Regency F39-NG, F39-LPG installation manual DURA-FLUE Termination KIT, DURA-FLUE Fluing Components

Page 12

INSTALLATION

DURA-FLUE

TERMINATION KIT

Planning Your Dura-Flue

Installation

There are two basic types of Dura-Flue Room Sealed System installations: horizontal termi-

Note: These are the minimum pieces re- quired. Other parts may be required for your particular installation. See page 12 for a list of flue parts.

If installing termination on a siding covered wall, a vinyl siding standoff or furring strips can be used in order to ensure that the termination is not recessed into siding.

and fi ttings are used for concealed locations such as attics or where corrosion is a factor, such as above the roof line. Decorative brass trim kits are available for both wall thimbles and ceiling support boxes.

Part #

Description

971Horiz. Termination Kit includes:

90o

nation and vertical termination. Confi rm the maximum horizontal run and maximum vertical rise from the diagrams, refer to "FluingArrange-

The vinyl siding standoff is required for walls

black elbow, wall thimble cover,

with vinyl siding.

horiz. square termination cap,

 

24"

ments" section.

When planning your installation, it will be nec- essary to select the proper length of fl ue pipe for your particular requirements. For horizontal installations, determine the minimum clearance from the rear of the unit to the wall. It is also important to note the wall thickness. (The wall thimble is suitable for 2 x 4 or 2 x 6 wall construc- tion.) Select the amount of vertical rise desired for "vertical-to-horizontal" type installations.

Warning: Always maintain required clear- ances (air spaces) to nearby combustibles to prevent a fire hazard. Do not fill air spaces with insulation.

The minimum clearance requirements between the outer wall of the fl ue pipe and nearby com- bustible surfaces is 1-1/4 inch. Be sure to check the fl ue termination clearance requirements from decks, windows, soffi ts, gas regulators, air supply inlets and public walkways as specifi ed in the Exterior Flue Terminal Locations on page 8 and in your local building codes.

Minimum components for a Dura-Flue Horizontal

Installation:

A)Dura-Flue Horizontal Termination Kit

B)Wall Thimble (required for combus- tible walls)

Minimum components for a Dura-Flue Verti- cal Termination:

C)Dura-Flue Vertical Termination Kit See page 12 for pipe lengths.

The Simpson Dura-Flue Room Sealed System offers a complete line of component parts for installationofbothhorizontalandverticalinstalla- tion. Many items are offered in decorative black, as well as galvanized finish.The galvanized pipe

Vertical

Terminal

Storm Collar

Part # 953

black pipe, 11" -14" 5/8" adjust-

able

black pipe

970Basic Horiz. Termination Kit includes: 90o black elbow, wall thimble cover, horiz. square

termination cap

978Vert. Termination Kit includes 0/12 - 6/12 pitch adjustable

fl ashing, storm collar, low profi le term. cap

908B 6" Pipe Length-Black

907B 9" Pipe Length-Black

90612" Pipe Length Galv.

906B 12" Pipe Length-Black

90424" Pipe Length Galv.

904B 24" Pipe Length-Black

90336" Pipe Length Galv.

903B 36" Pipe Length-Black

90248" Pipe Length Galv.

902B 48" Pipe Length-Black

911B 11"-14 5/8" Adj. Pipe Length- Black

917B

17"- 24" Adj. Pipe Length Black

945

45O Elbow Galv.

To determine the length of fl ue pipe required for vertical installations, measure the distance from the unit fl ue outlet to the ceiling, the ceiling thickness, the vertical rise in an attic or second storey, and allow for suffi cient vertical height above the roof line.

For multi-storey applications, fi re stops are required at each fl oor level. If an offset is needed, additional pipe, elbows and supports will be required.

Do not exceed the maximum number of elbows. One 90o for horizontal terminations and two 45o for vertical termination.

DURA-FLUE FLUING

COMPONENTS

You will require the following components with your new Regency® Room Sealed Freestand- ing Gas Stove. Please review your product to make sure you have everything you need. In the efl ue that you are missing any part, contact your dealer.

Flashing

 

Vinyl Siding

 

 

Standoff (Optional)

 

 

943 or 943S

 

 

 

Part #950

 

 

 

Round

 

 

 

 

 

 

Ceiling Firestop

Support Box/

 

 

 

(Part # 963)

Wall Thimble

 

 

 

 

(Part # 940)

 

 

AstroCap

 

 

 

 

Round Support

 

 

Termination Cap

 

 

(Part# 946-523)

Box/Wall Thimble

 

 

 

 

 

 

(Part # 940)

 

Wall Thimble

 

 

 

 

 

 

Part # 942

 

Pipe Length

Adj.Pipe Length

 

 

 

11" - 14-5/8"

 

Dura-Flue Basic

 

(279mm - 372mm)

 

 

90o Elbow

 

 

Horizontal Kit # 970

 

 

 

1

90o Elbow

 

 

 

1

Wall Thimble Cover

 

24" (610mm)

 

1

Astro Cap

 

Pipe Length

 

 

 

 

 

12

Regency® F39 Room Sealed Freestanding Gas Stove

Image 12
Contents Please Keep These Instructions For Future Reference 05/18/06Unit Specifications Regency F39 Room Sealed Freestanding Gas StoveTable of Contents Safety Label Installation SpecificationsGeneral Safety Information Before YOU StartInstallation Checklist Clearances to CombustiblesLocating Your Regency GAS Stove Louver Installation Installation PrecautionsSafety Precautions For the Installer Flueing IntroductionExterior Flue Termination Locations Clearance k in mmSpace Heaters Fluing Arrangements Horizontal Terminations for All Fluing SystemsFlue Restrictor Position DV Stove Horizontal Flue KIT # 946-112 Installation DV Stove Horizontal Flue KITQty. Description OptionalInstallation Planning Your Dura-Flue Installation Minimum components for a Dura-Flue Horizontal InstallationDURA-FLUE Termination KIT DURA-FLUE Fluing ComponentsDURA-FLUE Horizontal Installations 988 Wall Strap 942 Wall ThimblePipe and elbows to the ap- pliance adaptor with View as possible.DURA-FLUE Vertical Termination Hole previously drilled in the ceiling, and markGAS Pipe Pressure Testing Offset ChartGAS Connection Cathedral CeilingsAeration Adjustment Valve DescriptionSystem Data F39 with 40mj System DataConversion KIT #731-968 from NG to LPG Conversion Kit Contains Qty DescriptionLOG SET Installation Conversion to Lower BTU RatingPlace the Middle Left Log B02-56 on the two pins as shown Place Front Right Log E02-45 on the two pins as shownPlace Front Left Log C02-44 onto Front Door Installation Optional Remote ControlOptional Wall Thermostat Final CheckWiring Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance Maintenance InstructionsGeneral Flue Maintenance GOLD-PLATED DoorsLOG Replacement Latch AdjustmentGlass Replacement Door GasketFAN Maintenance Alternate Fan AccessTo remove F39 fan Replacing F39 FanRemoving Valve Parts List F39 Main AssemblyDescription Part# DescriptionF39 Burner & LOG Assembly 650-920 Door Gasket Kit Ceramic Paper940-323/P Side Glass 936-243 Glass GasketWarranty Warranty Lifetime

F39-LPG, F39-NG specifications

The Regency F39-LPG and F39-NG are contemporary gas fireplaces that have garnered attention for their stylish design and advanced technology. These models cater to homeowners seeking an efficient and visually appealing heating solution. Designed with both function and aesthetics in mind, the F39 series stands out for its elegant linear design, making it suitable for a variety of interior styles.

One of the distinguishing features of the F39 series is its commitment to energy efficiency. Both the F39-LPG, which operates on liquid propane, and the F39-NG, which utilizes natural gas, have been engineered to deliver optimal heat output while consuming minimal fuel. This efficiency not only reduces energy costs but also minimizes environmental impact, aligning with modern sustainable living practices.

The F39 series boasts advanced venting technology, allowing for versatile installation options. This feature enables homeowners to select the perfect location for their fireplace without compromising aesthetic appeal or functionality. The unit can be vented either vertically or horizontally, providing flexibility in design while ensuring safe and effective operation.

In terms of control, the Regency F39 models come equipped with a user-friendly remote control option. This allows for convenient operation from across the room, making it easy to adjust flame height and heat settings to create the perfect ambiance. Moreover, the models can also be connected to smart home systems, enabling homeowners to integrate their fireplace into a broader heating management system.

Aesthetically, the F39 series offers customizable options, including various media and decorative elements. Homeowners can choose from traditional logs, contemporary glass, or pebbles, allowing each unit to reflect their personal style and complement their home’s decor. The large glass viewing area enhances the visual experience, showcasing the beautiful flame patterns that add warmth and character to any room.

Durability is also a significant aspect of the design, with high-quality materials that ensure longevity and performance. The F39-LPG and F39-NG are constructed to withstand the rigors of everyday use while maintaining their sleek appearance.

In summary, the Regency F39-LPG and F39-NG fireplaces represent a blend of efficiency, technology, and elegance. With their advanced features, customizable aesthetics, and environmentally friendly operation, these models are ideal for those looking to enhance their living spaces with both warmth and style. Whether for a modern home or a more traditional setting, the F39 series is designed to meet diverse heating needs while providing a stunning focal point in any room.