Regency F39-NG, F39-LPG DV Stove Horizontal Flue KIT # 946-112 Installation, Qty. Description

Page 10

INSTALLATION

DV STOVE HORIZONTAL FLUE KIT

Horizontal Stove Flue Kit (Part # 946-112) includes all the parts needed to install the F39 Freestand- ing Gas unit with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown in your manual.

Qty. Description

1)2 Rigid Pipe Section 1.2m length, 165mm inside diameter

2)

 

1

Flex Liner, compressed aluminium 2 ply liner, 102mm inside diameter

3)

 

4 spring spacers

4)

 

1

90 deg. Elbow

5)

 

1

Decorative Wall Trim

 

 

 

 

6)

 

1 Adapter

 

 

7)

1

 

AstroCap Termination Cap

8)

2

 

Trim Collar

9)

1

 

tube of Mill-Pac, high temperature sealant

10)

12 Screws, #8 x 1/2" Self tapping, Stainless Steel

11)14 Screws, #8 x 1/2" Self tapping, Black

12) 4 Screws #8 x 1-1/2" Drill Point, Stainless Steel

Optional:

946-206 Vinyl Siding Standoff

for AstroCap

Note:

a)Liner sections should be continuous without any joints or seams.

b)This is an approved system, therefore components in this system must not be substituted for any other manufacturer's products.

c)Wall Thimble is required when installing through a combustible wall.

DV STOVE HORIZONTAL FLUE KIT (# 946-112) INSTALLATION

Review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thick- ness. Refer to flue location, see "Exterior

Flue Termination Location" section. and clearance dimensions, see to "Clearances to Combustibles" section.

1)Set the unit in its desired location. Check to determine if wall studs will be in the way of the fl uing system, adjust location until all clearances are met and there are no obstructions.

Note: A 1-1/2"(38mm) clearance around the outer pipe must be maintained except that only a 1" (25mm) clear- ance is needed at the termination end.

IMPORTANT:

Do not locate termination hood where excessive snow or ice buildup may occur. Be sure to check flue termination area after snow falls, and clear to prevent accidental blockage of fluing system. When using

F39: 59-3/4" ( 1518mm)

Minimum Installation Height:

snowblowers,makesuresnowisnotdirected towards flue termination area.

2)Assemble a trial fit to determine the verti- cal center-line for the fl ue termination.

a)Cut a 241mm round hole on both the interior and exterior wall.

b)Attach the 2 ft. pipe section to the fl ue terminal and slide into position from theexterior.Thelargerdiameterend of the adjustable pipe goes to the flue terminal.

c)Install the 90o elbow onto the adjust- able pipe to determine the vertical centerline of the starter collar on the unit.

Note: if the centerline cannot be met, the adjustable sections will have to be cut.

d)Cut the 2 ft. section of rigid pipe to length. Ensure that the pipe length

10

Regency® F39 Room Sealed Freestanding Gas Stove

Image 10
Contents Please Keep These Instructions For Future Reference 05/18/06Unit Specifications Regency F39 Room Sealed Freestanding Gas StoveTable of Contents Safety Label General Safety Information InstallationSpecifications Before YOU StartClearances to Combustibles Installation ChecklistLocating Your Regency GAS Stove Safety Precautions For the Installer Louver InstallationInstallation Precautions Flueing IntroductionClearance k in mm Exterior Flue Termination LocationsSpace Heaters Horizontal Terminations for All Fluing Systems Fluing ArrangementsFlue Restrictor Position Qty. Description DV Stove Horizontal Flue KIT # 946-112 InstallationDV Stove Horizontal Flue KIT OptionalInstallation DURA-FLUE Termination KIT Planning Your Dura-Flue InstallationMinimum components for a Dura-Flue Horizontal Installation DURA-FLUE Fluing ComponentsPipe and elbows to the ap- pliance adaptor with DURA-FLUE Horizontal Installations988 Wall Strap 942 Wall Thimble View as possible.DURA-FLUE Vertical Termination Hole previously drilled in the ceiling, and markGAS Connection GAS Pipe Pressure TestingOffset Chart Cathedral CeilingsSystem Data F39 with 40mj Aeration AdjustmentValve Description System DataConversion KIT #731-968 from NG to LPG Conversion Kit Contains Qty DescriptionLOG SET Installation Conversion to Lower BTU RatingPlace Front Right Log E02-45 on the two pins as shown Place the Middle Left Log B02-56 on the two pins as shownPlace Front Left Log C02-44 onto Optional Wall Thermostat Front Door InstallationOptional Remote Control Final CheckWiring Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesGeneral Flue Maintenance MaintenanceMaintenance Instructions GOLD-PLATED DoorsGlass Replacement LOG ReplacementLatch Adjustment Door GasketTo remove F39 fan FAN MaintenanceAlternate Fan Access Replacing F39 FanRemoving Valve Description Parts ListF39 Main Assembly Part# DescriptionF39 Burner & LOG Assembly 940-323/P Side Glass 650-920 Door Gasket KitCeramic Paper 936-243 Glass GasketWarranty Warranty Lifetime

F39-LPG, F39-NG specifications

The Regency F39-LPG and F39-NG are contemporary gas fireplaces that have garnered attention for their stylish design and advanced technology. These models cater to homeowners seeking an efficient and visually appealing heating solution. Designed with both function and aesthetics in mind, the F39 series stands out for its elegant linear design, making it suitable for a variety of interior styles.

One of the distinguishing features of the F39 series is its commitment to energy efficiency. Both the F39-LPG, which operates on liquid propane, and the F39-NG, which utilizes natural gas, have been engineered to deliver optimal heat output while consuming minimal fuel. This efficiency not only reduces energy costs but also minimizes environmental impact, aligning with modern sustainable living practices.

The F39 series boasts advanced venting technology, allowing for versatile installation options. This feature enables homeowners to select the perfect location for their fireplace without compromising aesthetic appeal or functionality. The unit can be vented either vertically or horizontally, providing flexibility in design while ensuring safe and effective operation.

In terms of control, the Regency F39 models come equipped with a user-friendly remote control option. This allows for convenient operation from across the room, making it easy to adjust flame height and heat settings to create the perfect ambiance. Moreover, the models can also be connected to smart home systems, enabling homeowners to integrate their fireplace into a broader heating management system.

Aesthetically, the F39 series offers customizable options, including various media and decorative elements. Homeowners can choose from traditional logs, contemporary glass, or pebbles, allowing each unit to reflect their personal style and complement their home’s decor. The large glass viewing area enhances the visual experience, showcasing the beautiful flame patterns that add warmth and character to any room.

Durability is also a significant aspect of the design, with high-quality materials that ensure longevity and performance. The F39-LPG and F39-NG are constructed to withstand the rigors of everyday use while maintaining their sleek appearance.

In summary, the Regency F39-LPG and F39-NG fireplaces represent a blend of efficiency, technology, and elegance. With their advanced features, customizable aesthetics, and environmentally friendly operation, these models are ideal for those looking to enhance their living spaces with both warmth and style. Whether for a modern home or a more traditional setting, the F39 series is designed to meet diverse heating needs while providing a stunning focal point in any room.