology, and elegance. With their advanced features, customizable aesthetics, and environmentally friendly operation, these models are ideal for those looking to enhance their living spaces with both warmth and style. Whether for a modern home or a more traditional setting, the F39 series is designed to meet diverse heating needs while providing a stunning focal point in any room.